411 research outputs found

    Simulations of Time-Resolved X-Ray Diffraction in Laue Geometry

    Full text link
    A method of computer simulation of Time-Resolved X-ray Diffraction (TRXD) in asymmetric Laue (transmission) geometry with an arbitrary propagating strain perpendicular to the crystal surface is presented. We present two case studies for possible strain generation by short-pulse laser irradiation: (i) a thermoelastic-like analytic model; (ii) a numerical model including effects of electron-hole diffusion, Auger recombination, deformation potential and thermal diffusion. A comparison with recent experimental results is also presented.Comment: 9 pages, 11 figure

    Prediction for new magnetoelectric fluorides

    Get PDF
    We use symmetry considerations in order to predict new magnetoelectric fluorides. In addition to these magnetoelectric properties, we discuss among these fluorides the ones susceptible to present multiferroic properties. We emphasize that several materials present ferromagnetic properties. This ferromagnetism should enhance the interplay between magnetic and dielectric properties in these materials.Comment: 12 pages, 4 figures, To appear in Journal of Physics: Condensed Matte

    Direct determination of free metal concentration by implementing stripping chronopotentiometry as second stage of AGNES

    Get PDF
    The electroanalytical technique Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) has been extended by applying stripping chronopotentiometry (SCP) as the re-oxidation stage in the determination of the free concentration of Zn2+, Cd2+ and Pb2+. This new approach, called AGNES-SCP, has been implemented with screen-printed electrodes (SPE) and the standard Hanging Mercury Drop Electrode (HMDE). Clear advantages of this variant have been shown: (i) the easy resolution of the peaks of different metals present in mixtures and (ii) the sparing of blanks. A rigorous computation of the faradaic charge along the SCP stage takes into account the contribution of other oxidants, which can be efficiently measured at the end of the deposition stage of AGNES. The free Cd concentration determined in an oxalate solution at pH 6 with an HMDE as the working electrode agreed well with values obtained with a Cd Ion Selective Electrode. The free metal concentration measured using an SPE for the system Cd and nitrilotriacetic acid (NTA) at pH = 4.8 also conformed well with Visual MINTEQ results

    Takagi-Taupin Description of X-ray Dynamical Diffraction from Diffractive Optics with Large Numerical Aperture

    Full text link
    We present a formalism of x-ray dynamical diffraction from volume diffractive optics with large numerical aperture and high aspect ratio, in an analogy to the Takagi-Taupin equations for strained single crystals. We derive a set of basic equations for dynamical diffraction from volume diffractive optics, which enable us to study the focusing property of these optics with various grating profiles. We study volume diffractive optics that satisfy the Bragg condition to various degrees, namely flat, tilted and wedged geometries, and derive the curved geometries required for ultimate focusing. We show that the curved geometries satisfy the Bragg condition everywhere and phase requirement for point focusing, and effectively focus hard x-rays to a scale close to the wavelength.Comment: 18 pages, 12 figure

    Non-purged voltammetry explored with AGNES

    Get PDF
    The reduction of oxygen increases pH in the surroundings of an electrode. A theoretical model estimates the steady-state pH profile from the surface of the electrode up to the bulk solution. A very simple formula predicts that, in non-deareated solutions, for bulk pH-values between 4.0 and 10.0, the corresponding surface pH could be as high as 10.3, regardless of the thickness of the diffusion layer and composition of the sample (except if it has a buffering capacity). For bulk pH lower than 3.0 or higher than 10, pH increases are negligible. Less steep pH-profiles are obtained with buffers (such as MOPS 0.01 M or MES 0.01 M). The change in surface pH modifies the local speciation and hinders the standard interpretation of voltammetric responses. The electroanalytical technique Absence of Gradients and Nernstian Equilibrium Stripping (AGNES), implemented with Screen Printed Electrodes (SPE), provides experimental insights into this phenomenon. AGNES probes the free metal concentration at the electrode surface, from which the surface pH can be estimated for systems of known composition. These estimations agree with the theoretical model for the assayed systems. Additionally, the quantification of the bulk free Zn2+ and Cd2+ concentrations with specific modifications of AGNES for non-purged synthetic solutions is discussed. In general, more accurate determinations of the bulk free metal concentrations in non-purged solutions are expected: i) when the calibration is performed in a medium where the pH increase induces similar changes in the surface free metal concentration and in the sample solution and ii) when the system is more buffered.This work was financially supported by the Spanish Ministry of Education and Science (Projects CTQ2009-07831, CTM2009-14612 and CTM2012-39183), from the “Comissionat per a Universitats i Recerca del Departament d'Innovació, Universitats i Empresa de la Generalitat de Catalunya”

