22 research outputs found

    Development, Validation and Applications of a Novel Multiplex Assay RM-Yplex Amplifying 13 Rapidly Mutating Y Chromosome Short Tandem Repeat Regions

    Get PDF
    A polymerase chain reaction (PCR) multiplex assay capable of amplifying 13 rapidly mutating Y chromosome short tandem repeats (RM Y-STRs) simultaneously was developed and optimised. This multiplex assay which was termed RM-Yplex is the first to include all 13 RM Y-STRs including DYF387S1, DYF399S1, DYF403S1a/b, DYF404S1, DYS449, DYS518, DYS526a/b DYS547, DYS570, DYS576, DYS612, DYS626 and DYS627. A developmental validation was performed following the Scientific Working Group for DNA Analysis Methods (SWGDAM) revised guidelines. Robustness and limitations of the assay were demonstrated through a range of studies including reproducibility, sensitivity, specificity, stability and mixture studies. Appropriate controls were used during the studies that included a number of male and female commercial controls including, 2800M, 9948 and Taqman male controls and 9947A female control. An allelic ladder was developed for the assignment of the alleles. This was done by choosing samples with different alleles, amplifying them and then adjusting the volumes of amplified products in a mixture. The developed mixtures were used to balance the composite ladder. Multiple alleles of the various loci included in the ladder were sequenced. Reference haplotypes were developed for the 5 male samples included in the Y chromosome Standard Reference Material 2395 (SRM2395) using RM-Yplex. The International Society of Forensic Genetics (ISFG) recommendations were followed for adopting allele nomenclature. As part of developmental validation, the assay was included in an external proficiency trial which was concluded successfully. An internal validation of RM-Yplex was carried out at the Department of Forensic Sciences and Criminology Laboratory, Dubai where apart from other studies; application of the assay was demonstrated using non-probative forensic casework samples. The value of RM-Yplex was demonstrated for differentiating close male relatives in a case where a previously used Y-STR multiplex assay had shown identical haplotypes for those individuals. 1160 male individual samples were analysed in this study including UAE, other Arabian Peninsula populations as well as two South Asian populations residing in United Arab Emirates. RM-Yplex haplotypes have extremely high power of discrimination. The haplotype diversity for RM-Yplex haplotype is much more than the existing commercial Y-STR assays. Population studies have been carried out for the Arab, Indian and Pakistani populations. AMOVA was conducted for determining the apportionment of diversity and pairwise FST’s were estimated between populations. These have shown a marked homogeneity within the UAE Arab sub-populations. MDS plots of pairwise FST’s indicated that populations were not grouped significantly in accordance with the geographical locations. A network analysis showed the extent of distribution of haplotypes of various populations and their relationships. A highly sensitive and reliable RM-Yplex multiplex assay has been thus developed, which is expected to help genetic populations studies and forensic casework

    Mobile phones of paediatric hospital staff are never cleaned and commonly used in toilets with implications for healthcare nosocomial diseases

    Get PDF
    An ever-increasing number of medical staff use mobile phones as a work aid, yet this may pose nosocomial diseases. To assess and report via a survey the handling practices and the use of phones by paediatric wards healthcare workers. 165 paediatric healthcare workers and staff filled in a questionnaire consisting of 14 questions (including categorical, ordinal and numerical data). Analysis of categorical data used non-parametric techniques such as the Chi-squared test. Although 98% of respondents (165 in total) report that their phones may be contaminated, 56% have never cleaned their devices. Of the respondents that clean their devices, 10% (17/165) had done so with alcohol swabs or disinfectant within that day or week; and an additional 12% respondents (20/165) within that month. Of concern, 52% (86/165) of the respondents use their phones in the bathroom, emphasising the unhygienic environments in which mobile phones/smartphones are constantly used. Disinfecting phones is a practice that only a minority of healthcare workers undertake appropriately. Mobile phones, present in billions globally, are therefore Trojan Horses if contaminated with microbes and potentially contributing to the spread and propagation of micro-organisms as per the rapid spread of SARS-CoV-2 virus in the world

