301 research outputs found

    A Continuum Robot and Control Interface for Surgical Assist in Fetoscopic Interventions

    Get PDF
    Twin-twin transfusion syndrome requires interventional treatment using a fetoscopically introduced laser to sever the shared blood supply between the fetuses. This is a delicate procedure relying on small instrumentation with limited articulation to guide the laser tip and a narrow field of view to visualize all relevant vascular connections. In this letter, we report on a mechatronic design for a comanipulated instrument that combines concentric tube actuation to a larger manipulator constrained by a remote centre of motion. A stereoscopic camera is mounted at the distal tip and used for imaging. Our mechanism provides enhanced dexterity and stability of the imaging device. We demonstrate that the imaging system can be used for computing geometry and enhancing the view at the operating site. Results using electromagnetic sensors for verification and comparison to visual odometry from the distal sensor show that our system is promising and can be developed further for multiple clinical needs in fetoscopic procedures

    Electrically tunable organic-inorganic hybrid polaritons with monolayer WS2.

    Get PDF
    Exciton-polaritons are quasiparticles consisting of a linear superposition of photonic and excitonic states, offering potential for nonlinear optical devices. The excitonic component of the polariton provides a finite Coulomb scattering cross section, such that the different types of exciton found in organic materials (Frenkel) and inorganic materials (Wannier-Mott) produce polaritons with different interparticle interaction strength. A hybrid polariton state with distinct excitons provides a potential technological route towards in situ control of nonlinear behaviour. Here we demonstrate a device in which hybrid polaritons are displayed at ambient temperatures, the excitonic component of which is part Frenkel and part Wannier-Mott, and in which the dominant exciton type can be switched with an applied voltage. The device consists of an open microcavity containing both organic dye and a monolayer of the transition metal dichalcogenide WS2. Our findings offer a perspective for electrically controlled nonlinear polariton devices at room temperature

    Survival of HIV-positive patients starting antiretroviral therapy between 1996 and 2013: a collaborative analysis of cohort studies

    Get PDF
    BACKGROUND: Health care for people living with HIV has improved substantially in the past two decades. Robust estimates of how these improvements have affected prognosis and life expectancy are of utmost importance to patients, clinicians, and health-care planners. We examined changes in 3 year survival and life expectancy of patients starting combination antiretroviral therapy (ART) between 1996 and 2013. METHODS: We analysed data from 18 European and North American HIV-1 cohorts. Patients (aged ≄16 years) were eligible for this analysis if they had started ART with three or more drugs between 1996 and 2010 and had at least 3 years of potential follow-up. We estimated adjusted (for age, sex, AIDS, risk group, CD4 cell count, and HIV-1 RNA at start of ART) all-cause and cause-specific mortality hazard ratios (HRs) for the first year after ART initiation and the second and third years after ART initiation in four calendar periods (1996–99, 2000–03 [comparator], 2004–07, 2008–10). We estimated life expectancy by calendar period of initiation of ART. FINDINGS: 88 504 patients were included in our analyses, of whom 2106 died during the first year of ART and 2302 died during the second or third year of ART. Patients starting ART in 2008–10 had lower all-cause mortality in the first year after ART initiation than did patients starting ART in 2000–03 (adjusted HR 0·71, 95% CI 0·61–0·83). All-cause mortality in the second and third years after initiation of ART was also lower in patients who started ART in 2008–10 than in those who started in 2000–03 (0·57, 0·49–0·67); this decrease was not fully explained by viral load and CD4 cell count at 1 year. Rates of non-AIDS deaths were lower in patients who started ART in 2008–10 (vs 2000–03) in the first year (0·48, 0·34–0·67) and second and third years (0·29, 0·21–0·40) after initiation of ART. Between 1996 and 2010, life expectancy in 20-year-old patients starting ART increased by about 9 years in women and 10 years in men. INTERPRETATION: Even in the late ART era, survival during the first 3 years of ART continues to improve, which probably reflects transition to less toxic antiretroviral drugs, improved adherence, prophylactic measures, and management of comorbidity. Prognostic models and life expectancy estimates should be updated to account for these improvements

