35 research outputs found

    Shoulder arthroplasty

    Get PDF
    Shoulder prostheses are now commonly used. Clinical results and patient satisfaction are usually good. The most commonly used types are humeral hemiarthroplasty, unconstrained total shoulder arthroplasty, and semiconstrained inversed shoulder prosthesis. Complications of shoulder arthroplasty depend on the prosthesis type used. The most common complications are prosthetic loosening, glenohumeral instability, periprosthetic fracture, rotator cuff tears, nerve injury, infection, and deltoid muscle dysfunction. Standard radiographs are the basis of both pre- and postoperative imaging. Skeletal scintigraphy has a rather limited role because there is overlap between postoperative changes which may persist for up to 1year and early loosening and infection. Sonography is most commonly used postoperatively in order to demonstrate complications (hematoma and abscess formation) but may also be useful for the demonstration of rotator cuff tears occurring during follow-up. CT is useful for the demonstration of bone details both pre- and postoperatively. MR imaging is mainly used preoperatively, for instance for demonstration of rotator cuff tear

    Swiss teleradiology survey: present situation and future trends

    Get PDF
    The purpose of this study was to obtain a survey about the present situation including the usage pattern, technical characteristics and the anticipated future of teleradiology in Switzerland. An internet-based questionnaire was made available to all members of the Swiss Society of Radiology. Questions concerning current teleradiology usage, the type of transmitted modalities, the technology employed, security, billing issues and the anticipated future of teleradiology were addressed. One hundred and two (22.67%) of 450 radiologists responded to the survey. Of the total, 41.2% (42) were teleradiology users, 35.3% (36) planned to use teleradiology in the near future and 24.5% (25) did not use or plan to use teleradiology. The mean number of examinations transmitted per month was 198 (range 1-2,000) and the mean distance was 33km (range 1,250km). An emergency service was considered the most important purpose (mean score 6.90; minimum 1, maximum 10) for the use of teleradiology, followed by image distribution (mean 6.74) and expert consultation (mean 6.61). The most commonly transmitted modality was computed tomography (mean 8.80), followed by conventional X-rays (8.40) and magnetic resonance imaging (8.32). The most commonly transmitted format was Digital Imaging and Communications in Medicine (DICOM) (66.7%), followed by bitmap/Joint Photographic Experts Group (jpg) (38.1%), using the DICOM send/receive protocol (52.4%), followed by the hypertext transfer protocol (26.2%) and e-mail (21.4%). For security a secure connection (54.8%) followed by encryption (14.3%) and anonymization (9.5%) was used. For the future, image distribution was rated the most important aspect of teleradiology (7.88), followed by emergency (7.22) and expert consultation (6.53). Development of legal regulations is considered most important (8.17), followed by data security guidelines (8.15). Most radiologists believe that insurance companies should pay for the costs of teleradiology (37.3%), followed by the radiologist (33.3%). In conclusion, in Switzerland a wide spectrum of teleradiology applications and technologies is in use. Guidelines and reimbursement issues remain to be solve

    MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    Get PDF
    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiograph

    Acromioclavicular joint cyst: nine cases of a pseudotumor of the shoulder

    Get PDF
    Objective: (1) To analyse the imaging appearances of nine patients with acromioclavicular joint cysts presenting as shoulder masses for tumor staging with operative, histopathological and joint aspiration findings. Design and patients: Retrospective review of imaging and correlation with clinical, operative and surgical notes. Images were reviewed by two musculoskeletal radiologists by consensus. Nine patients who presented clinically with a shoulder mass were evaluated by radiographs (n=9), ultrasound (n=1), conventional arthrography (n=3), MRI (n=6; with direct MR arthrography n=2, indirect MR arthrography n=4). Results: All patients had a focal mass superior to the AC joint, with a size ranging from 1.5cm to 6cm and a mean of 3.27cm. Correlation was available with surgery (n=7), histopathology (n=2) and cyst aspiration (n=2). Two patients were managed conservatively. Geyser sign was positive in all three arthrograms. All MRIs revealed extensive rotator cuff tears with a column of fluid extending from the glenohumeral joint through the rotator cuff tear into the acromioclavicular joint and acromioclavicular cyst. Chondrocalcinosis was seen in the acromioclavicular joint cyst (n=2) and in the glenohumeral joint (n=1). Aspirate in two patients contained calcium pyrophosphate dihydrate crystals. Conclusion: Acromioclavicular joint cysts may present as a tumor mass. They are associated with extensive rotator cuff tears and there is usually communication of the cyst with the joint space. This feature excludes a diagnosis of tumor. AC joint cysts may be associated with calcium pyrophosphate dihydrate deposition diseas

    Swiss teleradiology survey: present situation and future trends

    Full text link
    The purpose of this study was to obtain a survey about the present situation including the usage pattern, technical characteristics and the anticipated future of teleradiology in Switzerland. An internet-based questionnaire was made available to all members of the Swiss Society of Radiology. Questions concerning current teleradiology usage, the type of transmitted modalities, the technology employed, security, billing issues and the anticipated future of teleradiology were addressed. One hundred and two (22.67%) of 450 radiologists responded to the survey. Of the total, 41.2% (42) were teleradiology users, 35.3% (36) planned to use teleradiology in the near future and 24.5% (25) did not use or plan to use teleradiology. The mean number of examinations transmitted per month was 198 (range 1-2,000) and the mean distance was 33km (range 1,250km). An emergency service was considered the most important purpose (mean score 6.90; minimum 1, maximum 10) for the use of teleradiology, followed by image distribution (mean 6.74) and expert consultation (mean 6.61). The most commonly transmitted modality was computed tomography (mean 8.80), followed by conventional X-rays (8.40) and magnetic resonance imaging (8.32). The most commonly transmitted format was Digital Imaging and Communications in Medicine (DICOM) (66.7%), followed by bitmap/Joint Photographic Experts Group (jpg) (38.1%), using the DICOM send/receive protocol (52.4%), followed by the hypertext transfer protocol (26.2%) and e-mail (21.4%). For security a secure connection (54.8%) followed by encryption (14.3%) and anonymization (9.5%) was used. For the future, image distribution was rated the most important aspect of teleradiology (7.88), followed by emergency (7.22) and expert consultation (6.53). Development of legal regulations is considered most important (8.17), followed by data security guidelines (8.15). Most radiologists believe that insurance companies should pay for the costs of teleradiology (37.3%), followed by the radiologist (33.3%). In conclusion, in Switzerland a wide spectrum of teleradiology applications and technologies is in use. Guidelines and reimbursement issues remain to be solve

    Meeting the decision-making preferences of patients with breast cancer in oncology consultations: impact on decision-related outcomes

    No full text
    To investigate how involvement preferences of patients with breast cancer change during the treatment decision-making process and determine the impact of meeting patients' expectations on decision-making outcomes

    Model-Based System Engineering Framework for Superconducting Accelerator Magnet Design

    No full text
    The design specification of future high-field accelerator magnets require innovation in and integration of multiple disciplines. Numerical models underpin each step of the design. In this paper, we present a methodology for collaborative modeling based on relevant concepts of model-based systems engineering. The methodology is composed of three pillars: encapsulated computing environments with service query interface, model notebooks with auto-generated model views, and model query interface with results caching. The methodology aims at a de-centralized approach to multi-model and multi-scale collaboration that maintains the cornerstones of traceability and reproducibility. It is demonstrated with a multi-model coil design optimization of a high-field superconducting magnet

    MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    Full text link
    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiograph
    corecore