42 research outputs found

    Spine curvature analysis between participants with obesity and normal weight participants: a biplanar electromagnetic device measurement.

    Get PDF
    UNLABELLED: To analyse and compare standing thoracolumbar curves in normal weight participants and participants with obesity, using an electromagnetic device, and to analyse the measurement reliability. MATERIAL AND METHODS: Cross-sectional study was carried out. 36 individuals were divided into two groups (normal-weight and participants with obesity) according to their waist circumference. The reference points (T1-T8-L1-L5 and both posterior superior iliac spines) were used to perform a description of thoracolumbar curvature in the sagittal and coronal planes. A transformation from the global coordinate system was performed and thoracolumbar curves were adjusted by fifth-order polynomial equations. The tangents of the first and fifth lumbar vertebrae and the first thoracic vertebra were determined from their derivatives. The reliability of the measurement was assessed according to the internal consistency of the measure and the thoracolumbar curvature angles were compared between groups. RESULTS: Cronbach's alpha values ranged between 0.824 (95% CI: 0.776-0.847) and 0.918 (95% CI: 0.903-0.949). In the coronal plane, no significant differences were found between groups; however, in sagittal plane, significant differences were observed for thoracic kyphosis. CONCLUSION: There were significant differences in thoracic kyphosis in the sagittal plane between two groups of young adults grouped according to their waist circumference

    Inertial sensor real-time feedback enhances the learning of cervical spine manipulation: a prospective study.

    Get PDF
    BACKGROUND: Cervical Spinal Manipulation (CSM) is considered a high-level skill of the central nervous system because it requires bimanual coordinated rhythmical movements therefore necessitating training to achieve proficiency. The objective of the present study was to investigate the effect of real-time feedback on the performance of CSM. METHODS: Six postgraduate physiotherapy students attending a training workshop on Cervical Spine Manipulation Technique (CSMT) using inertial sensor derived real-time feedback participated in this study. The key variables were pre-manipulative position, angular displacement of the thrust and angular velocity of the thrust. Differences between variables before and after training were investigated using t-tests. RESULTS: There were no significant differences after training for the pre-manipulative position (rotation p = 0.549; side bending p = 0.312) or for thrust displacement (rotation p = 0.247; side bending p = 0.314). Thrust angular velocity demonstrated a significant difference following training for rotation (pre-training mean (sd) 48.9°/s (35.1); post-training mean (sd) 96.9°/s (53.9); p = 0.027) but not for side bending (p = 0.521). CONCLUSION: Real-time feedback using an inertial sensor may be valuable in the development of specific manipulative skill. Future studies investigating manipulation could consider a randomized controlled trial using inertial sensor real time feedback compared to traditional training

    Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review.

    Get PDF
    Background: Wearable sensors are portable measurement tools that are becoming increasingly popular for the measurement of joint angle in the upper limb. With many brands emerging on the market, each with variations in hardware and protocols, evidence to inform selection and application is needed. Therefore, the objectives of this review were related to the use of wearable sensors to calculate upper limb joint angle. We aimed to describe (i) the characteristics of commercial and custom wearable sensors, (ii) the populations for whom researchers have adopted wearable sensors, and (iii) their established psychometric properties. Methods: A systematic review of literature was undertaken using the following data bases: MEDLINE, EMBASE, CINAHL, Web of Science, SPORTDiscus, IEEE, and Scopus. Studies were eligible if they met the following criteria: (i) involved humans and/or robotic devices, (ii) involved the application or simulation of wearable sensors on the upper limb, and (iii) calculated a joint angle. Results: Of 2191 records identified, 66 met the inclusion criteria. Eight studies compared wearable sensors to a robotic device and 22 studies compared to a motion analysis system. Commercial (n = 13) and custom (n = 7) wearable sensors were identified, each with variations in placement, calibration methods, and fusion algorithms, which were demonstrated to influence accuracy. Conclusion: Wearable sensors have potential as viable instruments for measurement of joint angle in the upper limb during active movement. Currently, customised application (i.e. calibration and angle calculation methods) is required to achieve sufficient accuracy (error < 5°). Additional research and standardisation is required to guide clinical application

    Functional parameters indicative of mild cognitive impairment: a systematic review using instrumented kinematic assessment

    Get PDF
    Background: Patients with mild cognitive impairment (MCI) experience alterations of functional parameters, such as an impaired balance or gait. The current systematic review set out to investigate whether functional objective performance may predict a future risk of MCI; to compare functional objective parameters in patients with MCI and a control group; and to assess changes in these parameters after different physical activity interventions. Methods: Electronic databases, including PubMed, AMED, CINAHL, EMBASE, PEDro and Web of Science as well as grey literature databases, were searched from inception to February 2020. Cohort studies and Randomized Controlled Trials (RCTs) were included. The risk of bias of the included studies was assessed independently by reviewers using quality assessment checklists. The level of evidence per outcome was assessed using the GRADE criteria. Results: Seventeen studies met inclusion criteria including patients with MCI. Results from RCTs suggested that gait speed, gait variability and balance may be improved by different physical activity interventions. Cohort studies showed that slower gait speed, above all, under Dual Task (DT) conditions, was the main impaired parameter in patients with MCI in comparison with a Control Gorup. Furthermore, cohort studies suggested that gait variability could predict an incident MCI. Although most of included cohort studies reported low risk of bias, RCTs showed an unclear risk of bias. Conclusions: Studies suggest that gait variability may predict an incident MCI. Moreover, different gait parameters, above all under DT conditions, could be impaired in patients with MCI. These parameters could be improved by some physical activity interventions. Although cohort studies reported low risk of bias, RCTs showed an unclear risk of bias and GRADE criteria showed a low level of evidence per outcome, so further studies are required to refute our findings

    Multiancestry analysis of the HLA locus in Alzheimer’s and Parkinson’s diseases uncovers a shared adaptive immune response mediated by HLA-DRB1*04 subtypes

    Get PDF
    Across multiancestry groups, we analyzed Human Leukocyte Antigen (HLA) associations in over 176,000 individuals with Parkinson’s disease (PD) and Alzheimer’s disease (AD) versus controls. We demonstrate that the two diseases share the same protective association at the HLA locus. HLA-specific fine-mapping showed that hierarchical protective effects of HLA-DRB1*04 subtypes best accounted for the association, strongest with HLA-DRB1*04:04 and HLA-DRB1*04:07, and intermediary with HLA-DRB1*04:01 and HLA-DRB1*04:03. The same signal was associated with decreased neurofibrillary tangles in postmortem brains and was associated with reduced tau levels in cerebrospinal fluid and to a lower extent with increased Aβ42. Protective HLA-DRB1*04 subtypes strongly bound the aggregation-prone tau PHF6 sequence, however only when acetylated at a lysine (K311), a common posttranslational modification central to tau aggregation. An HLA-DRB1*04-mediated adaptive immune response decreases PD and AD risks, potentially by acting against tau, offering the possibility of therapeutic avenues
    corecore