14,831 research outputs found
Tevatron Beam Halo Collimation System: Design, Operational Experience and New Methods
Collimation of proton and antiproton beams in the Tevatron collider is
required to protect CDF and D0 detectors and minimize their background rates,
to keep irradiation of superconducting magnets under control, to maintain
long-term operational reliability, and to reduce the impact of beam-induced
radiation on the environment. In this article we briefly describe the design,
practical implementation and performance of the collider collimation system,
methods to control transverse and longitudinal beam halo and two novel
collimation techniques tested in the Tevatron.Comment: 25 p
Luminous red galaxies in the Kilo Degree Survey: selection with broad-band photometry and weak lensing measurements
We use the overlap between multiband photometry of the Kilo-Degree Survey
(KiDS) and spectroscopic data based on the Sloan Digital Sky Survey (SDSS) and
Galaxy And Mass Assembly (GAMA) to infer the colour-magnitude relation of
red-sequence galaxies. We then use this inferred relation to select luminous
red galaxies (LRGs) in the redshift range of over the entire KiDS
Data Release 3 footprint. We construct two samples of galaxies with different
constant comoving densities and different luminosity thresholds. The selected
red galaxies have photometric redshifts with typical photo-z errors of
that are nearly uniform with respect to
observational systematics. This makes them an ideal set of galaxies for lensing
and clustering studies. As an example, we use the KiDS-450 cosmic shear
catalogue to measure the mean tangential shear signal around the selected LRGs.
We detect a significant weak lensing signal for lenses out to
Generation of intense negative ion beams
An electron gun is used with a mirror electrostatic field to produce zero or near zero velocity electrons by forming a turning point in their trajectories. A gas capable of attaching zero or near zero velocity is introduced at this turning point, and negative ions are produced by the attachment or dissociative attachment process. Operation may be continuous or pulsed. Ions thus formed are extracted by a simple lens system and suitable biasing of grids
Double-impulse magnetic focusing of launched cold atoms.
We have theoretically investigated three-dimensional focusing of a launched cloud of cold atoms using a pair of magnetic lens pulses (the alternate-gradient method). Individual lenses focus radially and defocus axially or vice versa. The performance of the two possible pulse sequences are compared and found to be ideal for loading both 'pancake' and 'sausage' shaped magnetic/optical microtraps. It is shown that focusing aberrations are considerably smaller for double-impulse magnetic lenses compared to single-impulse magnetic lenses. An analysis of clouds focused by the double-impulse technique is presented
Getting the most out of a post-column EELS spectrometer on a TEM/STEM by optimising the optical coupling
Ray tracing is used to find improved set-ups of the projector system of a JEOL ARM 200CF TEM/STEM for use in coupling it to a Gatan 965 Quantum ER EELS system and to explain their performance. The system has a probe aberration corrector but no image corrector. With the latter, the problem would be more challenging. The agreement between the calculated performance and that found experimentally is excellent. At 200kV and using the 2.5mm Quantum entrance aperture, the energy range over which the collection angle changes by a maximum of 5% from that at zero loss has been increased from 1.2keV to 4.7keV. At lower accelerating voltages, these energy ranges are lower e.g. at 80kV they are 0.5keV and 2.0keV respectively. The key factors giving the improvement are an increase in the energy-loss at which the projector cross-over goes to infinity and a reduction of the combination aberrations that occur in a lens stack. As well as improving the energy-loss range, the new set-ups reduce spectrum artefacts and minimise the motion of the diffraction pattern at low STEM magnification for electrons that have lost energy. Even if making the pivot points conjugate with the film plane gives no motion for zero-loss electrons, there will be motion for those electrons that have lost energy, leading to a false sense of security when performing spectrum imaging at low magnifications. De-scanning of the probe after the objective lens is a better way of dealing with this problem
Recommended from our members
Widening the scope of virtual reality and augmented reality in dermatology
Virtual reality (VR) and augmented reality (AR) are making headlines, pushing the boundaries of educational experiences and applicability in a variety of fields. Medicine has seen a rapid growth of utilization of these devices for various educational and practical purposes. With respect to the field of dermatology, very few uses are discussed in the literature. We briefly present the current status of VR/AR with regard to this specialty
- …