16 research outputs found
Near-field examination of perovskite-based superlenses and superlens-enhanced probe-object coupling
A planar slab of negative index material works as a superlens with
sub-diffraction-limited imaging resolution, since propagating waves are focused
and, moreover, evanescent waves are reconstructed in the image plane. Here, we
demonstrate a superlens for electric evanescent fields with low losses using
perovskites in the mid-infrared regime. The combination of near-field
microscopy with a tunable free-electron laser allows us to address precisely
the polariton modes, which are critical for super-resolution imaging. We
spectrally study the lateral and vertical distributions of evanescent waves
around the image plane of such a lens, and achieve imaging resolution of
wavelength/14 at the superlensing wavelength. Interestingly, at certain
distances between the probe and sample surface, we observe a maximum of these
evanescent fields. Comparisons with numerical simulations indicate that this
maximum originates from an enhanced coupling between probe and object, which
might be applicable for multifunctional circuits, infrared spectroscopy, and
thermal sensors.Comment: 20 pages, 6 figures, published as open access article in Nature
Communications (see http://www.nature.com/ncomms/
Silent dissemination of HTLV-1 in an endemic area of Argentina. Epidemiological and molecular evidence of intrafamilial transmission
Molecular and epidemiological studies of transmission routes and risk factors for infection by HTLV-1 are extremely important in order to implement control measures, especially because of the high prevalence of HTLV-1 in several regions of the world. San Salvador de Jujuy, Northwest Argentina, is a highly endemic area for HTLV-1 and foci of tropical spastic paraparesis/HTLV-1-associated myelopathy.To gain further insight into the role of intrafamilial transmission of HTLV-1 in a highly endemic region in Argentina.Cross-sectional study in Northwest Argentina. Epidemiological data and blood samples were collected from 28 HTLV-1 infected subjects (index cases) and 92 close relatives/cohabitants. HTLV-1 infection was diagnosed by detection of antibodies and proviral DNA. The LTR region was sequenced and analyzed for genetic distances (VESPA software), in addition to determination and identification of polymorphisms to define HTLV-1 family signatures.Fifty seven of the 120 subjects enrolled had antibodies against HTLV-1 and were typified as HTLV-1 by PCR. The prevalence rate of HTLV-1 infection in family members of infected index cases was 31.52% (29/92). The infection was significantly associated with gender, age and prolonged lactation. Identity of LTR sequences and presence of polymorphisms revealed high prevalence of mother-to-child and interspousal transmission of HTLV-1 among these families.There is an ongoing and silent transmission of HTLV-1 through vertical and sexual routes within family clusters in Northwest Argentina. This evidence highlights that HTLV-1 infection should be considered as a matter of public health in Argentina, in order to introduce preventive measures as prenatal screening and breastfeeding control
Optical nanoantennas
An overview of the field of optical plasmonic antennas is presented in this chapter. After a brief introduction and historical review, the theory of surface plasmon polaritons which leads to a set of overall observations as to the requirements and restrictions placed on the operation of plasmonic waveguides and antennas is presented. Both a single metal-dielectric interface and two interfaces between a metal sheet with dielectrics on either side are considered. In the second section the physical principles of operation and mathematical design criteria are presented for several common optical antennas including on-surface metallic structures and free standing particles. The third section covers the basic theory of aperture radiators along with a more detailed description of some popular designs. Current applications of optical nanoantennas are presented along with a discussion on some future directions in optical nanoantenna research
Evaluation of the use of real-time PCR for human T cell lymphotropic virus 1 and 2 as a confirmatory test in screening for blood donors Análise do uso da PCR em tempo real para HTLV-1 e 2 como teste confirmatório na triagem de doadores de sangue
INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.<br>INTRODUÇÃO: A triagem para HTLV-1/2 em doadores de sangue geralmente utiliza imunoensaio enzimático, seguido de um método confirmatório como Western blot quando o EIA é positivo, mas este algoritmo mostra alta taxa de resultados inconclusivos, e elevado custo. MÉTODOS: Dois ensaios qualitativos de PCR em tempo real foram desenvolvidos para detectar HTLV-1 e 2 e um total de 318 amostras foram testadas por PCR (152 de doadores de sangue, 108 de portadores assintomáticos, 26 de pacientes HAM/TSP e 30 de indivÃduos soronegativos). RESULTADOS: A sensibilidade e especificidade das PCR em relação aos resultados de WB foram de 99,4% e 98,5%, respectivamente. As PCR foram mais eficientes em identificar o tipo viral, a infecção pelo HTLV-2 e úteis para definir casos inconclusivos. CONCLUSÕES: Por serem sensÃveis, práticas e de custo muito inferior ao do WB, as técnicas de PCR em tempo real podem ser usadas como teste confirmatório do HTLV em bancos de sangue, em substituição ao WB