    Training and Transfer Effect of FluoroSim, an Augmented Reality Fluoroscopic Simulator for Dynamic Hip Screw Guidewire Insertion: A Single-Blinded Randomized Controlled Trial

    Get PDF
    BACKGROUND: FluoroSim, a novel fluoroscopic simulator, can be used to practice dynamic hip screw (DHS) guidewire insertion in a high-fidelity clinical scenario. Our aim was to demonstrate a training effect in undergraduate medical students who are not familiar with this operation and its simulation. METHODS: Forty-five undergraduate medical students were recruited and randomized to either training (n = 23) or control (n = 22) cohorts. The training cohort had more exposure to FluoroSim (5 attempts each week) over a 2-week period (with a 1-week washout period in between) compared with the control cohort (a single attempt 1 week apart) over a 2-week period. Five real-time objective performance metrics were recorded: (1) tip-apex distance (TAD) (mm), (2) predicted cut-out rate (%), (3) total procedural time (sec), (4) total number of radiographs (n), and (5) total number of guidewire retries (n). RESULTS: At baseline, there was no significant difference in the performance metrics, which confirmed the absence of a selection bias. The intragroup training effect demonstrated a significant improvement in all metrics for the training cohort only. A significant difference between groups was demonstrated as the training cohort significantly outperformed the control cohort in 3 metrics (procedural time [25%], number of radiographs [57%], and number of guidewire retries [100%]; p < 0.001). A learning curve showed an inversely proportional correlation between frequency of attempts and procedural time as well as the number of digital fluoroscopic radiographs that were made, indicating the development of psychomotor skills. There was also an improved baseline of the learning curve after the 1-week washout period, suggesting skill retention. CONCLUSIONS: Skill acquisition with the FluoroSim system was demonstrated with repeat exposure in a safe, radiation-free high-fidelity clinical simulation with actual operating room equipment. The task of DHS guidewire insertion requires cognitive and psychomotor skills that take a variable number of attempts to acquire, as demonstrated on the learning curve. Additional work is required to demonstrate that the skill tested by the FluoroSim is the same skill that is required for intraoperative DHS guidewire insertion. However, use of the FluoroSim provides improvement in skills with extra-clinical training opportunities for orthopaedic trainees. CLINICAL RELEVANCE: FluoroSim has demonstrated validity and training effect. It has the potential to be approved for possible use on patients in the operating room to help surgeons with the operation. Consequently, operating time, accuracy of TAD, and surgical outcomes may all be improved

    The role of the patellar tendon angle and patellar flexion angle in the interpretation of sagittal plane kinematics of the knee after knee arthroplasty: A modelling analysis

    Get PDF
    BACKGROUND: Many different measures have been used to describe knee kinematics. This study investigated the changes of two measures, the patellar tendon angle and the patellar flexion angle, in response to variations in the geometry of the knee due to surgical technique or implant design. METHODS: A mathematical model was developed to calculate the equilibrium position of the extensor mechanism for a particular tibiofemoral position. Calculating the position of the extensor mechanism allowed for the determination of the patellar tendon angle and patellar flexion angle relationships to the knee flexion angle. The model was used to investigate the effect of anterior-posterior position of the femur, change in joint line, patellar thickness (overstuffing, understuffing), and patellar tendon length; these parameters were varied to determine the effect on the patellar tendon angle/knee flexion angle and patellar flexion angle/knee flexion angle relationships. RESULTS: The patellar tendon angle was a good indicator of anterior-posterior femoral position and change in patellar thickness, and the patellar flexion angle a good indicator of change in joint line, and patellar tendon length. CONCLUSIONS: The patellar tendon angle/knee flexion angle relationship was found to be an effective means of identifying abnormal kinematics post-knee arthroplasty. However, the use of both the patellar tendon angle and patellar flexion angle together provided a more informative overview of the sagittal plane kinematics of the knee

    Conservation of Nonsense-Mediated mRNA Decay Complex Components Throughout Eukaryotic Evolution

    Get PDF
    Nonsense-mediated mRNA decay (NMD) is an essential eukaryotic process regulating transcript quality and abundance, and is involved in diverse processes including brain development and plant defenses. Although some of the NMD machinery is conserved between kingdoms, little is known about its evolution. Phosphorylation of the core NMD component UPF1 is critical for NMD and is regulated in mammals by the SURF complex (UPF1, SMG1 kinase, SMG8, SMG9 and eukaryotic release factors). However, since SMG1 is reportedly missing from the genomes of fungi and the plant Arabidopsis thaliana, it remains unclear how UPF1 is activated outside the metazoa. We used comparative genomics to determine the conservation of the NMD pathway across eukaryotic evolution. We show that SURF components are present in all major eukaryotic lineages, including fungi, suggesting that in addition to UPF1 and SMG1, SMG8 and SMG9 also existed in the last eukaryotic common ancestor, 1.8 billion years ago. However, despite the ancient origins of the SURF complex, we also found that SURF factors have been independently lost across the Eukarya, pointing to genetic buffering within the essential NMD pathway. We infer an ancient role for SURF in regulating UPF1, and the intriguing possibility of undiscovered NMD regulatory pathways

    How Accurate is the Use of Contralateral Implant Size as a Template in Bilateral Hemiarthroplasty?

