486 research outputs found

    Detection and Prediction of Epileptic Seizures

    Get PDF

    A Hidden Markov Factor Analysis Framework for Seizure Detection in Epilepsy Patients

    Get PDF
    Approximately 1% of the world population suffers from epilepsy. Continuous long-term electroencephalographic (EEG) monitoring is the gold-standard for recording epileptic seizures and assisting in the diagnosis and treatment of patients with epilepsy. Detection of seizure from the recorded EEG is a laborious, time consuming and expensive task. In this study, we propose an automated seizure detection framework to assist electroencephalographers and physicians with identification of seizures in recorded EEG signals. In addition, an automated seizure detection algorithm can be used for treatment through automatic intervention during the seizure activity and on time triggering of the injection of a radiotracer to localize the seizure activity. In this study, we developed and tested a hidden Markov factor analysis (HMFA) framework for automated seizure detection based on different features such as total effective inflow which is calculated based on connectivity measures between different sites of the brain. The algorithm was tested on long-term (2.4-7.66 days) continuous sEEG recordings from three patients and a total of 16 seizures, producing a mean sensitivity of 96.3% across all seizures, a mean specificity of 3.47 false positives per hour, and a mean latency of 3.7 seconds form the actual seizure onset. The latency was negative for a few of the seizures which implies the proposed method detects the seizure prior to its onset. This is an indication that with some extension the proposed method is capable of seizure prediction

    Predicción de ataque epiléptico usando entropía espectral

    Get PDF
    El objetivo de este trabajo es evaluar la viabilidad de la entropía como instrumento para detectar precursores que permitan predecir un ataque epiléptico. Con esta finalidad se midió la entropía del espectro Fourier de la señal encefalográfica desde 0,5 hasta 32 minutos previos al ataque.Centro de Técnicas Analógico-Digitale

    Identifikasi dan Klasifikasi Sinyal EEG terhadap Rangsangan Suara dengan Ekstraksi Wavelet dan Spektral Daya

    Get PDF
    In this research the development of identification and classification technique of three wave components of EEG signal, named alpha, beta and theta, is considered. The technique is combination of wavelet transform and power spectral analysis. Wavelet transform was used to extract the wave components so it reduces the data without loss of the information. The wavelet transform also reduces the aspects of non-stationary of the EEG signal. The EEG's wave classification was based on the appearance of the wave, synchronization between symmetric hemispheres, and the wave energy dominance, in its frequency region. The EEG signals used in this research were obtained from 5 individually-independent subjects after 2.5 minutes sound stimulation. 10 sounds of music and 2 natural sounds were used as sound stimulation in this research. Then, 16 channels of EEG signals, obtained from every individual subject after a sound stimulation, were analyzed. The technique shows that the sound stimulation increases the appearance of the alpha wave by 75% and decreases beta and theta waves by 48% and 56%, respectively. Furthermore, the sound stimulations were used in the research to increase the synchronization balance between symmetric channels by 75%. In addition, this research shows that the signal extraction using wavelet packet provided small deviation and reduced non-stationary aspects, so that it improves the power spectral analysis used in the technique

    Epilepsy

    Get PDF
    With the vision of including authors from different parts of the world, different educational backgrounds, and offering open-access to their published work, InTech proudly presents the latest edited book in epilepsy research, Epilepsy: Histological, electroencephalographic, and psychological aspects. Here are twelve interesting and inspiring chapters dealing with basic molecular and cellular mechanisms underlying epileptic seizures, electroencephalographic findings, and neuropsychological, psychological, and psychiatric aspects of epileptic seizures, but non-epileptic as well

    Epileptic Seizures and the EEG

    Get PDF
    A study of epilepsy from an engineering perspective, this volume begins by summarizing the physiology and the fundamental ideas behind the measurement, analysis and modeling of the epileptic brain. It introduces the EEG and provides an explanation of the type of brain activity likely to register in EEG measurements, offering an overview of how these EEG records are and have been analyzed in the past. The book focuses on the problem of seizure detection and surveys the physiologically based dynamic models of brain activity. Finally, it addresses the fundamental question: can seizures be predicted? Based on the authors' extensive research, the book concludes by exploring a range of future possibilities in seizure prediction

