48,319 research outputs found

    Speech quality monitoring in czech national research network

    Get PDF
    This paper deals with techniques of measuring and assessment of the voice transmitted in IP networks and describes design of quality measurement, which can be used for Cisco Gateways. Cisco gateways send Calculated Planning Impairment Factor in every CDR (Call Detail Record). Our design is based on collection of CDR's, their storing into SQL database and their visualization through web page. This design was implemented and successfully tested in CESNET network.8511711

    Augmented Reality-based Feedback for Technician-in-the-loop C-arm Repositioning

    Full text link
    Interventional C-arm imaging is crucial to percutaneous orthopedic procedures as it enables the surgeon to monitor the progress of surgery on the anatomy level. Minimally invasive interventions require repeated acquisition of X-ray images from different anatomical views to verify tool placement. Achieving and reproducing these views often comes at the cost of increased surgical time and radiation dose to both patient and staff. This work proposes a marker-free "technician-in-the-loop" Augmented Reality (AR) solution for C-arm repositioning. The X-ray technician operating the C-arm interventionally is equipped with a head-mounted display capable of recording desired C-arm poses in 3D via an integrated infrared sensor. For C-arm repositioning to a particular target view, the recorded C-arm pose is restored as a virtual object and visualized in an AR environment, serving as a perceptual reference for the technician. We conduct experiments in a setting simulating orthopedic trauma surgery. Our proof-of-principle findings indicate that the proposed system can decrease the 2.76 X-ray images required per desired view down to zero, suggesting substantial reductions of radiation dose during C-arm repositioning. The proposed AR solution is a first step towards facilitating communication between the surgeon and the surgical staff, improving the quality of surgical image acquisition, and enabling context-aware guidance for surgery rooms of the future. The concept of technician-in-the-loop design will become relevant to various interventions considering the expected advancements of sensing and wearable computing in the near future

    Self-imitating Feedback Generation Using GAN for Computer-Assisted Pronunciation Training

    Full text link
    Self-imitating feedback is an effective and learner-friendly method for non-native learners in Computer-Assisted Pronunciation Training. Acoustic characteristics in native utterances are extracted and transplanted onto learner's own speech input, and given back to the learner as a corrective feedback. Previous works focused on speech conversion using prosodic transplantation techniques based on PSOLA algorithm. Motivated by the visual differences found in spectrograms of native and non-native speeches, we investigated applying GAN to generate self-imitating feedback by utilizing generator's ability through adversarial training. Because this mapping is highly under-constrained, we also adopt cycle consistency loss to encourage the output to preserve the global structure, which is shared by native and non-native utterances. Trained on 97,200 spectrogram images of short utterances produced by native and non-native speakers of Korean, the generator is able to successfully transform the non-native spectrogram input to a spectrogram with properties of self-imitating feedback. Furthermore, the transformed spectrogram shows segmental corrections that cannot be obtained by prosodic transplantation. Perceptual test comparing the self-imitating and correcting abilities of our method with the baseline PSOLA method shows that the generative approach with cycle consistency loss is promising

    Feasibility of intensity-modulated and image-guided radiotherapy for functional organ preservation in locally advanced laryngeal cancer

    Get PDF
    Purpose: The study aims to assess the feasibility of intensity-modulated and image-guided radiotherapy (IMRT, and IGRT, respectively) for functional preservation in locally advanced laryngeal cancer. A retrospective review of 27 patients undergoing concurrent chemoradiation for locally advanced laryngeal cancers (8 IMRT, 19 IGRT) was undertaken. In addition to regular clinical examinations, all patients had PET imaging at 4 months and 10 months after radiotherapy, then yearly. Loco-regional control, speech quality and feeding-tube dependency were assessed during follow-up visits. Results: At a median follow-up of 20 months (range 6-57 months), four out of 27 patients (14.8%) developed local recurrence and underwent salvage total laryngectomy. One patient developed distant metastases following salvage surgery. Among the 23 patients who conserved their larynx with no sign of recurrence at last follow-up, 22 (95%) reported normal or near normal voice quality, allowing them to communicate adequately. Four patients (14.8%) had long-term tube feeding-dependency because of severe dysphagia (2 patients) and chronic aspiration (2 patients, with ensuing death from aspiration pneumonia in one patient). Conclusions and Clinical Relevance: Functional laryngeal preservation is feasible with IMRT and IGRT for locally advanced laryngeal cancer. However, dysphagia and aspiration remain serious complications, due most likely to high radiation dose delivery to the pharyngeal musculatures. © 2012 Nguyen et al
    corecore