    A novel multiplex assay for simultaneously analysing 13 rapidly mutating Y-STRs

    Get PDF
    A multiplex polymerase chain reaction (PCR) assay (RM-Yplex) was developed which is capable of simultaneously amplifying 13 recently introduced rapidly mutating Y-STR markers (RM Y-STRs). This multiplex assay is expected to aid human identity testing in forensic and other applications to improve differentiating unrelated males and allow separating related males. The 13 RM Y-STR markers included in the multiplex are: DYF387S1, DYF399S1, DYF403S1ab, DYF404S1, DYS449, DYS518, DYS526ab, DYS547, DYS570, DYS576, DYS612, DYS626 and DYS627. This study reflects the proof of concept to analyse all currently known RM Y-STRs simultaneously and describes the optimization of the multiplex assay. The RM-Yplex assay generated complete RM Y-STR profiles down to 62.5 pg of male template DNA, and from male–female DNA mixtures at all ratios tested. We herewith introduce and make available for widespread use in forensic and anthropological studies, an effective and sensitive single multiplex assay for simultaneous genotyping of 13 RM Y-STRs

    Plastic induced urinary tract disease and dysfunction: a scoping review

    Get PDF
    Introduction: In 2019 the World Health Organisation published a report which concluded microplastics in drinking water did not present a threat to human health. Since this time a plethora of research has emerged demonstrating the presence of plastic in various organ systems and their deleterious pathophysiological effects.Methods: A scoping review was undertaken in line with recommendations from the Johanna Briggs Institute. Five databases (PubMed, SCOPUS, CINAHL, Web of Science and EMBASE) were systematically searched in addition to a further grey literature search.Results: Eighteen articles were identified, six of which investigated and characterised the presence of microplastics and nanoplastics (MNPs) in the human urinary tract. Microplastics were found to be present in kidney, urine and bladder cancer samples. Twelve articles investigated the effect of MNPs on human cell lines associated with the human urinary tract. These articles suggest MNPs have a cytotoxic effect, increase inflammation, decrease cell viability and alter mitogen-activated protein kinases (MAPK) signalling pathways.Conclusion: Given the reported presence MNPs in human tissues and organs, these plastics may have potential health implications in bladder disease and dysfunction. As a result, institutions such as the World Health Organisation need to urgently re-evaluate their position on the threat of microplastics to public health.Impact statement: This scoping review highlights the rapidly emerging threat of microplastic contamination within the human urinary tract, challenging the World Health Organisation’s assertion that microplastics pose no risk to public health. The documented cytotoxic effects of microplastics, alongside their ability to induce inflammation, reduce cell viability and disrupt signalling pathways, raise significant public health concerns relating to bladder cancer, chronic kidney disease, chronic urinary tract infections and incontinence. As a result, this study emphasises the pressing need for further research and policy development to address the challenges surrounding microplastic contamination.<br/

    Extended Reality Head-Mounted Displays Are Likely to Pose a Significant Risk in Medical Settings While Current Classification Remains as Non-Critical

    Get PDF
    Extended reality (XR) devices, including virtual and augmented reality head-mounted displays (HMDs), are increasingly utilised within healthcare to provide clinical interventions and education. Currently, XR devices are utilised to assist in reducing pain and improving psychological outcomes for immunocompromised patients in intensive care units, palliative care environments and surgical theatres. However, there is a paucity of research on the risks of infection from such devices in healthcare settings. Identify existing literature providing insights into the infection control risk XR HMDs pose within healthcare facilities and the efficacy of current infection control and cleaning procedures. Three databases (PubMed, Embase and CINAHL) in addition to Google Scholar were systematically searched. A total of seven studies were identified for this review. Microorganisms, including pathogenic bacteria (e.g., Staphylococcus aureus and Pseudomonas aeruginosa), were found to be present on XR HMDs. Published cleaning and infection control protocols designed to disinfect XR HMDs and protect users were heterogeneous in nature. Current cleaning protocols displayed varying levels of efficacy with microbial load affected by multiple factors, including time in use, number of users and XR HMD design features. In healthcare settings, fitting XR HMDs harbouring microorganisms near biological and mucosal entry points presents an infection control risk. An urgent revision of the Spaulding classification is required to ensure flexibility that allows for these devices to be reclassified from ‘Non-critical’ to ‘Semi-Critical’ depending on the healthcare setting and patient population (surgery, immunocompromised, burns, etc.). This review identified evidence supporting the presence of microorganisms on XR HMDs. Due to the potential for HMDs to contact mucosal entry points, devices must be re-considered within the Spaulding classification as ‘Semi-critical’. The existence of microbial contaminated XR HMDs in high-risk medical settings such as operating wards, intensive care units, emergency departments, labour and delivery wards and clinical areas with immunosuppressed patients requires urgent attention. Public health authorities have a duty of care to develop revised guidelines or new recommendations to ensure efficient sanitation of such devices

    Ultraviolet-c-based mobile phone sanitisation for global public health and infection control

