39 research outputs found
Prompt and Long-term Prophylactic Effect of Closed Loop Stimulation against Paroxysmal Atrial Fibrillation in a Patient with Sick Sinus Syndrome
A 72-year-old woman with sick sinus syndrome (SSS), who had frequent paroxysmal atrial fibrillations (PAfs) and normal cardiac function, was admitted to our hospital due to syncope. PAfs frequently occurred during the first week after DDD pacemaker implantation (PMI), with closed loop stimulation (CLS) rate-adaptive mode off, but were completely suppressed during the second week, with CLS on, and had been well-controlled over three years thereafter. However, PAfs occasionally occurred under intense sympathetic activity during 6 months after PMI as well, and were effectively terminated by disopyramide which had anticholinergic effect. Thus, the development and maintenance of PAf were thought to be associated with destabilized cardiac autonomic activities, that is, sympathetic and parasympathetic dominance, respectively. Additionally, heart rate variability analyses after implementation of CLS revealed the restoration of sympathetic and parasympathetic components. Accordingly, CLS mode was considered to play a critical role in preventing PAf by reflecting autonomic activity in heart rhythm in this SSS patient
R&D Progress of HTS Magnet Project for Ultrahigh-field MRI
Proceedings of the 28th International Symposium on Superconductivity (ISS 2015) November 16-18, 2015, Tokyo, JapanAn R&D project on high-temperature superconducting (HTS) magnets using rare-earth Ba2Cu3O7 (REBCO) wires was started in 2013. The project objective is to investigate the feasibility of adapting REBCO magnets to ultrahigh field (UHF) magnetic resonance imaging (MRI) systems. REBCO wires are promising components for UHF-MRI magnets because of their superior superconducting and mechanical properties, which make them smaller and lighter than conventional ones. Moreover, REBCO magnets can be cooled by the conduction-cooling method, making liquid helium unnecessary. In the past two years, some test coils and model magnets have been fabricated and tested. This year is the final year of the project. The goals of the project are: (1) to generate a 9.4 T magnetic field with a small test coil, (2) to generate a homogeneous magnetic field in a 200 mm diameter spherical volume with a 1.5 T model magnet, and (3) to perform imaging with the 1.5 T model magnet. In this paper, the progress of this R&D is described. The knowledge gained through these R&D results will be reflected in the design of 9.4 T MRI magnets for brain and whole body imaging
An association between systolic blood pressure and stroke among patients with impaired consciousness in out-of-hospital emergency settings
Background: Stroke is difficult to diagnose when consciousness is disturbed. However few reports have discussed the clinical predictors of stroke in out-of-hospital emergency settings. This study aims to evaluate the association between initial systolic blood pressure (SBP) value measured by emergency medical service (EMS) and diagnosis of stroke among impaired consciousness patients. Methods: We included all patients aged 18 years or older who were treated and transported by EMS, and had impaired consciousness (Japan Coma Scale ≧ 1) in Osaka City (2.7 million), Japan from January 1, 1998 through December 31, 2007. Data were prospectively collected by EMS personnel using a study-specific case report form. Multiple logistic regressions assessed the relationship between initial SBP and stroke and its subtypes adjusted for possible confounding factors. Results: During these 10 years, a total of 1,840,784 emergency patients who were treated and transported by EMS were documented during the study period in Osaka City. Out of 128,678 with impaired consciousness, 106,706 who had prehospital SBP measurements in the field were eligible for our analyses. The proportion of patients with severe impaired consciousness significantly increased from 14.5% in the =200 mmHg SBP group (P for trend =200 mmHg group versus the SBP 101-120 mmHg group was 5.26 (95% CI 4.93 to 5.60). The AOR of the SBP > =200 mmHg group versus the SBP 101-120 mmHg group was 9.76 in subarachnoid hemorrhage (SAH), 16.16 in intracranial hemorrhage (ICH), and 1.52 in ischemic stroke (IS), and the AOR of SAH and ICH was greater than that of IS. Conclusions: Elevated SBP among emergency patients with impaired consciousness in the field was associated with increased diagnosis of stroke
Effectiveness of prehospital Magill forceps use for out-of-hospital cardiac arrest due to foreign body airway obstruction in Osaka City
Background: Although foreign body airway obstruction (FBAO) accounts for many preventable unintentional accidents, little is known about the epidemiology of FBAO patients and the effect of forceps use on those patients. This study aimed to assess characteristics of FBAO patients transported to hospitals by emergency medical service (EMS) personnel, and to verify the relationship between prehospital Magill forceps use and outcomes among out-of-hospital cardiac arrests (OHCA) patients with FBAO. Methods: We retrospectively reviewed ambulance records of all patients who suffered FBAO, and were treated by EMS in Osaka City from 2000 through 2007, and assessed the characteristics of those patients. We also performed a multivariate logistic-regression analysis to assess factors associated with neurologically favorable survival among bystander-witnessed OHCA patients with FBAO in larynx or pharynx. Results: A total of 2,354 patients suffered from FBAO during the study period. There was a bimodal distribution by age among infants and old adults. Among them, 466 (19.8%) had an OHCA when EMS arrived at the scene, and 344 were witnessed by bystanders. In the multivariate analysis, Magill forceps use for OHCA with FBAO in larynx or pharynx was an independent predictor of neurologically favorable survival (16.4% [24/146] in the Magill forceps use group versus 4.3% [4/94] in the non-use group; adjusted odds ratio, 3.96 [95% confidence interval, 1.21-13.00], p = 0.023).Conclusions: From this large registry in Osaka, we revealed that prehospital Magill forceps use was associated with the improved outcome of bystander-witnessed OHCA patients with FBAO
Shorter recovery can be achieved from using walking boot after operative treatment of an ankle fracture
Background/Objective: Ankle fractures, even if treated surgically, usually take a long time to heal. For all patients with ankle fracture, immobilisation is a critical part of treatment. Short-leg walking boots (WBs) have been reported to be an effective alternative to plaster casts (PCs) that could shorten this postoperative recuperative period. The aim of this study was to compare the functional recovery of a conventional PC with that of a WB after surgery for ankle fractures.
Methods: Forty-seven patients (mean age, 53.9±12 years) who had undergone surgical operation for an unstable ankle fracture from January 2008 to October 2014 were reviewed retrospectively. Either a PC or a WB was prescribed postoperatively, with 25 patients and 22 patients, respectively. The time that it took the patient to stand unipedal on the affected side after allowing full-weight bear and to walk without crutches were used for assessment of functional recovery. The prevalence of postoperative loss of reduction and nonunion was also reviewed.
Results: Both the time of being able to stand unipedal on the injured side and to walk without crutches were significantly shorter in patients using WBs (WB, 2.6 weeks; PC, 4.5 weeks, p=0.01; WB, 1.4 weeks; PC, 3.1 weeks, p=0.03). There were no patients with loss of reduction or nonunion.
Conclusion: Patients who used WBs showed a significantly faster recovery. WBs have an adjustable heel lift that allows users to change the ankle position slightly plantarflexed that helps walking in a postoperative swollen ankle. WBs are easy to slip on, and it is easy to adjust the ankle position in conformity with swelling so that the least painful position could be maintained during walking. WBs have good fixity to allow immediate weight-bearing postoperatively, and there were no cases with loss of reduction postoperatively. The Rocker bottom design minimises the sagittal plane motion in the specific joint of the foot, which also facilitates the course of recuperation. An ankle fracture fixed appropriately endures loading when a WB is used. The WB treatment results in faster functional recovery, allowing the patients to return to normal activity at a faster rate