671 research outputs found

    Low plasticity burnishing improves fretting fatigue resistance in bone-anchored implants for amputation prostheses

    Get PDF
    Fretting fatigue is a common problem for modular orthopedic implants which may lead to mechanical failure of the implant or inflammatory tissue responses due to excessive release of wear debris. Compressive residual stresses at the contacting surfaces may alleviate the problem. Here we investigate the potential of a surface enhancement method known as low plasticity burnishing (LPB) to increase the fretting fatigue resistance of bone-anchored implants for skeletal attachment of limb prostheses. Rotation bending fatigue tests performed on LPB treated and untreated test specimens demonstrate that the LPB treatment leads to statistically significantly increased resistance to fretting fatigue (LPB treated test specimens withstood on average 108,780 load cycles as compared with 37,845 load cycles for untreated test specimens, p = 0.004). LPB treated test specimens exhibited less wear at the modular interface as compared with untreated test specimens. This surface treatment may lead to reduced risk of fretting induced component failure and a reduced need for revision of implant system componentry

    The effect of cortical thickness and thread profile dimensions on stress and strain in bone-anchored implants for amputation prostheses

    Get PDF
    Skeletal attachment of limb prostheses ensures load transfer between the prosthetic leg and the skeleton. For individuals with lower limb amputation, these loads may be of substantial magnitude. To optimize the design of such systems, knowledge about the structural interplay between implant design features, dimensional changes, and material properties of the implant and the surrounding bone is needed. Here, we present the results from a parametric finite element investigation on a generic bone-anchored implant system of screw design, exposed to external loads corresponding to average and high ambulatory loading. Of the investigated parameters, cortical thickness had the largest effect on the stress and strain in the bone-anchored implant and in the cortical bone. 36%–44% reductions in maximum longitudinal stress in the bone-anchored implant was observed as a result of increased cortical thickness from 2 mm to 5 mm. A change in thread depth from 1.5 mm to 0.75 mm resulted in 20%–22% and 10%–18% reductions in maximum longitudinal stress in the bone-anchored implant at 2 mm and 5 mm cortical thickness respectively. The effect of changes in the thread root radius was less prominent, with 8% reduction in the maximum longitudinal stress in the bone-anchored implant being the largest observed effect, resulting from an increased thread root radius from 0.1 mm to 0.5 mm at a thread depth of 1.5 mm. Autologous transplantation of bone tissue distal to the fixture resulted in reductions in the longitudinal stress in the percutaneous abutment. The observed stress reduction of 10%–31% was dependent on the stiffness of the transplanted bone graft and the cortical thickness of surrounding bone. Results from this investigation may guide structural design optimization for bone-anchored implant systems for attachment of limb prostheses

    Patterned Stimulation of Peripheral Nerves Produces Natural Sensations With Regards to Location but Not Quality

    Get PDF
    Sensory feedback is crucial for dexterous manipulation and sense of ownership. Electrical stimulation of severed afferent fibers due to an amputation elicits referred sensations in the missing limb. However, these sensations are commonly reported with a concurrent “electric” or “tingling” character (paresthesia). In this paper, we examined the effect of modulating different pulse parameters on the quality of perceived sensations. Three subjects with above-elbow amputation were implanted with cuff electrodes and stimulated with a train of pulses modulated in either amplitude, width, or frequency (“patterned stimulation”). Pulses were shaped using a slower carrier wave or via quasi-random generation. Subjects were asked to evaluate the natural quality of the resulting sensations using a numeric rating scale. We found that the location of the percepts was distally referred and somatotopically congruent, but their quality remained largely perceived as artificial despite employing patterned modulation. Sensations perceived as arising from the missing limb are intuitive and natural with respect to their location and, therefore, useful for functional restoration. However, our results indicate that sensory transformation from paresthesia to natural qualia seems to require more than patterned stimulation

    Self-contained neuromusculoskeletal arm prostheses

    Get PDF
    We report the use of a bone-anchored, self-contained robotic arm with both sensory and motor components over 3 to 7 years in four patients after transhumeral amputation. The implant allowed for bidirectional communication between a prosthetic hand and electrodes implanted in the nerves and muscles of the upper arm and was anchored to the humerus through osseointegration, the process in which bone cells attach to an artificial surface without formation of fibrous tissue. Use of the device did not require formal training and depended on the intuitive intent of the user to activate movement and sensory feedback from the prosthesis. Daily use resulted in increasing sensory acuity and effectiveness in work and other activities of daily life