    Get PDF
    Introduction. Mobile phones act as fomites that pose a global public health risk of disseminating microorganisms, including highly pathogenic strains possessing antimicrobial resistances. The use of ultraviolet-C (UV-C) to sanitise mobile phones presents an alternative means to complement basic hand hygiene to prevent the cross-contamination and dissemination of microorganisms between hands and mobile phones. Aim. This study aimed to evaluate the germicidal efficacy of the Glissner CleanPhone UV-C phone sanitiser (Glissner) device. Methods. Two experimental trials were performed for the evaluation of the CleanPhone (Glissner). The first was a controlled trial, where the germicidal efficacy of the CleanPhone was evaluated against six different microorganism species that were inoculated onto mobile phones. The second was a field trial evaluating the germicidal efficacy of the CleanPhone on 100 volunteer mobile phones. Efficacy was determined based on colony counts of microorganisms on Columbia sheep blood agar before and after UV-C treatment. Results. In the controlled trial, reduction in growth was observed for all microorganisms after UV-C treatment with ST131 Escherichia coli showing the highest growth reduction at 4 log10 CFU/mL followed by C. albicans and ATCC E. coli at 3 log10 CFU/mL. An overall reduction in microorganism growth after UV-C treatment was also observed for the field trial, with an average growth reduction of 84.4% and 93.6% in colony counts at 24 h and 48 h post-incubation, respectively. Conclusion. The findings demonstrated the capability of the CleanPhone (Glissner) to rapidly sanitise mobile phones, thereby providing a means to reduce the potential dissemination of microorganisms, including highly pathogenic strains with antimicrobial resistance

    Mobile phones as fomites for pathogenic microbes: A cross-sectional survey of perceptions and sanitization habits of health care workers in Dubai, United Arab Emirates

    Get PDF
    Backgrounds In 2022, smartphone use continues to expand with the number of smartphone subscriptions surpassing 6 billion and forecasted to grow to 7.5 billion by 2026. The necessity of these ‘high touch’ devices as essential tools in professional healthcare settings carries great risks of cross-contamination between mobile phones and hands. Current research emphasises mobile phones as fomites enhancing the risk of nosocomial disease dissemination as phone sanitisation is often overlooked. To assess and report via a large-scale E-survey the handling practices and the use of phones by healthcare workers. Methods A total of 377 healthcare workers (HCWs) participated in this study to fill in an E-survey online consisting of 14 questions (including categorical, ordinal, and numerical data). Analysis of categorical data used non-parametric techniques such as Pearson's chi-squared test. Results During an 8-h shift, 92.8% (n/N = 350/377) use their phone at work with 84.6% (n/N = 319/377) considering mobile phones as an essential tool for their job. Almost all HCWs who participated in this survey believe their mobile phones could potentially harbour microorganisms (97.1%; n/N = 366/377). Fifty-seven respondents (15.1%) indicated that they use their phones while wearing gloves and 10.3% (n/N = 39/377) have never cleaned their phones. The majority of respondents (89.3%; n/N = 337/377) agreed that contaminated mobile phones could contribute to dissemination of SARS-CoV-2. Conclusion Mobile phone use is now almost universal and indispensable in healthcare. Medical staff believe mobile phones can act as fomites with a potential risk for dissemination of microbes including SARS-COV-2. There is an urgent call for the incorporation of mobile phone sanitisation in infection prevention protocol. Studies on the use of ultraviolet-C based phone sanitation devices in health care settings are needed

    Microbial laden mobile phones from international conference attendees pose potential risks to public health and biosecurity

    Get PDF
    Introduction Mobile phones, contaminated with pathogenic microorganisms, have the potential to act as “trojan horses”. The microbial signatures present on their surfaces most probably vary across different geographical regions. As a result, mobile phones belonging to international conference attendees may serve as a model for global microbial dissemination, posing potential risks to public health and biosecurity. Aim This study aimed to profile the microbes present on mobile phones belonging to delegates attending an international scientific conference through use of metagenomic shotgun DNA sequencing. Methods Twenty mobile phones, representing ten different geographical zones from around the world, were swabbed and pooled together into ten geographical-specific samples for high definition next-generation DNA sequencing. WONCA council members were invited to participate and provided verbal consent. Following DNA extraction, next generation sequencing, to a depth of approximately 10Gbp per sample, was undertaken on a v1.5 Illumina NovaSeq6000 system. Bioinformatic analysis was performed via the CosmosID platform. Results A total of 2204 microbial hits were accumulated across 20 mobile phones inclusive of 882 bacteria, 1229 viruses, 88 fungi and 5 protozoa. Of particular concern was the identification of 65 distinct antibiotic resistance genes and 86 virulence genes. Plant, animal and human pathogens, including ESKAPE and HACEK bacteria were found on mobile phones. Discussion/conclusion Mobile phones of international attendees are contaminated with many & varied microorganisms. Further research is required to characterize the risks these devices pose for biosecurity and public health. Development of new policies which appropriately address and prevent such risks maybe warranted

