155 research outputs found

    The need for multidisciplinarity in specialist training to optimize future patient care

    Get PDF
    Harmonious interactions between radiation, medical, interventional and surgical oncologists, as well as other members of multidisciplinary teams, are essential for the optimization of patient care in oncology. This multidisciplinary approach is particularly important in the current landscape, in which standard-of-care approaches to cancer treatment are evolving towards highly targeted treatments, precise image guidance and personalized cancer therapy. Herein, we highlight the importance of multidisciplinarity and interdisciplinarity at all levels of clinical oncology training. Potential deficits in the current career development pathways and suggested strategies to broaden clinical training and research are presented, with specific emphasis on the merits of trainee involvement in functional multidisciplinary teams. Finally, the importance of training in multidisciplinary research is discussed, with the expectation that this awareness will yield the most fertile ground for future discoveries. Our key message is for cancer professionals to fulfil their duty in ensuring that trainees appreciate the importance of multidisciplinary research and practice

    The Dandelion Dilemma Revisited for Oligoprogression: Treat the Whole Lawn or Weed Selectively?

    Get PDF
    Oligoprogressive disease is a relatively new clinical concept describing progression at only a few sites of metastasis in patients with otherwise controlled widespread disease. In the era of well-tolerated targeted treatments, resistance inevitably occurs and overcoming this is a challenge. Local ablative therapy for oligoprogressive disease may allow the continuation of systemic treatments by overcoming the few sub-clones that have developed resistance. Stereotactic body radiotherapy is now frequently used in treating oligometastatic disease using ablative doses with minimally invasive techniques and acceptable toxicity. We discuss the current retrospective clinical evidence base supporting the use of local ablative therapy for oligoprogression in metastatic patients on targeted treatments within multiple tumour sites. As there is currently a lack of published prospective data available, the best management for these patients remains unclear. We discuss current trials in recruitment and the potential advancements in treating this group of patients with stereotactic radiotherapy

    The delineation of intraprostatic boost regions for radiotherapy using multimodality imaging.

    Get PDF
    Dose escalation to the prostate improves tumor control but at the expense of increased rectal toxicity. Modern imaging can be used to detect the most common site of recurrence, the intraprostatic lesion (IPL), which has led to the concept of focusing dose escalation to the IPL in order to improve the therapeutic ratio. Imaging must be able to detect lesions with adequate sensitivity and specificity to accurately delineate the IPL. This information must be carefully integrated into the radiotherapy planning process to ensure the dose is targeted to the IPL. This review will consider the role and challenges of multiparametric MRI and PET computed tomography in delineating a tumor boost to be delivered by external beam radiotherapy

    Improving 3D ultrasound prostate localisation in radiotherapy through increased automation of interfraction matching.

    Get PDF
    Background and purpose Daily image guidance is standard care for prostate radiotherapy. Innovations which improve the accuracy and efficiency of ultrasound guidance are needed, particularly with respect to reducing interobserver variation. This study explores automation tools for this purpose, demonstrated on the Elekta Clarity Autoscan®. The study was conducted as part of the Clarity-Pro trial (NCT02388308). Materials and methods Ultrasound scan volumes were collected from 32 patients. Prostate matches were performed using two proposed workflows and the results compared with Clarity's proprietary software. Gold standard matches derived from manually localised landmarks provided a reference. The two workflows incorporated a custom 3D image registration algorithm, which was benchmarked against a third-party application (Elastix). Results Significant reductions in match errors were reported from both workflows compared to standard protocol. Median (IQR) absolute errors in the left-right, anteroposterior and craniocaudal axes were lowest for the Manually Initiated workflow: 0.7(1.0) mm, 0.7(0.9) mm, 0.6(0.9) mm compared to 1.0(1.7) mm, 0.9(1.4) mm, 0.9(1.2) mm for Clarity. Median interobserver variation was ≪0.01 mm in all axes for both workflows compared to 2.2 mm, 1.7 mm, 1.5 mm for Clarity in left-right, anteroposterior and craniocaudal axes. Mean matching times was also reduced to 43 s from 152 s for Clarity. Inexperienced users of the proposed workflows attained better match precision than experienced users on Clarity. Conclusion Automated image registration with effective input and verification steps should increase the efficacy of interfraction ultrasound guidance compared to the current commercially available tools

    Kinetic CRAC uncovers a role for Nab3 in determining gene expression profiles during stress