    Epileptic Seizures and the EEG

    Get PDF
    A study of epilepsy from an engineering perspective, this volume begins by summarizing the physiology and the fundamental ideas behind the measurement, analysis and modeling of the epileptic brain. It introduces the EEG and provides an explanation of the type of brain activity likely to register in EEG measurements, offering an overview of how these EEG records are and have been analyzed in the past. The book focuses on the problem of seizure detection and surveys the physiologically based dynamic models of brain activity. Finally, it addresses the fundamental question: can seizures be predicted? Based on the authors' extensive research, the book concludes by exploring a range of future possibilities in seizure prediction

    Infraslow fluctuations and respiration are driving cortical neurophysiological oscillations during sleep

    Get PDF
    Abstract. Recently sleep has been linked to increased brain clearance through perivascular spaces from blood-brain barrier (BBB) externa limitans, facilitated by physiological pulsations such as cardiovascular and respiratory pulsations. Infraslow fluctuations (ISFs) characterize both fMRI BOLD signals and scalp EEG potentials. They are associated with both permeability fluctuations of BBB and the amplitude dynamics of faster (> 1Hz) neuronal oscillations. ISF together with respiration are though to synchronize with neural rhythms, however the directionality of these interactions has not been studied before. I used non-invasive measures which are necessary not to interfere the pressure sensitive CSF convection and BBB permeability combined with directional metrics to fully evaluate these relationships. I recorded full-band resting state EEG (fbEEG) during wakefulness and sleep and investigated whether recently shown increased brain clearance during sleep is followed by increased drive of neural amplitudes by the ISF and respiration phases. I show that ISF power increases during non-REM sleep, possibly reflecting altered BBB status. Furthermore, I show that ISF and respiration phase-amplitude couple and predict neuronal brain rhythms seen especially during sleep. These results pave the way for understanding the mechanisms how neuronal activity is modulated by the slow oscillations in human brain during wakefulness and sleep

    A Research Platform for Artificial Neural Networks with Applications in Pediatric Epilepsy

    Get PDF
    This dissertation established a state-of-the-art programming tool for designing and training artificial neural networks (ANNs) and showed its applicability to brain research. The developed tool, called NeuralStudio, allows users without programming skills to conduct studies based on ANNs in a powerful and very user friendly interface. A series of unique features has been implemented in NeuralStudio, such as ROC analysis, cross-validation, network averaging, topology optimization, and optimization of the activation function’s slopes. It also included a Support Vector Machines module for comparison purposes. Once the tool was fully developed, it was applied to two studies in brain research. In the first study, the goal was to create and train an ANN to detect epileptic seizures from subdural EEG. This analysis involved extracting features from the spectral power in the gamma frequencies. In the second application, a unique method was devised to link EEG recordings to epileptic and non-epileptic subjects. The contribution of this method consisted of developing a descriptor matrix that can be used to represent any EEG file regarding its duration and the number of electrodes. The first study showed that the inter-electrode mean of the spectral power in the gamma frequencies and its duration above a specific threshold performs better than the other frequencies in seizure detection, exhibiting an accuracy of 95.90%, a sensitivity of 92.59%, and a specificity of 96.84%. The second study yielded that Hjorth’s parameter activity is sufficient to accurately relate EEG to epileptic and non-epileptic subjects. After testing, accuracy, sensitivity and specificity of the classifier were all above 0.9667. Statistical tests measured the superiority of activity at over 99.99 % certainty. It was demonstrated that 1) the spectral power in the gamma frequencies is highly effective in locating seizures from EEG and 2) activity can be used to link EEG recordings to epileptic and non-epileptic subjects. These two studies required high computational load and could be addressed thanks to NeuralStudio. From a medical perspective, both methods proved the merits of NeuralStudio in brain research applications. For its outstanding features, NeuralStudio has been recently awarded a patent (US patent No. 7502763)