    Metagenomic sequencing and reverse transcriptase PCR reveal That mobile phones and environmental surfaces are reservoirs of multidrug-fesistant superbugs and SARS-CoV-2

    Get PDF
    Background: Mobile phones of healthcare workers (HCWs) can act as fomites in the dissemination of microbes. This study was carried out to investigate microbial contamination of mobile phones of HCWs and environmental samples from the hospital unit using a combination of phenotypic and molecular methods. Methods: This point prevalence survey was carried out at the Emergency unit of a tertiary care facility. The emergency unit has two zones, a general zone for non-COVID-19 patients and a dedicated COVID-19 zone for confirmed or suspected COVID-19 patients. Swabs were obtained from the mobile phones of HCWs in both zones for bacterial culture and shotgun metagenomic analysis. Metagenomic sequencing of pooled environmental swabs was conducted. RT-PCR for SARS-CoV-2 detection was carried out. Results: Bacteria contamination on culture was detected from 33 (94.2%) mobile phones with a preponderance of Staphylococcus epidermidis (n/N = 18/35), Staphylococcus hominis (n/N = 13/35), and Staphylococcus haemolyticus (n/N = 7/35). Two methicillin-sensitive and three methicillin-resistant Staphylococcus aureus, and one pan-drug-resistant carbapenemase producer Acinetobacter baumannii were detected. Shotgun metagenomic analysis showed high signature of Pseudomonas aeruginosa in mobile phone and environmental samples with preponderance of P. aeruginosa bacteriophages. Malassezia and Aspergillus spp. were the predominant fungi detected. Fourteen mobile phones and one environmental sample harbored protists. P. aeruginosa antimicrobial resistance genes mostly encoding for efflux pump systems were detected. The P. aeruginosa virulent factor genes detected were related to motility, adherence, aggregation, and biofilms. One mobile phone from the COVID-19 zone (n/N = 1/5; 20%) had positive SARS-CoV-2 detection while all other phone and environmental samples were negative. Conclusion: The findings demonstrate that mobile phones of HCWs are fomites for potentially pathogenic and highly drug-resistant microbes. The presence of these microbes on the mobile phones and hospital environmental surfaces is a concern as it poses a risk of pathogen transfer to patients and dissemination into the community

    Microsatellites’ mutation modeling through the analysis of the Y-chromosomal transmission: Results of a GHEP-ISFG collaborative study

    Get PDF
    The Spanish and Portuguese Speaking Working Group of the International Society for Forensic Genetics (GHEP-ISFG) organized a collaborative study on mutations of Y-chromosomal short tandem repeats (Y-STRs). New data from 2225 father-son duos and data from 44 previously published reports, corresponding to 25,729 duos, were collected and analyzed. Marker-specific mutation rates were estimated for 33 Y-STRs. Although highly dependent on the analyzed marker, mutations compatible with the gain or loss of a single repeat were 23.2 times more likely than those involving a greater number of repeats. Longer alleles (relatively to the modal one) showed to be nearly twice more mutable than the shorter ones. Within the subset of longer alleles, the loss of repeats showed to be nearly twice more likely than the gain. Conversely, shorter alleles showed a symmetrical trend, with repeat gains being twofold more frequent than reductions. A positive correlation between the paternal age and the mutation rate was observed, strengthening previous findings. The results of a machine learning approach, via logistic regression analyses, allowed the establishment of algebraic formulas for estimating the probability of mutation depending on paternal age and allele length for DYS389I, DYS393 and DYS627. Algebraic formulas could also be established considering only the allele length as predictor for DYS19, DYS389I, DYS389II-I, DYS390, DYS391, DYS393, DYS437, DYS439, DYS449, DYS456, DYS458, DYS460, DYS481, DYS518, DYS533, DYS576, DYS626 and DYS627 loci. For the remaining Y-STRs, a lack of statistical significance was observed, probably as a consequence of the small effective size of the subsets available, a common difficulty in the modeling of rare events as is the case of mutations. The amount of data used in the different analyses varied widely, depending on how the data were reported in the publications analyzed. This shows a regrettable waste of produced data, due to inadequate communication of the results, supporting an urgent need of publication guidelines for mutation studies.info:eu-repo/semantics/publishedVersio
    corecore