646 research outputs found

    Usability evaluation of a clinical decision support tool for osteoporosis disease management

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Osteoporosis affects over 200 million people worldwide at a high cost to healthcare systems. Although guidelines are available, patients are not receiving appropriate diagnostic testing or treatment. Findings from a systematic review of osteoporosis interventions and a series of focus groups were used to develop a functional multifaceted tool that can support clinical decision-making in osteoporosis disease management at the point of care. The objective of our study was to assess how well the prototype met functional goals and usability needs.</p> <p>Methods</p> <p>We conducted a usability study for each component of the tool--the Best Practice Recommendation Prompt (BestPROMPT), the Risk Assessment Questionnaire (RAQ), and the Customised Osteoporosis Education (COPE) sheet--using the framework described by Kushniruk and Patel. All studies consisted of one-on-one sessions with a moderator using a standardised worksheet. Sessions were audio- and video-taped and transcribed verbatim. Data analysis consisted of a combination of qualitative and quantitative analyses.</p> <p>Results</p> <p>In study 1, physicians liked that the BestPROMPT can provide customised recommendations based on risk factors identified from the RAQ. Barriers included lack of time to use the tool, the need to alter clinic workflow to enable point-of-care use, and that the tool may disrupt the real reason for the visit. In study 2, patients completed the RAQ in a mean of 6 minutes, 35 seconds. Of the 42 critical incidents, 60% were navigational and most occurred when the first nine participants were using the stylus pen; no critical incidents were observed with the last six participants that used the touch screen. Patients thought that the RAQ questions were easy to read and understand, but they found it difficult to initiate the questionnaire. Suggestions for improvement included improving aspects of the interface and navigation. The results of study 3 showed that most patients were able to understand and describe sections of the COPE sheet, and all considered discussing the information with their physicians. Suggestions for improvement included simplifying the language and improving the layout.</p> <p>Conclusions</p> <p>Findings from the three studies informed changes to the tool and confirmed the importance of usability testing on all end users to reduce errors, and as an important step in the development process of knowledge translation interventions.</p

    Group differences in physician responses to handheld presentation of clinical evidence: a verbal protocol analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To identify individual differences in physicians' needs for the presentation of evidence resources and preferences for mobile devices.</p> <p>Methods</p> <p>Within-groups analysis of responses to semi-structured interviews. Interviews consisted of using prototypes in response to task-based scenarios. The prototypes were implemented on two different form factors: a tablet style PC and a pocketPC. Participants were from three user groups: general internists, family physicians and medicine residents, and from two different settings: urban and semi-urban. Verbal protocol analysis, which consists of coding utterances, was conducted on the transcripts of the testing sessions. Statistical relationships were investigated between staff physicians' and residents' background variables, self-reported experiences with the interfaces, and verbal code frequencies.</p> <p>Results</p> <p>47 physicians were recruited from general internal medicine, family practice clinics and a residency training program. The mean age of participants was 42.6 years. Physician specialty had a greater effect on device and information-presentation preferences than gender, age, setting or previous technical experience. Family physicians preferred the screen size of the tablet computer and were less concerned about its portability. Residents liked the screen size of the tablet, but preferred the portability of the pocketPC. Internists liked the portability of the pocketPC, but saw less advantage to the large screen of the tablet computer (F[2,44] = 4.94, p = .012).</p> <p>Conclusion</p> <p>Different types of physicians have different needs and preferences for evidence-based resources and handheld devices. This study shows how user testing can be incorporated into the process of design to inform group-based customization.</p

    Energy Management of People in Organizations: A Review and Research Agenda

    Get PDF
    Although energy is a concept that is implied in many motivational theories, is hardly ever explicitly mentioned or researched. The current article first relates theories and research findings that were thus far not explicitly related to energy. We describe theories such as flow, subjective well-being, engagement and burn-out, and make the link with energy more explicit. Also, we make a first link between personality characteristics and energy, and describe the role of leadership in unleashing followers’ energy. Following, we identify how the topic of energy management can be profitably incorporated in research from a scientific as well as a practitioner viewpoint. Finally, we describe several interventions to enhance energy in individuals and organizations