    Validation of the Spanish Version of the ICECAP-O for Nursing Home Residents with Dementia

    Get PDF
    Background Measurement of health-related quality of life (HRQoL) is important for a chronic disease, such as dementia, which impairs the quality of life of affected patients in addition to their length of life. This is important in the context of economic evaluations when interventions do not (only) affect HRQoL and these other factors also affect overall quality of life. Objective To validate the Spanish translation of the ICECAP-O's capability to measure Health-related quality of life in elderly with dementia who live in nursing homes. Method Cross-sectional study. For 217 residents living in 8 Spanish nursing homes, questionnaires were completed by nursing professionals serving as proxy respondents. We analyzed the internal consistency and other psychometric properties. We investigated the convergent validity of the ICECAP-O with other HRQoL instruments, the EQ-5D extended with a cognitive dimension (EQ-5D+C), the Alzheimer's Disease Related Quality of Life (ADRQL) measures, and the Barthel Index measure of activities of daily living (ADL). Results The ICECAP-O presents satisfactory internal consistency (alpha 0.820). The factorial analysis indicated a structure of five principal dimensions that explain 66.57% of the total variance. Convergent validity between the ICECAP-O, EQ-5D+C, ADRQL, and Barthel Index scores was moderate to good (with correlations of 0.62, 0.61, and 0.68, respectively), but differed between dimensions of the instruments. Discriminant validity was confirmed by finding differences in ICECAP-O scores between subgroups based on ADL scores (0.70 low, 0.59 medium, and 0.39 high level care), dementia severity (0.72 mild, 0.63 medium, and 0.50 severe), and ages (0.59 below 75 years and 0.84 above 75 years). Conclusions This study presented the first use of a Spanish version of the ICECAP-O. The results indicate that the ICECAP-O appears to be a reliable Health-related quality of life measurement instrument showing good convergent and discriminant validity for people with dementia

    Final results on neutrino oscillation parameters from the OPERA experiment in the CNGS beam

    Get PDF
    International audienceThe OPERA experiment has conclusively observed the appearance of tau neutrinos in the muon neutrino CNGS beam. Exploiting the OPERA detector capabilities, it was possible to isolate high purity samples of Îœe, ΜΌ and Μτ charged current weak neutrino interactions, as well as neutral current weak interactions. In this paper, the full dataset is used for the first time to test the three-flavor neutrino oscillation model and to derive constraints on the existence of a light sterile neutrino within the framework of the 3+1 neutrino model. For the first time, tau and electron neutrino appearance channels are jointly used to test the sterile neutrino hypothesis. A significant fraction of the sterile neutrino parameter space allowed by LSND and MiniBooNE experiments is excluded at 90% C.L. In particular, the best-fit values obtained by MiniBooNE combining neutrino and antineutrino data are excluded at 3.3σ significance

    Measurement of the cosmic ray muon flux seasonal variation with the OPERA detector

    Get PDF
    The OPERA experiment discovered muon neutrino into tau neutrino oscillations in appearance mode, detecting tau leptons by means of nuclear emulsion films. The apparatus was also endowed with electronic detectors with tracking capability, such as scintillator strips and resistive plate chambers. Because of its location, in the underground Gran Sasso laboratory, under 3800 m.w.e., the OPERA detector has also been used as an observatory for TeV muons produced by cosmic rays in the atmosphere. In this paper the measurement of the single muon flux modulation and of its correlation with the seasonal variation of the atmospheric temperature are reported

    Study of charged hadron multiplicities in charged-current neutrino-lead interactions in the OPERA detector (vol 78, 62, 2018)

    Get PDF
    Erratum to: Eur. Phys. J. C (2018) 78:6
    • 

    corecore