    Get PDF
    RNA-binding proteins play a key role in shaping gene expression profiles during stress, however, little is known about the dynamic nature of these interactions and how this influences the kinetics of gene expression. To address this, we developed kinetic cross-linking and analysis of cDNAs (\u3c7CRAC), an ultraviolet cross-linking method that enabled us to quantitatively measure the dynamics of protein\u2013RNA interactions in vivo on a minute time-scale. Here, using \u3c7CRAC we measure the global RNA-binding dynamics of the yeast transcription termination factor Nab3 in response to glucose starvation. These measurements reveal rapid changes in protein\u2013RNA interactions within 1\u2009min following stress imposition. Changes in Nab3 binding are largely independent of alterations in transcription rate during the early stages of stress response, indicating orthogonal transcriptional control mechanisms. We also uncover a function for Nab3 in dampening expression of stress-responsive genes. \u3c7CRAC has the potential to greatly enhance our understanding of in vivo dynamics of protein\u2013RNA interactions

    Improving fiducial and prostate capsule visualization for radiotherapy planning using MRI.

    Get PDF
    Background and purpose Intraprostatic fiducial markers (FM) improve the accuracy of radiotherapy (RT) delivery. Here we assess geometric integrity and contouring consistency using a T2*-weighted (T2*W) sequence alone, which allows visualization of the FM.Material and methods Ten patients scanned within the Prostate Advances in Comparative Evidence (PACE) trial (NCT01584258) had prostate images acquired with computed tomography (CT) and Magnetic Resonance (MR) Imaging: T2-weighted (T2W) and T2*W sequences. The prostate was contoured independently on each imaging dataset by three clinicians. Interobserver variability was assessed using comparison indices with Monaco ADMIRE (research version 2.0, Elekta AB) and examined for statistical differences between imaging sets. CT and MR images of two test objects were acquired to assess geometric distortion and accuracy of marker positioning. The first was a linear test object comprising straight tubes in three orthogonal directions, the second was a smaller test object with markers suspended in gel.Results Interobserver variability for prostate contouring was lower for both T2W and T2*W compared to CT, this was statistically significant when comparing CT and T2*W images. All markers are visible in T2*W images with 29/30 correctly identified, only 3/30 are visible in T2W images. Assessment of geometric distortion revealed in-plane displacements were under 0.375 mm in MRI, and through plane displacements could not be detected. The signal loss in the MR images is symmetric in relation to the true marker position shown in CT images.Conclusion Prostate T2*W images are geometrically accurate, and yield consistent prostate contours. This single sequence can be used to identify FM and for prostate delineation in a mixed MR-CT workflow

    Gastrointestinal Toxicity Prediction Not Influenced by Rectal Contour or Dose-Volume Histogram Definition.

    Get PDF
    PURPOSE: Rectal dose delivered during prostate radiation therapy is associated with gastrointestinal toxicity. Treatment plans are commonly optimized using rectal dose-volume constraints, often whole-rectum relative-volumes (%). We investigated whether improved rectal contouring, use of absolute-volumes (cc), or rectal truncation might improve toxicity prediction. METHODS AND MATERIALS: Patients from the CHHiP trial (receiving 74 Gy/37 fractions [Fr] vs 60 Gy/20 Fr vs 57 Gy/19 Fr) were included if radiation therapy plans were available (2350/3216 patients), plus toxicity data for relevant analyses (2170/3216 patients). Whole solid rectum relative-volumes (%) dose-volume-histogram (DVH), as submitted by treating center (original contour), was assumed standard-of-care. Three investigational rectal DVHs were generated: (1) reviewed contour per CHHiP protocol; (2) original contour absolute volumes (cc); and (3) truncated original contour (2 versions; ±0 and ±2 cm from planning target volume [PTV]). Dose levels of interest (V30, 40, 50, 60, 70, 74 Gy) in 74 Gy arm were converted by equivalent-dose-in-2 Gy-Fr (EQD2α/β= 3 Gy) for 60 Gy/57 Gy arms. Bootstrapped logistic models predicting late toxicities (frequency G1+/G2+, bleeding G1+/G2+, proctitis G1+/G2+, sphincter control G1+, stricture/ulcer G1+) were compared by area-undercurve (AUC) between standard of care and the 3 investigational rectal definitions. RESULTS: The alternative dose/volume parameters were compared with the original relative-volume (%) DVH of the whole rectal contour, itself fitted as a weak predictor of toxicity (AUC range, 0.57-0.65 across the 8 toxicity measures). There were no significant differences in toxicity prediction for: (1) original versus reviewed rectal contours (AUCs, 0.57-0.66; P = .21-.98); (2) relative- versus absolute-volumes (AUCs, 0.56-0.63; P = .07-.91); and (3) whole-rectum versus truncation at PTV ± 2 cm (AUCs, 0.57-0.65; P = .05-.99) or PTV ± 0 cm (AUCs, 0.57-0.66; P = .27-.98). CONCLUSIONS: We used whole-rectum relative-volume DVH, submitted by the treating center, as the standard-of-care dosimetric predictor for rectal toxicity. There were no statistically significant differences in prediction performance when using central rectal contour review, with the use of absolute-volume dosimetry, or with rectal truncation relative to PTV. Whole-rectum relative-volumes were not improved upon for toxicity prediction and should remain standard-of-care

