11,733 research outputs found

    K-Space at TRECVid 2008

    Get PDF
    In this paper we describe K-Space’s participation in TRECVid 2008 in the interactive search task. For 2008 the K-Space group performed one of the largest interactive video information retrieval experiments conducted in a laboratory setting. We had three institutions participating in a multi-site multi-system experiment. In total 36 users participated, 12 each from Dublin City University (DCU, Ireland), University of Glasgow (GU, Scotland) and Centrum Wiskunde & Informatica (CWI, the Netherlands). Three user interfaces were developed, two from DCU which were also used in 2007 as well as an interface from GU. All interfaces leveraged the same search service. Using a latin squares arrangement, each user conducted 12 topics, leading in total to 6 runs per site, 18 in total. We officially submitted for evaluation 3 of these runs to NIST with an additional expert run using a 4th system. Our submitted runs performed around the median. In this paper we will present an overview of the search system utilized, the experimental setup and a preliminary analysis of our results

    K-Space at TRECVID 2008

    Get PDF
    In this paper we describe K-Space’s participation in TRECVid 2008 in the interactive search task. For 2008 the K-Space group performed one of the largest interactive video information retrieval experiments conducted in a laboratory setting. We had three institutions participating in a multi-site multi-system experiment. In total 36 users participated, 12 each from Dublin City University (DCU, Ireland), University of Glasgow (GU, Scotland) and Centrum Wiskunde and Informatica (CWI, the Netherlands). Three user interfaces were developed, two from DCU which were also used in 2007 as well as an interface from GU. All interfaces leveraged the same search service. Using a latin squares arrangement, each user conducted 12 topics, leading in total to 6 runs per site, 18 in total. We officially submitted for evaluation 3 of these runs to NIST with an additional expert run using a 4th system. Our submitted runs performed around the median. In this paper we will present an overview of the search system utilized, the experimental setup and a preliminary analysis of our results

    The Effectiveness of Data Augmentation for Detection of Gastrointestinal Diseases from Endoscopical Images

    Full text link
    The lack, due to privacy concerns, of large public databases of medical pathologies is a well-known and major problem, substantially hindering the application of deep learning techniques in this field. In this article, we investigate the possibility to supply to the deficiency in the number of data by means of data augmentation techniques, working on the recent Kvasir dataset of endoscopical images of gastrointestinal diseases. The dataset comprises 4,000 colored images labeled and verified by medical endoscopists, covering a few common pathologies at different anatomical landmarks: Z-line, pylorus and cecum. We show how the application of data augmentation techniques allows to achieve sensible improvements of the classification with respect to previous approaches, both in terms of precision and recall

    A SVM-Based Multi-Resolution Procedure for the Estimation of the DOAS of Interfering Signals in a Communication System

    Get PDF
    In this work, the use of a planar antenna system for the estimation of the directions of arrivals (DOAs) of multiple signals impinging on the receiver has been considered. Towards this end, an efficient multi-resolution method based on a SVM-classifier is proposed for determining a probabilitic map of the DOAs of the unknown interfering signals. Numerical results dealing with multiple interferers scenarios in noisy environments are provided in order to assess the feasibility as well as the capability of the proposed approach

    Overcoming Inter-Subject Variability in BCI Using EEG-Based Identification

    Get PDF
    The high dependency of the Brain Computer Interface (BCI) system performance on the BCI user is a well-known issue of many BCI devices. This contribution presents a new way to overcome this problem using a synergy between a BCI device and an EEG-based biometric algorithm. Using the biometric algorithm, the BCI device automatically identifies its current user and adapts parameters of the classification process and of the BCI protocol to maximize the BCI performance. In addition to this we present an algorithm for EEG-based identification designed to be resistant to variations in EEG recordings between sessions, which is also demonstrated by an experiment with an EEG database containing two sessions recorded one year apart. Further, our algorithm is designed to be compatible with our movement-related BCI device and the evaluation of the algorithm performance took place under conditions of a standard BCI experiment. Estimation of the mu rhythm fundamental frequency using the Frequency Zooming AR modeling is used for EEG feature extraction followed by a classifier based on the regularized Mahalanobis distance. An average subject identification score of 96 % is achieved

    Automatic Segmentation of Fluorescence Lifetime Microscopy Images of Cells Using Multi-Resolution Community Detection

    Full text link
    We have developed an automatic method for segmenting fluorescence lifetime (FLT) imaging microscopy (FLIM) images of cells inspired by a multi-resolution community detection (MCD) based network segmentation method. The image processing problem is framed as identifying segments with respective average FLTs against a background in FLIM images. The proposed method segments a FLIM image for a given resolution of the network composed using image pixels as the nodes and similarity between the pixels as the edges. In the resulting segmentation, low network resolution leads to larger segments and high network resolution leads to smaller segments. Further, the mean-square error (MSE) in estimating the FLT segments in a FLIM image using the proposed method was found to be consistently decreasing with increasing resolution of the corresponding network. The proposed MCD method outperformed a popular spectral clustering based method in performing FLIM image segmentation. The spectral segmentation method introduced noisy segments in its output at high resolution. It was unable to offer a consistent decrease in MSE with increasing resolution.Comment: 21 pages, 6 figure

    From Codes to Patterns: Designing Interactive Decoration for Tableware

    Full text link
    ABSTRACT We explore the idea of making aesthetic decorative patterns that contain multiple visual codes. We chart an iterative collaboration with ceramic designers and a restaurant to refine a recognition technology to work reliably on ceramics, produce a pattern book of designs, and prototype sets of tableware and a mobile app to enhance a dining experience. We document how the designers learned to work with and creatively exploit the technology, enriching their patterns with embellishments and backgrounds and developing strategies for embedding codes into complex designs. We discuss the potential and challenges of interacting with such patterns. We argue for a transition from designing ‘codes to patterns’ that reflects the skills of designers alongside the development of new technologies

    Scale Stain: Multi-Resolution Feature Enhancement in Pathology Visualization

    Full text link
    Digital whole-slide images of pathological tissue samples have recently become feasible for use within routine diagnostic practice. These gigapixel sized images enable pathologists to perform reviews using computer workstations instead of microscopes. Existing workstations visualize scanned images by providing a zoomable image space that reproduces the capabilities of the microscope. This paper presents a novel visualization approach that enables filtering of the scale-space according to color preference. The visualization method reveals diagnostically important patterns that are otherwise not visible. The paper demonstrates how this approach has been implemented into a fully functional prototype that lets the user navigate the visualization parameter space in real time. The prototype was evaluated for two common clinical tasks with eight pathologists in a within-subjects study. The data reveal that task efficiency increased by 15% using the prototype, with maintained accuracy. By analyzing behavioral strategies, it was possible to conclude that efficiency gain was caused by a reduction of the panning needed to perform systematic search of the images. The prototype system was well received by the pathologists who did not detect any risks that would hinder use in clinical routine
    corecore