Gas pixel detectors
Abstract With the Gas Pixel Detector (GPD), the class of micro-pattern gas detectors has reached a complete integration between the gas amplification structure and the read-out electronics. To obtain this goal, three generations of application-specific integrated circuit of increased complexity and improved functionality has been designed and fabricated in deep sub-micron CMOS technology. This implementation has allowed manufacturing a monolithic device, which realizes, at the same time, the pixelized charge-collecting electrode and the amplifying, shaping and charge measuring front-end electronics of a GPD. A big step forward in terms of size and performances has been obtained in the last version of the 0.18 ÎŒm CMOS analog chip, where over a large active area of 15Ă15 mm 2 a very high channel density (470 pixels/mm 2 ) has been reached. On the top metal layer of the chip, 105,600 hexagonal pixels at 50 ÎŒm pitch have been patterned. The chip has customable self-trigger capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way, by limiting the output signal to only those pixels belonging to the region of interest, it is possible to reduce significantly the read-out time and data volume. In-depth tests performed on a GPD built up by coupling this device to a fine pitch (50 ÎŒm) gas electron multiplier are reported. Matching of the gas amplification and read-out pitch has let to obtain optimal results. A possible application of this detector for X-ray polarimetry of astronomical sources is discussed
The silicon-strip tracker of the Gamma ray Large Area Space Telescope
Abstract The Gamma ray Large Area Space Telescope (GLAST) is an astro-particle mission that will study the mostly unexplored, high energy ( 20 MeV â 1 TeV ) spectrum of photons coming from active sources in the universe. Construction of the GLAST silicon tracker, by far the largest ever built for a space mission, is now well on the way, as it is scheduled for launch by NASA in autumn 2006. We report on the basic technology adopted for the silicon detectors, particularly in connection to their use in space, on the first results of sensors testing and on the status of tracker assembly
Precision measurements of the total and partial widths of the psi(2S) charmonium meson with a new complementary-scan technique in antiproton-proton annihilations
We present new precision measurements of the psi(2S) total and partial widths
from excitation curves obtained in antiproton-proton annihilations by Fermilab
experiment E835 at the Antiproton Accumulator in the year 2000. A new technique
of complementary scans was developed to study narrow resonances with
stochastically cooled antiproton beams. The technique relies on precise
revolution-frequency and orbit-length measurements, while making the analysis
of the excitation curve almost independent of machine lattice parameters. We
study the psi(2S) meson through the processes pbar p -> e+ e- and pbar p ->
J/psi + X -> e+ e- + X. We measure the width to be Gamma = 290 +- 25(sta) +-
4(sys) keV and the combination of partial widths Gamma_e+e- * Gamma_pbarp /
Gamma = 579 +- 38(sta) +- 36(sys) meV, which represent the most precise
measurements to date.Comment: 17 pages, 3 figures, 3 tables. Final manuscript accepted for
publication in Phys. Lett. B. Parts of the text slightly expanded or
rearranged; results are unchange
X-ray polarimetry with a micro pattern gas detector with pixel readout
In astronomy there are basically four kinds of observations to extract the information carried by electromagnetic radiation: photometry, imaging, spectroscopy, and polarimetry. By optimal exploitation of the first three techniques, X-ray astronomy has been able to unveil the violent world of compact high-energy sources. Here, we report on a new instrument that brings high efficiency also to X-ray polarimetry, the last unexplored field of X-ray astronomy. It will then be possible to resolve the internal structures of compact objects, which otherwise would remain inaccessible even to X-ray interferometry. The new instrument derives the polarization information from the track of the photoelectron imaged by a finely subdivided gas pixel detector. Its great improvement of sensitivity (at least two order of magnitude) will allow direct exploration of the most dramatic objects of the X-ray sky
Gas Pixel Detectors for X-ray Polarimetry applications
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector
(GPD), in which a complete integration between the gas amplification structure
and the read-out electronics has been reached. An Application-Specific
Integrated Circuit (ASIC) built in deep sub-micron technology has been
developed to realize a monolithic device that is, at the same time, the
pixelized charge collecting electrode and the amplifying, shaping and charge
measuring front-end electronics. The CMOS chip has the top metal layer
patterned in a matrix of 80 micron pitch hexagonal pixels, each of them
directly connected to the underneath electronics chain which has been realized
in the remaining five layers of the 0.35 micron VLSI technology. Results from
tests of a first prototype of such detector with 2k pixels and a full scale
version with 22k pixels are presented. The application of this device for
Astronomical X-Ray Polarimetry is discussed. The experimental detector response
to polarized and unpolarized X-ray radiation is shown. Results from a full
MonteCarlo simulation for two astronomical sources, the Crab Nebula and the
Hercules X1, are also reported.Comment: 16 pages, 20 figures, accepted for publication in Nuclear Instruments
and Methods in Physics Research Section
Measurement of the branching fraction
The branching fraction is measured in a data sample
corresponding to 0.41 of integrated luminosity collected with the LHCb
detector at the LHC. This channel is sensitive to the penguin contributions
affecting the sin2 measurement from The
time-integrated branching fraction is measured to be . This is the most precise measurement to
date
Model-independent search for CP violation in D0âKâK+ÏâÏ+ and D0âÏâÏ+Ï+Ïâ decays
A search for CP violation in the phase-space structures of D0 and View the MathML source decays to the final states KâK+ÏâÏ+ and ÏâÏ+Ï+Ïâ is presented. The search is carried out with a data set corresponding to an integrated luminosity of 1.0 fbâ1 collected in 2011 by the LHCb experiment in pp collisions at a centre-of-mass energy of 7 TeV. For the KâK+ÏâÏ+ final state, the four-body phase space is divided into 32 bins, each bin with approximately 1800 decays. The p-value under the hypothesis of no CP violation is 9.1%, and in no bin is a CP asymmetry greater than 6.5% observed. The phase space of the ÏâÏ+Ï+Ïâ final state is partitioned into 128 bins, each bin with approximately 2500 decays. The p-value under the hypothesis of no CP violation is 41%, and in no bin is a CP asymmetry greater than 5.5% observed. All results are consistent with the hypothesis of no CP violation at the current sensitivity
Absolute luminosity measurements with the LHCb detector at the LHC
Absolute luminosity measurements are of general interest for colliding-beam
experiments at storage rings. These measurements are necessary to determine the
absolute cross-sections of reaction processes and are valuable to quantify the
performance of the accelerator. Using data taken in 2010, LHCb has applied two
methods to determine the absolute scale of its luminosity measurements for
proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In
addition to the classic "van der Meer scan" method a novel technique has been
developed which makes use of direct imaging of the individual beams using
beam-gas and beam-beam interactions. This beam imaging method is made possible
by the high resolution of the LHCb vertex detector and the close proximity of
the detector to the beams, and allows beam parameters such as positions, angles
and widths to be determined. The results of the two methods have comparable
precision and are in good agreement. Combining the two methods, an overall
precision of 3.5% in the absolute luminosity determination is reached. The
techniques used to transport the absolute luminosity calibration to the full
2010 data-taking period are presented.Comment: 48 pages, 19 figures. Results unchanged, improved clarity of Table 6,
9 and 10 and corresponding explanation in the tex
Search for the lepton-flavor-violating decays Bs0âe±Όâ and B0âe±Όâ
A search for the lepton-flavor-violating decays Bs0âe±Όâ and B0âe±Όâ is performed with a data sample, corresponding to an integrated luminosity of 1.0ââfb-1 of pp collisions at âs=7ââTeV, collected by the LHCb experiment. The observed number of Bs0âe±Όâ and B0âe±Όâ candidates is consistent with background expectations. Upper limits on the branching fractions of both decays are determined to be B(Bs0âe±Όâ)101ââTeV/c2 and MLQ(B0âe±Όâ)>126ââTeV/c2 at 95% C.L., and are a factor of 2 higher than the previous bounds
- âŠ