    Biomechanical Characterisation of Bone-anchored Implant Systems for Amputation Limb Prostheses: A Systematic Review

    Get PDF
    Bone-anchored limb prostheses allow for the direct transfer of external loads from the prosthesis to the skeleton, eliminating the need for a socket and the associated problems of poor fit, discomfort, and limited range of movement. A percutaneous implant system for direct skeletal attachment of an external limb must provide a long-term, mechanically stable interface to the bone, along with an infection barrier to the external environment. In addition, the mechanical integrity of the implant system and bone must be preserved despite constant stresses induced by the limb prosthesis. Three different percutaneous implant systems for direct skeletal attachment of external limb prostheses are currently clinically available and a few others are under investigation in human subjects. These systems employ different strategies and have undergone design changes with a view to fulfilling the aforementioned requirements. This review summarises such strategies and design changes, providing an overview of the biomechanical characteristics of current percutaneous implant systems for direct skeletal attachment of amputation limb prostheses

    Uncertainties in projecting climate-change impacts in marine ecosystems

    Get PDF
    Projections of the impacts of climate change on marine ecosystems are a key prerequisite for the planning of adaptation strategies, yet theyare inevitablyassociated withuncertainty.Identifying,quantifying,andcommunicatingthisuncertaintyis keytobothevaluatingtherisk associated with a projection and building confidence in its robustness. Wereview howuncertainties in such projections are handled in marine science. We employan approach developedin climatemodelling by breaking uncertainty down into(i) structural (model) uncertainty,(ii) initialization and internalvariabilityuncertainty,(iii)parametricuncertainty,and(iv)scenariouncertainty.Foreachuncertaintytype,wethenexaminethecurrent state-of-the-art in assessing and quantifying its relative importance. We consider whether the marine scientific community has addressed these types of uncertainty sufficiently and highlight the opportunities and challenges associated with doing a better job. We find that even within a relatively small field such as marine science, there are substantial differences between subdisciplines in the degree of attention given to each type of uncertainty. We find that initialization uncertainty is rarely treated explicitly and reducing this type of uncertainty may deliver gainsontheseasonal-to-decadaltime-scale.Weconcludethatallpartsofmarinesciencecouldbenefitfromagreaterexchangeofideas,particularly concerningsuchauniversalproblemsuchasthetreatmentofuncertainty.Finally,marinescienceshouldstrivetoreachthepointwherescenario uncertainty is the dominant uncertainty in our projections

    Neural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses

    Get PDF
    Conventional prosthetic arms suffer from poor controllability and lack of sensory feedback. Owing to the absence of tactile sensory information, prosthetic users must rely on incidental visual and auditory cues. In this study, we investigated the effect of providing tactile perception on motor coordination during routine grasping and grasping under uncertainty. Three transhumeral amputees were implanted with an osseointegrated percutaneous implant system for direct skeletal attachment and bidirectional communication with implanted neuromuscular electrodes. This neuromusculoskeletal prosthesis is a novel concept of artificial limb replacement that allows to extract control signals from electrodes implanted on viable muscle tissue, and to stimulate severed afferent nerve fibers to provide somatosensory feedback. Subjects received tactile feedback using three biologically inspired stimulation paradigms while performing a pick and lift test. The grasped object was instrumented to record grasping and lifting forces and its weight was either constant or unexpectedly changed in between trials. The results were also compared to the no-feedback control condition. Our findings confirm, in line with the neuroscientific literature, that somatosensory feedback is necessary for motor coordination during grasping. Our results also indicate that feedback is more relevant under uncertainty, and its effectiveness can be influenced by the selected neuromodulation paradigm and arguably also the prior experience of the prosthesis user

    Targeted prevention of common mental health disorders in university students: randomised controlled trial of a transdiagnostic trait-focused web-based intervention

