6 research outputs found
Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker
Abstract
During the operation of the CMS experiment at the
High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker
will be exposed to radiation levels that could potentially
deteriorate their performance. Previous studies had determined that
planar float zone silicon with n-doped strips on a p-doped substrate
was preferred over p-doped strips on an n-doped substrate. The last
step in evaluating the optimal design for the mass production of
about 200 m2 of silicon sensors was to compare sensors of
baseline thickness (about 300 μm) to thinned sensors (about
240 μm), which promised several benefits at high radiation
levels because of the higher electric fields at the same bias
voltage. This study provides a direct comparison of these two
thicknesses in terms of sensor characteristics as well as charge
collection and hit efficiency for fluences up to
1.5 × 1015 neq/cm2. The measurement results
demonstrate that sensors with about 300 μm thickness will
ensure excellent tracking performance even at the highest considered
fluence levels expected for the Phase-2 Outer
Tracker.</jats:p
Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC
Abstract
The CMS Inner Tracker, made of silicon pixel modules, will
be entirely replaced prior to the start of the High Luminosity LHC
period. One of the crucial components of the new Inner Tracker
system is the readout chip, being developed by the RD53
Collaboration, and in particular its analogue front-end, which
receives the signal from the sensor and digitizes it. Three
different analogue front-ends (Synchronous, Linear, and
Differential) were designed and implemented in the RD53A
demonstrator chip. A dedicated evaluation program was carried out to
select the most suitable design to build a radiation tolerant pixel
detector able to sustain high particle rates with high efficiency
and a small fraction of spurious pixel hits. The test results showed
that all three analogue front-ends presented strong points, but also
limitations. The Differential front-end demonstrated very low noise,
but the threshold tuning became problematic after
irradiation. Moreover, a saturation in the preamplifier feedback
loop affected the return of the signal to baseline and thus
increased the dead time. The Synchronous front-end showed very good
timing performance, but also higher noise. For the Linear front-end
all of the parameters were within specification, although this
design had the largest time walk. This limitation was addressed and
mitigated in an improved design. The analysis of the advantages and
disadvantages of the three front-ends in the context of the CMS
Inner Tracker operation requirements led to the selection of the
improved design Linear front-end for integration in the final CMS
readout chip.</jats:p
Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade
International audienceThe Short Strip ASIC (SSA) is one of the four front-endchips designed for the upgrade of the CMS Outer Tracker for the HighLuminosity LHC. Together with the Macro-Pixel ASIC (MPA) it willinstrument modules containing a strip and a macro-pixel sensorstacked on top of each other. The SSA provides both full readout ofthe strip hit information when triggered, and, together with theMPA, correlated clusters called stubs from the two sensors for useby the CMS Level-1 (L1) trigger system. Results from the firstprototype module consisting of a sensor and two SSA chips arepresented. The prototype module has been characterized at theFermilab Test Beam Facility using a 120 GeV proton beam
Evaluation of HPK - planar pixel sensors for the CMS Phase-2 upgrade
International audienceTo cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), sched-uled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determinedby the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 1034 cm−2 s−1 in the ultimate perfor-mance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluencecorresponding to a non-ionizing energy loss of up to Φeq = 3.5 × 1016 cm−2. This paper focuses on planar pixel sensor design andqualification up to a fluence of Φeq = 1.4 × 1016 cm−2.For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150 mm(6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm2 and 50 × 50 μm2 manufactured by Hamamatsu.Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was anextensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly withROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakagecurrent and efficiency. The single point resolution for 50 × 50 μm2 pixels is measured as 4.0 μm for non-irradiated samples, and6.3 μm after irradiation to Φeq = 7.2 × 1015 cm−2
Evaluation of HPK - planar pixel sensors for the CMS Phase-2 upgrade
To cope with the challenging environment of the planned high luminosity upgrade
of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10~years with an instantaneous peak luminosity of up to
~cms in the ultimate performance scenario.
Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to ~cm. This paper focuses on planar pixel sensor design and qualification up to a fluence of ~cm.
For the development of appropriate planar pixel
sensors an R\&D program was initiated, which includes - sensors on
150 mm (6'')
wafers with an active thickness of 150~m with pixel sizes of
~m and
~m manufactured by Hamamatsu Photonics K.K.\ (HPK). Single chip
modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out.
This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips.
It demonstrates that
multiple designs fulfill the requirements
in terms of breakdown voltage, leakage current and efficiency. The single
point resolution for ~m pixels
is measured as 4.0~m for non-irradiated samples,
and 6.3~m after irradiation to ~cm.To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), sched-
uled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined
by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 1034 cm−2 s−1 in the ultimate perfor-
mance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence
corresponding to a non-ionizing energy loss of up to Φeq = 3.5 × 1016 cm−2. This paper focuses on planar pixel sensor design and
qualification up to a fluence of Φeq = 1.4 × 1016 cm−2.
For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150 mm
(6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm2 and 50 × 50 μm2 manufactured by Hamamatsu.
Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an
extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with
ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage
current and efficiency. The single point resolution for 50 × 50 μm2 pixels is measured as 4.0 μm for non-irradiated samples, and
6.3 μm after irradiation to Φeq = 7.2 × 1015 cm−2.To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 1034cm−2s−1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to Φeq= 3.5 × 1016cm−2. This paper focuses on planar pixel sensor design and qualification up to a fluence of Φeq = 1.4 × 1016cm−2. For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150mm (6”) wafers with an active thickness of 150µm with pixel sizes of 100×25 µm2 and 50×50 µm2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50×50 µm2 pixels is measured as 4.0µm for non-irradiated samples, and 6.3µm after irradiation to Φeq = 7.2 × 1015cm−2
Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade
Abstract
The Short Strip ASIC (SSA) is one of the four front-end
chips designed for the upgrade of the CMS Outer Tracker for the High
Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will
instrument modules containing a strip and a macro-pixel sensor
stacked on top of each other. The SSA provides both full readout of
the strip hit information when triggered, and, together with the
MPA, correlated clusters called stubs from the two sensors for use
by the CMS Level-1 (L1) trigger system. Results from the first
prototype module consisting of a sensor and two SSA chips are
presented. The prototype module has been characterized at the
Fermilab Test Beam Facility using a 120 GeV proton beam.</jats:p