6 research outputs found

    Static and dynamic baropodometry to evaluate patients treated by total knee replacement with a mobile meniscus.

    No full text
    none5It was the purpose of this study to use static and dynamic baropodometry pre- and postsurgery in patients submitted to knee replacement with a mobile bearing. Baropodometric analysis was accompanied by clinical and subjective evaluation. Data obtained from the baropodometer revealed considerable oscillations occurring between pre- and postsurgery. Static examination showed a significant increase in the percentage of loading on the side treated that was not observed in the dynamic evaluation. An analysis of the Knee Society score showed a considerable increase in values between pre- and postsurgery similar to how the interpretation of correlations presurgery revealed statistically significant values between function and length of step, between pre- and postsurgery data for scores for function and length of step and Knee Score. The short-term results obtained are encouraging but only a long-term follow-up will be able to confirm the use of evaluating total knee replacement.noneE. Bergami; A. Gildone; G. Zanoli; L. Massari; G. C. TrainaBergami, Eleonora; Gildone, Alessandro; Zanoli, Gustavo Alberto; Massari, Leo; Traina, Gian Carl

    Percutaneous fixation and balloon kyphoplasty for the treatment of A3 thoracolumbar fractures

    No full text
    Background: Despite a long history of descriptive and clinical series, there is still no consensus in the treatment of traumatic thoracolumbar fractures. It is now widely accepted that percutaneous surgery in thoracolumbar spine trauma management can achieve the same results as conventional treatment but less morbidity but it is still not clear which are the best indications for these minimal invasive procedures. Methods: Thirty-two adult patients with single type A3 thoracolumbar burst fractures without neurologic deficits were included in this retrospective review of clinical and radiological outcomes after surgical management. All patients underwent combined percutaneous kyphoplasty and short fixation with screws in the vertebral pedicles above and below the fracture. Radiographic evaluation of segmental kyphosis and local kyphotic corrections were made preoperatively, 3 days postoperatively, 12 months post-operatively and at the last follow-up (the mean last follow-up was 41 months post-operatively). Clinical outcomes were determined by SF-36® Health Survey and Oswestry Disability Index scores at 3-month and 12-month follow-ups. Results: Clinical assessments suggested good outcomes as early as the third postoperative month. The clinical outcomes were sustained at one year follow-up. At the last follow-up the segmental kyphosis correction and local kyphotic correction were maintained. Conclusions: Our analysis demonstrates that minimally invasive kyphoplasty and percutaneous short fixation applied to thoracolumbar A3 burst fractures without neurological deficit may achieve results comparable to nonsurgical or open surgical treatment, but with less morbidity and complication, and should be considered as a valid treatment option

    Can TAD and CalTAD predict cut-out after extra-medullary fixation with new generation devices of proximal femoral fractures? A retrospective study.

    No full text
    Background: Intramedullary and extramedullary strategies of pertrochanteric fracture fixation are still controversial, but new percutaneous devices may give advantages regarding operative time, blood loss and rate of cardiovascular complications. We retrospectively analyze our cases regarding Anteversa® plate (Intrauma, Turin, Italy) fixation of pertrochanteric femoral fractures, focusing on the correlation between two radiographical parameters (tip-apex distance “TAD” and calcar referenced tip-apex distance “CalTAD”) and the occurrence of cut-out. The purpose of this study was to determine if these predicting factors of cut-out are reliable in the treatment of proximal femoral fractures with the Anteversa plate. Methods: A series of 77 patients with 53 31-A1 fracture types and 24-A2 fractures completed a 12-month-follow-up. Clinical outcomes were evaluated according to Parker-Palmer Mobility Score at the final follow-up. TAD and CalTAD were considered to determine their correlation with cut-out events. Results: The mean Parker-Palmer Score was 6.94 in A1 group and 7.41 in A2 group (p = 0.47). Mean value of TAD index was 29.58, 29.81 in the A1 group and 29.08 in the A2 group, and mean value of CalTAD index was 30.87, 31.03 in the A1 group and 30.50 in the A2 group. We observed 3 cases of implant cut-out. We shared our sample in two groups, one group with TAD and CalTAD indices lower than 25 mm and another group higher than 25 mm to evaluate how the Palmer Parker score changed and no statistical differences were found between the two groups. Conclusions: Taking into consideration that good clinical results were obtained for TAD and CalTAD values superior to 25 mm, the prognostic value of 25 mm of TAD and CalTAD indices might not be appropriate to this new percutaneous plate

    Minimally invasive fixation techniques for thoracolumbar fractures: comparison between percutaneous pedicle screw with intermediate screw (PPSIS) and percutaneous pedicle screw with kyphoplasty (PPSK)

    No full text
    Purpose: To assess and compare the efficacy of two minimally invasive techniques (percutaneous pedicle screw with intermediate screw vs. percutaneous pedicle screw with kyphoplasty) for spinal fracture fixation by comparing the segmental kyphosis and vertebral kyphosis angles after trauma before surgery, after surgery, and at 4-month and 12-month follow-up. Methods: Data from 49 patients without neurological deficit treated by either percutaneous pedicle screw with intermediate screw or percutaneous pedicle screw with kyphoplasty were retrospectively analysed. The segmental kyphosis and vertebral kyphosis angles over time were calculated and correlated with the type of procedure, AO classification, lumbar or thoracic site and the age and sex of the patients. Results: After surgery, both techniques were found to be efficacious means of bringing about a significant correction of the segmental kyphosis angle (p = 0.002) and a just significant correction of the vertebral kyphosis angle (p = 0.06), although less effectively in thoracic fractures (p = 0.004). At follow-up, the vertebral kyphosis angle was stable in both groups, while there was a significant loss of segmental kyphosis angle stability in the percutaneous pedicle screw with kyphoplasty group at 1 year (p = 0.004); fractured thoracic vertebrae maintained a greater vertebral kyphosis angle (p = 0.06) and segmental kyphosis angle (p < 0.001), than the lumbar. Conclusion: At 1 year after surgery, the use of intermediate screws in fractured vertebrae seemed to maintain a more efficacious correction with respect to kyphoplasty, although thoracic fracture sites appear to be associated with greater post-traumatic segmental kyphosis and lesser stability in the long term after both percutaneous surgical techniques
    corecore