    Implantable Micro-Device for Epilepsy Seizure Detection and Subsequent Treatment

    Get PDF
    RÉSUMÉ L’émergence des micro-dispositifs implantables est une voie prometteuse pour le traitement de troubles neurologiques. Ces systèmes biomédicaux ont été exploités comme traitements non-conventionnels sur des patients chez qui les remèdes habituels sont inefficaces. Les récents progrès qui ont été faits sur les interfaces neuronales directes ont permis aux chercheurs d’analyser l’activité EEG intracérébrale (icEEG) en temps réel pour des fins de traitements. Cette thèse présente un dispositif implantable à base de microsystèmes pouvant capter efficacement des signaux neuronaux, détecter des crises d’épilepsie et y apporter un traitement afin de l’arrêter. Les contributions principales présentées ici ont été rapportées dans cinq articles scientifiques, publiés ou acceptés pour publication dans les revues IEEE, et plusieurs autres tels que «Low Power Electronics» et «Emerging Technologies in Computing». Le microsystème proposé inclus un circuit intégré (CI) à faible consommation énergétique permettant la détection de crises d’épilepsie en temps réel. Cet CI comporte une pré-amplification initiale et un détecteur de crises d’épilepsie. Le pré-amplificateur est constitué d’une nouvelle topologie de stabilisateur d’hacheur réduisant le bruit et la puissance dissipée. Les CI fabriqués ont été testés sur des enregistrements d’icEEG provenant de sept patients épileptiques réfractaires au traitement antiépileptique. Le délai moyen de la détection d’une crise est de 13,5 secondes, soit avant le début des manifestations cliniques évidentes. La consommation totale d’énergie mesurée de cette puce est de 51 μW. Un neurostimulateur à boucle fermée (NSBF), quant à lui, détecte automatiquement les crises en se basant sur les signaux icEEG captés par des électrodes intracrâniennes et permet une rétroaction par une stimulation électrique au même endroit afin d’interrompre ces crises. La puce de détection de crises et le stimulateur électrique à base sur FPGA ont été assemblés à des électrodes afin de compléter la prothèse proposée. Ce NSBF a été validé en utilisant des enregistrements d’icEEG de dix patients souffrant d’épilepsie réfractaire. Les résultats révèlent une performance excellente pour la détection précoce de crises et pour l’auto-déclenchement subséquent d’une stimulation électrique. La consommation énergétique totale du NSBF est de 16 mW. Une autre alternative à la stimulation électrique est l’injection locale de médicaments, un traitement prometteur de l’épilepsie. Un système local de livraison de médicament basé sur un nouveau détecteur asynchrone des crises est présenté.----------ABSTRACT Emerging implantable microdevices hold great promise for the treatment of patients with neurological conditions. These biomedical systems have been exploited as unconventional treatment for the conventionally untreatable patients. Recent progress in brain-machine-interface activities has led the researchers to analyze the intracerebral EEG (icEEG) recording in real-time and deliver subsequent treatments. We present in this thesis a long-term safe and reliable low-power microsystem-based implantable device to perform efficient neural signal recording, seizure detection and subsequent treatment for epilepsy. The main contributions presented in this thesis are reported in five journal manuscripts, published or accepted for publication in IEEE Journals, and many others such as Low Power Electronics, and Emerging Technologies in Computing. The proposed microsystem includes a low-power integrated circuit (IC) intended for real-time epileptic seizure detection. This IC integrates a front-end preamplifier and epileptic seizure detector. The preamplifier is based on a new chopper stabilizer topology that reduces noise and power dissipation. The fabricated IC was tested using icEEG recordings from seven patients with drug-resistant epilepsy. The average seizure detection delay was 13.5 sec, well before the onset of clinical manifestations. The measured total power consumption of this chip is 51 µW. A closed-loop neurostimulator (CLNS) is next introduced, which is dedicated to automatically detect seizure based on icEEG recordings from intracranial electrode contacts and provide an electrical stimulation feedback to the same contacts in order to disrupt these seizures. The seizure detector chip and a dedicated FPGA-based electrical stimulator were assembled together with common recording electrodes to complete the proposed prosthesis. This CLNS was validated offline using recording from ten patients with refractory epilepsy, and showed excellent performance for early detection of seizures and subsequent self-triggering electrical stimulation. Total power consumption of the CLNS is 16 mW. Alternatively, focal drug injection is the promising treatment for epilepsy. A responsive focal drug delivery system based on a new asynchronous seizure detector is also presented. The later system with data-dependent computation reduces up to 49% power consumption compared to the previous synchronous neurostimulator
    • …
    corecore