    Get PDF
    Background: A large proportion of university students show symptoms of common mental disorders, such as depression, anxiety, substance use disorders and eating disorders. Novel interventions are required that target underlying factors of multiple disorders.<p></p> Aims: To evaluate the efficacy of a transdiagnostic trait-focused web-based intervention aimed at reducing symptoms of common mental disorders in university students.<p></p> Method: Students were recruited online (n = 1047, age: M = 21.8, SD = 4.2) and categorised into being at high or low risk for mental disorders based on their personality traits. Participants were allocated to a cognitive-behavioural trait-focused (n = 519) or a control intervention (n = 528) using computerised simple randomisation. Both interventions were fully automated and delivered online (trial registration: ISRCTN14342225). Participants were blinded and outcomes were self-assessed at baseline, at 6 weeks and at 12 weeks after registration. Primary outcomes were current depression and anxiety, assessed on the Patient Health Questionnaire (PHQ9) and Generalised Anxiety Disorder Scale (GAD7). Secondary outcome measures focused on alcohol use, disordered eating, and other outcomes.<p></p> Results: Students at high risk were successfully identified using personality indicators and reported poorer mental health. A total of 520 students completed the 6-week follow-up and 401 students completed the 12-week follow-up. Attrition was high across intervention groups, but comparable to other web-based interventions. Mixed effects analyses revealed that at 12-week follow up the trait-focused intervention reduced depression scores by 3.58 (p<.001, 95%CI [5.19, 1.98]) and anxiety scores by 2.87 (p = .018, 95%CI [1.31, 4.43]) in students at high risk. In high-risk students, between group effect sizes were 0.58 (depression) and 0.42 (anxiety). In addition, self-esteem was improved. No changes were observed regarding the use of alcohol or disordered eating.<p></p> Conclusions This study suggests that a transdiagnostic web-based intervention for university students targeting underlying personality risk factors may be a promising way of preventing common mental disorders with a low-intensity intervention

    The global seismographic network reveals atmospherically coupled normal modes excited by the 2022 Hunga Tonga Eruption

    Get PDF
    Summary The eruption of the submarine Hunga Tonga-Hunga Haʻapai (Hunga Tonga) volcano on January 15, 2022, was one of the largest volcanic explosions recorded by modern geophysical instrumentation. The eruption was notable for the broad range of atmospheric wave phenomena it generated and for their unusual coupling with the oceans and solid Earth. The event was recorded worldwide across the Global Seismographic Network (GSN) by seismometers, microbarographs, and infrasound sensors. The broadband instrumentation in the GSN allows us to make high fidelity observations of spheroidal solid Earth normal modes from this event at frequencies near 3.7 and 4.4 mHz. Similar normal modes reported following the 1991 Pinatubo (Volcanic Explosivity Index of 6) eruption and were predicted, by theory, to arise from the excitation of mesosphere-scale acoustic modes of the atmosphere coupling with the solid Earth. Here, we compare observations for the Hunga Tonga and Pinatubo eruptions and find that both strongly excited the Earth normal mode 0S29 (3.72 mHz) and that the modal amplitude was roughly 11 times larger for the 2022 Hunga Tonga eruption. Estimates of attenuation (Q) for 0S29 across the GSN from temporal modal decay give Q = 332 ± 101, which is higher than estimates of Q for this mode using earthquake data (Q = 186.9 ± 5; Dziewonski &amp; Anderson 1981). Two microbarographs located at regional distances (&amp;lt; 1000 km) to the volcano provide direct observations of the fundamental acoustic mode of the atmosphere. These pressure oscillations, first observed approximately 40 minutes after the onset of the eruption, are in phase with the seismic Rayleigh wave excitation and are recorded only by microbarographs in proximity (&amp;lt; 1500 km) to the eruption. We infer that excitation of fundamental atmospheric modes occurs within a limited area close to the site of the eruption, where they excite select solid Earth fundamental spheroidal modes of similar frequencies that are globally recorded and have a higher apparent Q due to the extended duration of atmospheric oscillations.</jats:p

    Model Structure of Human APOBEC3G

    Get PDF
    BACKGROUND: APOBEC3G (apolipoprotein B mRNA-editing enzyme, catalytic polypeptide-like 3G) has antiretroviral activity associated with the hypermutation of viral DNA through cytosine deamination. APOBEC3G has two cytosine deaminase (CDA) domains; the catalytically inactive amino-terminal domain of APOBEC3G (N-CDA) carries the Vif interaction domain. There is no 3-D structure of APOBEC3G solved by X-ray or nuclear magnetic resonance. METHODOLOGY/PRINCIPAL FINDINGS: We predicted the structure of human APOBEC3G based on the crystal structure of APOBEC2. To assess the model structure, we evaluated 48 mutants of APOBEC3G N-CDA that identify novel variants altering ΔVif HIV-1 infectivity and packaging of APOBEC3G. Results indicated that the key residue D128 is exposed at the surface of the model, with a negative local electrostatic potential. Mutation D128K changes the sign of that local potential. In addition, two novel functionally relevant residues that result in defective APOBEC3G encapsidation, R122 and W127, cluster at the surface. CONCLUSIONS/SIGNIFICANCE: The structure model identifies a cluster of residues important for packaging of APOBEC3G into virions, and may serve to guide functional analysis of APOBEC3G
    corecore