    Magnetoelectric coupling in the cubic ferrimagnet Cu2OSeO3

    Get PDF
    We have investigated the magnetoelectric coupling in the lone pair containing piezoelectric ferrimagnet Cu2OSeO3. Significant magnetocapacitance develops in the magnetically ordered state (TC = 60 K). We find critical behavior near TC and a divergence near the metamagnetic transition at 500 Oe. High-resolution X-ray and neutron powder diffraction measurements show that Cu2OSeO3 is metrically cubic down to 10 K but that the ferrimagnetic ordering reduces the symmetry to rhombohedral R3. The metric cubic lattice dimensions exclude a magnetoelectric coupling mechanism involving spontaneous lattice strain, and this is unique among magnetoelectric and multiferroic materials.Comment: accepted for publication in PR

    Free Zn2+ determination in natural freshwater of the Pyrenees: towards on-site measurements with AGNES

    Get PDF
    An on-site methodology has been developed for the direct determination of free Zn2+ with AGNES (Absence of Gradients and Nernstian Equilibrium Stripping) in freshwaters. This implementation includes: i) the use of screen printed electrodes, which provide good limits of detection and easy transportation and deployment; ii) no need for sample purging; iii) a calibration in a synthetic river solution that reproduces well the speciation changes of the natural samples and allows the oxygen interferences to be minimised; iv) the addition of a background electrolyte up to 0.01 mol L-1 in both the calibration and freshwater samples; v) chemical stripping chronopotentiometry as the quantification stage of AGNES. This procedure minimizes the effects of working at low ionic strength and in the presence of dissolved oxygen. In the laboratory, the methodology was checked with different natural samples taken from rivers Garonne, Gave de Cauterets and Gave de Pau in the Pyrenees. Results appeared in good agreement with theoretical estimations computed from Visual Minteq. On-site measurements were performed for the first time with AGNES in the Gave de Cauterets in Soulom (France) and the results were corroborated with purged measurements performed in the laboratory.English language editing by Holly Pearson is acknowledged. The authors acknowledge support for this research from the Communaut e d’Agglom eration de Pau Pyr en ees (CDAPP), from the Spanish Ministerio de Ciencia e Innovacio´n (project numbers CTM2012–39183 and CTM2013– 48967), from the European Community EFA15/08 (PyrMet) and from the Comissionat d’Universitats i Recerca de la Generalitat de Catalunya (project number 2014SGR1132)

    The Drift Chambers Of The Nomad Experiment

    Get PDF
    We present a detailed description of the drift chambers used as an active target and a tracking device in the NOMAD experiment at CERN. The main characteristics of these chambers are a large area, a self supporting structure made of light composite materials and a low cost. A spatial resolution of 150 microns has been achieved with a single hit efficiency of 97%.Comment: 42 pages, 26 figure

    The probe beam linac in CTF3

    Get PDF
    JACoW web site http://accelconf.web.cern.ch/AccelConf/e06/The test facility CTF3, presently under construction at CERN within an international collaboration, is aimed at demonstrating the key feasibility issues of the multi-TeV linear collider CLIC. The objective of the probe beam linac is to "mimic" the main beam of CLIC in order to measure precisely the performances of the 30 GHz CLIC accelerating structures. In order to meet the required parameters of this 200 MeV probe beam, in terms of emittance, energy spread and bunch-length, the most advanced techniques have been considered: laser triggered photo-injector, velocity bunching, beam-loading compensation, RF pulse compression ... The final layout is described, and the selection criteria and the beam dynamics results are reviewed
    corecore