15 research outputs found

    Random field sampling for a simplified model of melt-blowing considering turbulent velocity fluctuations

    Full text link
    In melt-blowing very thin liquid fiber jets are spun due to high-velocity air streams. In literature there is a clear, unsolved discrepancy between the measured and computed jet attenuation. In this paper we will verify numerically that the turbulent velocity fluctuations causing a random aerodynamic drag on the fiber jets -- that has been neglected so far -- are the crucial effect to close this gap. For this purpose, we model the velocity fluctuations as vector Gaussian random fields on top of a k-epsilon turbulence description and develop an efficient sampling procedure. Taking advantage of the special covariance structure the effort of the sampling is linear in the discretization and makes the realization possible

    Variation in the dispersions of powder liquid ratios in hand-mix glass ionomers

    Get PDF
    BACKGROUND: The Powder/Liquid Ratio (PLR) influence, and the literature regarding the handling and physical properties of Glass Ionomer restorative materials (GIC) were investigated. OBJECTIVE: The objective of the study was to compare the PLR variability and magnitude in hand-mix GICs, as dispensed for clinical use. From the recorded individual powder and liquid weights, additional comparisons could be made by pairing the various “extreme” outer observations in relation to the manufacturer’s PLR. STUDY DESIGN: The materials assessed were Ketac Universal Hand-mix (KUH), Riva Self Cure Hand-mix (RSCH) and Fuji IX GP Hand-mix (FIXH). Twenty scoops of powder were paired with twenty drops of liquid, as would be the case in the clinical scenario. Statistical analysis was completed with the Kruskal Wallis H test, Intraclass Correlation (ICC) and straight line regressions with One-way ANOVA and the post-hoc Tukey HSD Test (p<0.05 was considered significant). RESULTS: The powder and liquid observations indicate a lack of consistency in both the powder and liquid dispersions. The volume remained “one drop” but the weights were much lower than the manufacturer’s recommended drop weight for some observations, due to air in the liquid drop. The Kruskal-Wallis H test indicated significant differences (p=0.0001) between the three materials for the paired PLRs. The One-way ANOVA and post-hoc Tukey HSD Test were used to compare the recommended PLR to the results and the significant differences (p<0.01). CONCLUSION: The recommended manufacturers’ powder and liquid weights were KUH 0.150/0.05g; RSC 0.165/0.035; FIXH 0.18/0.05, respectively. KUH, FIXH and RSCH liquid had powder and liquid dispersions above the manufacturer’s recommendations. FIXH had the most paired PLR observations within the ±10% range followed by KUH. Extreme powder and liquid combinations could occur in the clinical scenario and these combinations were considered

    Positively versus Negatively Frequency-Dependent Selection

    No full text
    Abstract. Frequency-dependent selection (FDS) refers to situations where individual fitnesses are dependent (to some degree) on where the individual’s alleles lie in the proximate allele frequency distribution. If the dependence is negative – that is, if alleles become increasingly detrimental to fitness as they become increasingly common at a given locus – then genetic diversity may be maintained. If the dependence is positive, then alleles may converge at given loci. A hypothetical evolutionary model of FDS is here presented, in which the individuals themselves determined – by means of a gene – whether their fitnesses were positively or negatively frequency-dependent. The population ratio of the two types of individual was monitored in runs with different parameters, and explanations of what happened are offered. Key words: Frequency-dependent selection, multiple alleles, meta gene
    corecore