    Get PDF
    Purpose Accurately predicting implant size for hemiarthroplasties offers an important contribution to theatre efficiency and patients’ intraoperative care. However, pre-operative sizing using templating of implants in hip fracture patients requiring a hemiarthroplasty is often difficult due to non-standard radiographs, absence of a calibration marker, poor marker placement, variable patient position, and in many institutions a lack of templating facilities. In patients who have previously undergone a hemiarthroplasty on the contralateral side, surgeons can use the contralateral implant size for pre-operative planning purposes. However, the accuracy of doing this has not previously been reported. The aim of this study was to investigate the reliability of using an in situ contralateral implant as a predictor of implant size on the contralateral side. Methods A retrospective review of our local neck of femur fracture (NOF) database was undertaken to identify patients who had bilateral hip hemiarthroplasty. Operative records were reviewed to establish the size of prostheses used at operation. Correlation, agreement, and reliability analysis were performed using the least squares, Bland–Altman plot, and intra-class correlation coefficient (ICC) methods, respectively. Results Operative records were identified for 45 patients who had bilateral hemiarthroplasties. There was a difference in implant size used in 58% of cases. Of these 77% required a larger implant on the right. Implant sizes were within 1 mm of the contralateral side in 78% and within 2 mm in 91% of patients. However, in 9% of patients, there was a discrepancy greater than 2 mm with some cases having up to 6 mm discrepancy. Correlation coefficient was 0.83 and the ICC 0.90. Conclusions The findings in this study indicated that using the size of a contralateral implant can be used as a reliable indicator of head size in cases of bilateral hemiarthroplasty. However, the surgeon should remain cautious as there is a one in ten chance of there being a 3 mm or more difference in implant size

    Posterior Bearing Overhang Following Medial and Lateral Mobile Bearing Unicompartmental Knee Replacements

    Get PDF
    This study explores the extent of bearing overhang following mobile bearing Oxford unicompartmental knee replacement (OUKR) (Oxford Phase 3, Zimmer Biomet). The Oxford components are designed to be fully congruent, however knee movements involve femoral rollback, which may result in bearing overhang at the posterior margin of the tibial implant, with potential implications for; pain, wear, and dislocation. Movement is known to be greater, and therefore posterior overhang more likely to occur, with; lateral compared to medial implants, anterior cruciate ligament deficiency, and at extremes of movement. 24 medial, and 20 domed lateral, OUKRs underwent sagittal plane knee fluoroscopy during step‐up and forward lunge exercises. The bearing position was inferred from the relative position of the femoral and tibial components. Based on the individual component sizes and geometry the extent the posterior part of the bearing which overhung the posterior part of the tibial component was calculated. There was no significant posterior overhang in knees with medial implants. Knees with lateral domed implants exhibited overhang at flexion angles beyond 60°, the magnitude of which increased with increasing flexion angle, reaching a maximum of 50% of the bearing length at 140° (range 0‐140°). This demonstrates a clear difference between the kinematics, and prevalence and extent of posterior bearing overhang between medial and lateral OUKRs

    Efficacy of Liver Transplantation in Patients with Primary Biliary Cirrhosis

    Get PDF
    No controlled trials have been performed to assess the efficacy of liver transplantation. Because of the marked improvement in survival after liver transplantation since 1981, random assignment of patients to a control group not undergoing transplantation is considered clinically inappropriate. To assess the efficacy of liver transplantation in patients with primary biliary cirrhosis, we compared survival in 161 patients with this diagnosis who had undergone a liver transplantation with survival in patients with the same diagnosis who had been treated conservatively. The comparison was performed with use of a recently developed statistical technique, the Mayo model. All patients had undergone liver transplantation between March 1980 and June 1987 and were followed for a median of 25 months. Three months after liver transplantation, the Kaplan–Meier survival probabilities in the recipients were substantially higher than the Mayo-model “simulated-control” survival probabilities (P<0.001). At two years, the Kaplan–Meier survival probability was 0.74, whereas the mean Mayo-model survival probability was 0.31. The patients who were at low risk according to the Mayo model had the best probability of survival after liver transplantation; however, patients at all risk levels who had undergone liver transplantation had higher probabilities of survival than those who had not. We conclude that liver transplantation is an efficacious treatment in patients with advanced primary biliary cirrhosis. (N Engl J Med 1989; 320:1709–13.), LIVER transplantation has been accepted clinically as a lifesaving treatment in various end-stage liver diseases, including primary biliary cirrhosis.1,2 However, no controlled trials have been performed to evaluate the efficacy of this procedure. Indeed, because there has been a marked improvement since 1981 in survival after transplantation, random assignment of patients with advanced liver disease to a nontransplantation control group is considered to be clinically inappropriate. At the Mayo Clinic, a Cox regression model for predicting the probability of survival in patients with conservatively treated primary biliary cirrhosis has been developed.3 To provide control data for assessing the efficacy of