357 research outputs found

    Sequential effects in two-choice reaction time tasks: decomposition and synthesis of mechanisms

    Get PDF
    Performance on serial tasks is influenced by first- and higher-order sequential effects, respectively due to the immediately previous and earlier trials. As response-to-stimulus interval (RSI) increases, the pattern of reaction times transits from a benefit-only mode, traditionally ascribed to automatic facilitation (AF), to a cost-benefit mode, due to strategic expectancy (SE). To illuminate the sources of such effects, we develop a connectionist network of two mutually-inhibiting neural decision units subject to feedback from previous trials. A study of separate biasing mechanisms shows that residual decision unit activity can lead only to first-order AF, but higher-order AF can result from strategic priming mediated by conflict-monitoring, which we instantiate in two distinct versions. A further mechanism mediates expectation-related biases that grow during RSI toward saturation levels determined by weighted repetition (or alternation) sequence lengths. Equipped with these mechanisms, the network, consistent with known neurophysiology, accounts for several sets of behavioral data over a wide range of RSIs. The results also suggest that practice speeds up all the mechanisms rather than adjusting their relative strengths

    Prolonged treatment of COVID-19 pneumonia with high-flow nasal oxygen: A story of oxygen and resilience

    Get PDF
    The COVID-19 pandemic has placed significant strain on the oxygen delivery infrastructure of health facilities in resource-constrained health systems. In this case report, we describe a patient with severe COVID-19 pneumonia who was managed with high-flow nasal oxygen for 40 days, with an eventual successful outcome. We discuss the oxygen delivery infrastructure needed to offer this intervention, as well as the psychosocial impact on those undergoing treatment

    Electrical cross talk of a frequency division multiplexing readout for a transition edge sensor bolometer array

    Get PDF
    We have characterized and mapped the electrical cross talk (ECT) of a frequency division multiplexing (FDM) system with a transition edge sensor (TES) bolometer array, which is intended for space applications. By adding a small modulation at 120 Hz to the AC bias voltage of one bolometer and measuring the cross talk response in the current noise spectra of the others simultaneously, we have for the first time mapped the ECT level of 61 pixels with a nominal frequency spacing of 32 kHz in a 61 × 61 matrix and a carrier frequency ranging from 1 MHz to 4 MHz. We find that about 94% of the pixels show an ECT level of less than 0.4%. Only the adjacent pixels reach this level, and the ECT for the rest of the pixels is less than 0.1%. We also observe higher ECT levels, up to 10%, between some of the pixels, which have bundled long, parallel coplanar wires connecting TES bolometers to inductor-capacitor filters. In this case, the high mutual inductances dominate. To mitigate this source of ECT, the coplanar wires should be replaced by microstrip wires in the array. Our study suggests that an FDM system can have a relatively low ECT level, e.g., around 0.4% if the frequency spacing is 30 kHz. Our results successfully demonstrate a low electrical cross talk for a space FDM technology

    Frequency division multiplexing readout of 60 low-noise transition-edge sensor bolometers

    Get PDF
    We demonstrate multiplexing readout of 60 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing readout chain with bias frequencies ranging from 1 to 3.5 MHz and with a typical frequency spacing of 32 kHz. The readout chain starts with a two-stage SQUID amplifier and has a noise level of 9.5 pA/ √{ Hz } . We compare current-voltage curves and noise spectra of TESs measured in a single-pixel mode and in a multiplexing mode. We also map the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where there are 43 pixels that do not show more than 10% difference in NEP and 5% in saturation power when measured in single pixel and multiplex modes. We have read out a TES with an NEP of 0.45 aW/ √{ Hz } in the multiplexing-mode, which demonstrates the capability of reading out ultra-low noise TES bolometer arrays for space applications

    B-Pol: Detecting Primordial Gravitational Waves Generated During Inflation

    Full text link
    B-Pol is a medium-class space mission aimed at detecting the primordial gravitational waves generated during inflation through high accuracy measurements of the Cosmic Microwave Background (CMB) polarization. We discuss the scientific background, feasibility of the experiment, and implementation developed in response to the ESA Cosmic Vision 2015-2025 Call for Proposals.Comment: Experimental Astronomy - The original publication is available at http://www.springerlink.co

    Beyond the required LISA free-fall performance: new LISA pathfinder results down to 20  ΌHz

    Get PDF
    In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20  ΌHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05)  fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10  fm s^{-2}/sqrt[Hz] at 20  ΌHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency

    A strategy to characterize the LISA-Pathfinder cold gas thruster system

    Get PDF
    The cold gas micro-propulsion system that will be used during the LISA-Pathfinder mission will be one of the most important component used to ensure the "free-fall" of the enclosed test masses. In this paper we present a possible strategy to characterize the effective direction and amplitude gain of each of the 6 thrusters of this system

    Free-flight experiments in LISA Pathfinder

    Get PDF
    The LISA Pathfinder mission will demonstrate the technology of drag-free test masses for use as inertial references in future space-based gravitational wave detectors. To accomplish this, the Pathfinder spacecraft will perform drag-free flight about a test mass while measuring the acceleration of this primary test mass relative to a second reference test mass. Because the reference test mass is contained within the same spacecraft, it is necessary to apply forces on it to maintain its position and attitude relative to the spacecraft. These forces are a potential source of acceleration noise in the LISA Pathfinder system that are not present in the full LISA configuration. While LISA Pathfinder has been designed to meet it's primary mission requirements in the presence of this noise, recent estimates suggest that the on-orbit performance may be limited by this `suspension noise'. The drift-mode or free-flight experiments provide an opportunity to mitigate this noise source and further characterize the underlying disturbances that are of interest to the designers of LISA-like instruments. This article provides a high-level overview of these experiments and the methods under development to analyze the resulting data.Comment: 13 pages, 5 figures. Accepted to Journal Of Physics, Conference Series. Presented at 10th International LISA Symposium, May 2014, Gainesville, FL, US
    • 

    corecore