    In Vivo Validation of Elekta's Clarity Autoscan for Ultrasound-based Intrafraction Motion Estimation of the Prostate During Radiation Therapy.

    Get PDF
    PURPOSE:Our purpose was to perform an in vivo validation of ultrasound imaging for intrafraction motion estimation using the Elekta Clarity Autoscan system during prostate radiation therapy. The study was conducted as part of the Clarity-Pro trial (NCT02388308). METHODS AND MATERIALS:Initial locations of intraprostatic fiducial markers were identified from cone beam computed tomography scans. Marker positions were translated according to Clarity intrafraction 3-dimensional prostate motion estimates. The updated locations were projected onto the 2-dimensional electronic portal imager plane. These Clarity-based estimates were compared with the actual portal-imaged 2-dimensional marker positions. Images from 16 patients encompassing 80 fractions were analyzed. To investigate the influence of intraprostatic markers and image quality on ultrasound motion estimation, 3 observers rated image quality, and the marker visibility on ultrasound images was assessed. RESULTS:The median difference between Clarity-defined intrafraction marker locations and portal-imaged marker locations was 0.6 mm (with 95% limit of agreement at 2.5 mm). Markers were identified on ultrasound in only 3 of a possible 240 instances. No linear relationship between image quality and Clarity motion estimation confidence was identified. The difference between Clarity-based motion estimates and electronic portal-imaged marker location was also independent of image quality. Clarity estimation confidence was degraded in a single fraction owing to poor probe placement. CONCLUSIONS:The accuracy of Clarity intrafraction prostate motion estimation is comparable with that of other motion-monitoring systems in radiation therapy. The effect of fiducial markers in the study was deemed negligible as they were rarely visible on ultrasound images compared with intrinsic anatomic features. Clarity motion estimation confidence was robust to variations in image quality and the number of ultrasound-imaged anatomic features; however, it was degraded as a result of poor probe placement

    Interim Toxicity Analysis From the Randomized HERMES Trial of 2- and 5-Fraction Magnetic Resonance Imaging-Guided Adaptive Prostate Radiation Therapy.

    Get PDF
    PURPOSE: Ultrahypofractionated radiation therapy (UHRT) is an effective treatment for localized prostate cancer with an acceptable toxicity profile; boosting the visible intraprostatic tumor has been shown to improve biochemical disease-free survival with no significant effect on genitourinary (GU) and gastrointestinal (GI) toxicity. METHODS AND MATERIALS: HERMES is a single-center noncomparative randomized phase 2 trial in men with intermediate or lower high risk prostate cancer. Patients were allocated (1:1) to 36.25 Gy in 5 fractions over 2 weeks or 24 Gy in 2 fractions over 8 days with an integrated boost to the magnetic resonance imaging (MRI) visible tumor of 27 Gy in 2 fractions. A minimization algorithm with a random element with risk group as a balancing factor was used for participant randomization. Treatment was delivered on the Unity MR-Linac (Elekta AB) with daily online adaption. The primary endpoint was acute GU Common Terminology Criteria for Adverse Events version 5.0 toxicity with the aim of excluding a doubling of the rate of acute grade 2+ GU toxicity seen in PACE. Analysis was by treatment received and included all participants who received at least 1 fraction of study treatment. This interim analysis was prespecified (stage 1 of a 2-stage Simon design) for when 10 participants in each treatment group had completed the acute toxicity monitoring period (12 weeks after radiation therapy). RESULTS: Acute grade 2 GU toxicity was reported in 1 (10%) patient in the 5-fraction group and 2 (20%) patients in the 2-fraction group. No grade 3+ GU toxicities were reported. CONCLUSIONS: At this interim analysis, the rate of GU toxicity in the 2-fraction and 5-fraction treatment groups was found to be below the prespecified threshold (5/10 grade 2+) and continuation of the study to complete recruitment of 23 participants per group was recommended
    corecore