    Thoracoscopic Thoracic Duct Ligation for Persistent Cervical Chyle Leak: Utility of Immediate Pathologic Confirmation

    Get PDF
    ObjectiveChylous fistulas can occur after neck surgery. Both nonoperative measures and direct fistula ligation may lead to fistula resolution. However, a refractory fistula requires upstream thoracic duct ligation. This can be accomplished minimally invasively. Success depends on lymphatic flow interruption where the duct enters the thorax. We report on the utility of frozen section confirmation in achieving this goal.MethodsPersistent chylous fistulas occurred in 2 patients after left cervical operations. In the first patient, attempted direct fistula ligation and sclerosant application failed. Fasting, parenteral nutrition, and somatostatin-analog provided no benefit. For the second patient, nonoperative treatment was also ineffective. Prior radiation therapy and multiple cervical operations militated against attempted direct fistula ligation. Both patients underwent thoracoscopic thoracic duct interruption.ResultsIn both cases, a duct candidate was identified between the aorta and azygos vein. Frozen section analysis of tissue resected between endoclips verified it as thoracic duct. Fistula resolution ensued promptly in both instances.ConclusionsThis report lends further credence to the efficacy of minimally invasive thoracic duct ligation in treating postoperative cervical chylous fistulas. Frozen section confirmation of thoracic duct tissue is useful. It allows one facile with thoracoscopy, but less familiar with thoracic duct ligation, to confidently terminate the operation

    6.抗癌剤の腹腔動脈内one-shot注入で効果の見られた原発性肝癌の1症例(第593回千葉医学会例会・第1回千葉大学第3内科懇話会)

    Get PDF
    BACKGROUND:Apnea of Prematurity (AOP) is common, affecting the majority of infants born at <34 weeks gestational age. Apnea and periodic breathing are accompanied by intermittent hypoxia (IH). Animal and human studies demonstrate that IH exposure contributes to multiple pathologies, including retinopathy of prematurity (ROP), injury to sympathetic ganglia regulating cardiovascular action, impaired pancreatic islet cell and bone development, cerebellar injury, and neurodevelopmental disabilities. Current standard of care for AOP/IH includes prone positioning, positive pressure ventilation, and methylxanthine therapy; these interventions are inadequate, and not optimal for early development. OBJECTIVE:The objective is to support breathing in premature infants by using a simple, non-invasive vibratory device placed over limb proprioceptor fibers, an intervention using the principle that limb movements trigger reflexive facilitation of breathing. METHODS:Premature infants (23-34 wks gestational age), with clinical evidence of AOP/IH episodes were enrolled 1 week after birth. Caffeine treatment was not a reason for exclusion. Small vibration devices were placed on one hand and one foot and activated in 6 hour ON/OFF sequences for a total of 24 hours. Heart rate, respiratory rate, oxygen saturation (SpO2), and breathing pauses were continuously collected. RESULTS:Fewer respiratory pauses occurred during vibration periods, relative to baseline (p<0.005). Significantly fewer SpO2 declines occurred with vibration (p<0.05), relative to control periods. Significantly fewer bradycardic events occurred during vibration periods, relative to no vibration periods (p<0.05). CONCLUSIONS:In premature neonates, limb proprioceptive stimulation, simulating limb movement, reduces breathing pauses and IH episodes, and lowers the number of bradycardic events that accompany aberrant breathing episodes. This low-cost neuromodulatory procedure has the potential to provide a non-invasive intervention to reduce apnea, bradycardia and intermittent hypoxia in premature neonates. TRIAL REGISTRATION:ClinicalTrials.gov NCT02641249

    Improved costs and outcomes with conscious sedation vs general anesthesia in TAVR patients: Time to wake up?

    Get PDF
    BackgroundTranscatheter aortic valve replacement (TAVR) has become a commonplace procedure for the treatment of aortic stenosis in higher risk surgical patients. With the high cost and steadily increasing number of patients receiving TAVR, emphasis has been placed on optimizing outcomes as well as resource utilization. Recently, studies have demonstrated the feasibility of conscious sedation in lieu of general anesthesia for TAVR. This study aimed to investigate the clinical as well as cost outcomes associated with conscious sedation in comparison to general anesthesia in TAVR.MethodsRecords for all adult patients undergoing TAVR at our institution between August 2012 and June 2016 were included using our institutional Society of Thoracic Surgeons (STS) and American College of Cardiology (ACC) registries. Cost data was gathered using the BIOME database. Patients were stratified into two groups according to whether they received general anesthesia (GA) or conscious sedation (CS) during the procedure. No-replacement propensity score matching was done using the validated STS predicted risk of mortality (PROM) as a propensity score. Primary outcome measure with survival to discharge and several secondary outcome measures were also included in analysis. According to our institution's data reporting guidelines, all cost data is presented as a percentage of the general anesthesia control group cost.ResultsOf the 231 patients initially identified, 225 (157 GA, 68 CS) were included for analysis. After no-replacement propensity score matching, 196 patients (147 GA, 49 CS) remained. Overall mortality was 1.5% in the matched population with a trend towards lower mortality in the CS group. Conscious sedation was associated with significantly fewer ICU hours (30 vs 96 hours, p = &lt;0.001) and total hospital days (4.9 vs 10.4, p&lt;0.001). Additionally, there was a 28% decrease in direct cost (p&lt;0.001) as well as significant decreases in all individual all cost categories associated with the use of conscious sedation. There was no difference in composite major adverse events between groups. These trends remained on all subsequent subgroup analyses.ConclusionConscious sedation is emerging as a safe and viable option for anesthesia in patients undergoing transcatheter aortic valve replacement. The use of conscious sedation was not only associated with similar rates of adverse events, but also shortened ICU and overall hospital stays. Finally, there were significant decreases in all cost categories when compared to a propensity matched cohort receiving general anesthesia

    Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts

    Get PDF
    ObjectiveTo evaluate the role of iliac fixation in preventing migration of suprarenal and infrarenal aortic endografts.MethodsQuantitative image analysis was performed in 92 patients with infrarenal aortic aneurysms (76 men and 16 women) treated with suprarenal (n = 36) or infrarenal (n = 56) aortic endografts from 2000 to 2004. The longitudinal centerline distance from the superior mesenteric artery to the top of the stent graft was measured on preoperative, postimplantation, and 1-year three-dimensional computed tomographic scans, with movement more than 5 mm considered to be significant. Aortic diameters were measured perpendicular to the centerline axis. Proximal and distal fixation lengths were defined as the lengths of stent-graft apposition to the aortic neck and the common iliac arteries, respectively.ResultsThere were no significant differences in age, comorbidities, or preoperative aneurysm size (suprarenal, 6.0 cm; infrarenal, 5.7 cm) between the suprarenal and infrarenal groups. However, the suprarenal group had less favorable aortic necks with a shorter length (13 vs 25 mm; P < .0001), a larger diameter (27 vs 24 mm; P < .0001), and greater angulation (19° vs 11°; P = .007) compared with the infrarenal group. The proximal aortic fixation length was greater in the suprarenal than in the infrarenal group (22 vs 16 mm; P < .0001), with the top of the device closer to the superior mesenteric artery (8 vs 21 mm; P < .0001) as a result of the 15-mm uncovered suprarenal stent. There was no difference in iliac fixation length between the suprarenal and infrarenal groups (26 vs 25 mm; P = .8). Longitudinal centerline stent graft movement at 1 year was similar in the suprarenal and infrarenal groups (4.3 ± 4.4 mm vs 4.8 ± 4.3 mm; P = .6). Patients with longitudinal centerline movement of more than 5 mm at 1 year or clinical evidence of migration at any time during the follow-up period comprised the respective migrator groups. Suprarenal migrators had a shorter iliac fixation length (17 vs 29 mm; P = .006) and a similar aortic fixation length (23 vs 22 mm; P > .999) compared with suprarenal nonmigrators. Infrarenal migrators had a shorter iliac fixation length (18 vs 30 mm; P < .0001) and a similar aortic fixation length (14 vs 17 mm; P = .1) compared with infrarenal nonmigrators. Nonmigrators had closer device proximity to the hypogastric arteries in both the suprarenal (7 vs 17 mm; P = .009) and infrarenal (8 vs 24 mm; P < .0001) groups. No migration occurred in either group in patients with good iliac fixation. Multivariate logistic regression analysis revealed that iliac fixation, as evidenced by iliac fixation length (P = .004) and the device to hypogastric artery distance (P = .002), was a significant independent predictor of migration, whereas suprarenal or infrarenal treatment was not a significant predictor of migration. During a clinical follow-up period of 45 ± 22 months (range, 12-70 months), there have been no aneurysm ruptures, abdominal aortic aneurysm–related deaths, or surgical conversions in either group.ConclusionsDistal iliac fixation is important in preventing migration of both suprarenal and infrarenal aortic endografts that have longitudinal columnar support. Secure iliac fixation minimizes the risk of migration despite suboptimal proximal aortic neck anatomy. Extension of both iliac limbs to cover the entire common iliac artery to the iliac bifurcation seems to prevent endograft migration

    Aortoesophageal fistula involving the central aortic arch salvaged with emergent percutaneous TEVAR, great vessel coverage and in vivo graft fenestration

    Get PDF
    Immediate intervention is needed for aortoesophageal fistulas (AEF), a rare but highly lethal cause of massive gastrointestinal hemorrhage. Emergent thoracic endovascular aortic repair (TEVAR) is considered first-line treatment for massive bleeding from AEFs. We describe an unusual and challenging case of TEVAR coverage of an AEF involving the central aortic arch immediately followed by in vivo endograft fenestration to regain arch vessel perfusion. In vivo fenestration, currently a procedure for emergency or investigational purposes only, was shown to be life saving in our case. The main complications associated with the procedure included stroke and infection, requiring esophagectomy and cervical diversion as well as ongoing antibiotic treatment

    Three-Dimensional Impedance Tomographic Mapping of Metabolically Active Endolumen

    Get PDF
    Real-time detection of vulnerable atherosclerotic lesions, characterized by a high content of oxidized low-density lipoprotein (oxLDL)-laden macrophages or foam cells, remains an unmet clinical need. While fractional flow reserve (FFR)-guided revascularization in angiographically intermediate stenoses is utilized to assess hemodynamic significance, in vivo detection of oxLDL-rich plaques may provide a new paradigm for treating metabolically unstable lesions. Herein, we have demonstrated endoluminal mapping of lipid-laden lesions using 3-D electrical impedance spectroscopy-derived impedance tomography (EIT) in a pre-clinical swine model. We performed surgical banding of the right carotid arteries of Yucatan mini-pigs, followed by 16 weeks of high-fat diet, to promote the development of lipid-rich lesions. We implemented an intravascular sensor combining an FFR pressure transducer with a 6-point micro-electrode array for electrical impedance spectroscopy (EIS) measurements. 3-D EIT mapping was achieved using an EIS-based reconstruction algorithm. We demonstrated that EIT mapping corresponds to endoluminal histology for oxLDL-laden lesions. We further used computational models to theoretically predict and validate EIS measurements. Thus, our 3-D EIS-derived EIT provides in vivo detection of metabolically active plaques with the goal of guiding optimal intravascular intervention

    Neuromodulation in treatment of hypertension by acupuncture: A neurophysiological prospective

    No full text

    Prone Positioning for Acute Respiratory Distress Syndrome (ARDS)