    Model for screening of resonant magnetic perturbations by plasma in a realistic tokamak geometry and its impact on divertor strike points

    Full text link
    This work addresses the question of the relation between strike-point splitting and magnetic stochasticity at the edge of a poloidally diverted tokamak in the presence of externally imposed magnetic perturbations. More specifically, ad-hoc helical current sheets are introduced in order to mimic a hypothetical screening of the external resonant magnetic perturbations by the plasma. These current sheets, which suppress magnetic islands, are found to reduce the amount of splitting expected at the target, which suggests that screening effects should be observable experimentally. Multiple screening current sheets reinforce each other, i.e. less current relative to the case of only one current sheet is required to screen the perturbation.Comment: Accepted in the Proceedings of the 19th International Conference on Plasma Surface Interactions, to be published in Journal of Nuclear Materials. Version 2: minor formatting and text improvements, more results mentioned in the conclusion and abstrac

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Modelling of the effect of ELMs on fuel retention at the bulk W divertor of JET

    Get PDF
    Effect of ELMs on fuel retention at the bulk W target of JET ITER-Like Wall was studied with multi-scale calculations. Plasma input parameters were taken from ELMy H-mode plasma experiment. The energetic intra-ELM fuel particles get implanted and create near-surface defects up to depths of few tens of nm, which act as the main fuel trapping sites during ELMs. Clustering of implantation-induced vacancies were found to take place. The incoming flux of inter-ELM plasma particles increases the different filling levels of trapped fuel in defects. The temperature increase of the W target during the pulse increases the fuel detrapping rate. The inter-ELM fuel particle flux refills the partially emptied trapping sites and fills new sites. This leads to a competing effect on the retention and release rates of the implanted particles. At high temperatures the main retention appeared in larger vacancy clusters due to increased clustering rate

    Overview of the JET ITER-like wall divertor

    Get PDF

    Impact of fast ions on density peaking in JET: fluid and gyrokinetic modeling

    Get PDF
    The effect of fast ions on turbulent particle transport, driven by ion temperature gradient (ITG)/ trapped electron mode turbulence, is studied. Two neutral beam injection (NBI) heated JET discharges in different regimes are analyzed at the radial position ρt_{t}=0.6, one of them an L-mode and the other one an H-mode discharge. Results obtained from the computationally efficient fluid model EDWM and the gyro-fluid model TGLF are compared to linear and nonlinear gyrokinetic GENE simulations as well as the experimentally obtained density peaking. In these models, the fast ions are treated as a dynamic species with a Maxwellian background distribution. The dependence of the zero particle flux density gradient (peaking factor) on fast ion density, temperature and corresponding gradients, is investigated. The simulations show that the inclusion of a fast ion species has a stabilizing influence on the ITG mode and reduces the peaking of the main ion and electron density profiles in the absence of sources. The models mostly reproduce the experimentally obtained density peaking for the L-mode discharge whereas the H-mode density peaking is significantly underpredicted, indicating the importance of the NBI particle source for the H-mode density profile

    Current Research into Applications of Tomography for Fusion Diagnostics

    Get PDF
    Retrieving spatial distribution of plasma emissivity from line integrated measurements on tokamaks presents a challenging task due to ill-posedness of the tomography problem and limited number of the lines of sight. Modern methods of plasma tomography therefore implement a-priori information as well as constraints, in particular some form of penalisation of complexity. In this contribution, the current tomography methods under development (Tikhonov regularisation, Bayesian methods and neural networks) are briefly explained taking into account their potential for integration into the fusion reactor diagnostics. In particular, current development of the Minimum Fisher Regularisation method is exemplified with respect to real-time reconstruction capability, combination with spectral unfolding and other prospective tasks
    corecore