18,404 research outputs found

    Solving the tasks of subsurface resources management in GIS RAPID environment

    Get PDF
    Purpose. Solving the tasks of subsurface resources management based on the created GIS RAPID geoinformation technology. Methods. Close spatial relationships of lineament network characteristics and earthquake epicenters were detected in 3 seismically active areas located in the mountainous regions of Central Europe. Digital elevation models (DEM) based on ASTER satellite surveys and earthquake epicenter data were used. The nature of spatial relationship of lineament network and vein ore objects was studied in the territory of Congo DR, in the Lake Kivu area using space imagery. Gold ore objects were searched and forecasted in Uzbekistan in the site of Jamansai Mountains. High- resolution imagery from QuickBird 2 satellite, geophysical field surveys, geological and geochemical data were used. Findings. It was found that a significant number of epicenters are located in areas of high concentration of “non-standard” azimuths lineaments – from 27 to 34% of the total number of lineaments. It was revealed that 59.6% of the epicenters are located within 10% of sites with the highest values of complex deformation maps; 50% of the areas with the highest values of these maps contain, on average, 89% of all earthquake epicenters. It was found that satellite image lineament concentration maps with “non-standard” azimuths reflect the spatial relationship with known deposits much better than the concentration map of all lineaments. It was detected that the total area of gold ore objects perspective sites is about 20 km2. Originality. The use of GIS RAPID in a number of earth’s crust areas has allowed to establish new regularities linking the networks of physical field and landscape lineament characteristics with ore bodies and earthquake epicenters localization. Practical implications. A new technology has been developed for solving geological forecasting and prospecting problems. The technology can be used to solve a wide range of practical problems, especially in difficult geological conditions when searching for deep objects weakly presented in external fields and landscape.Мета. Рішення задач надрокористування на базі створеної геоінформаційної технології ГІС РАПІД. Методика. Виявлення тісних просторових взаємозв’язків різноманітних характеристик мереж лінеаментів і епіцентрів землетрусів проводилося у 3 сейсмоактивних ділянках, розташованих в гірських районах Центральної Європи. Використовувалися цифрові моделі рельєфу (DEM), побудовані за зйомками зі супутника ASTER і дані по епіцентрах землетрусів. Дослідження характеру просторового взаємозв’язку мережі лінеаментів і жильних рудних об’єктів проводилися на території Демократичної Республіки Конго, в районі озера Ківу із використанням космічних зйомок. Дослідження пошуку та прогнозу золоторудних об’єктів виконувалися в Узбекистані на ділянці Джамансайскіх гір. Використовувалися високоточні космічні зйомки зі супутника QuickBird 2, зйомки геофізичних полів, геологічні та геохімічні дані. Результати. Виявлено, що значна частина епіцентрів приурочена саме до ділянок підвищеної концентрації лінеаментів “нестандартних” азимутів, складаючи від 27 до 34% загального числа лінеаментів. Встановлено, що 59.6% епіцентрів знаходяться всередині 10% території ділянок, що володіють найвищими значеннями комплексних карт деформацій; 50% території з найвищими значеннями цих карт вміщають, в середньому, 89% усіх епіцентрів землетрусів. Визначено, що карти концентрації лінеаментів космознімків з “нестанартними” азимутами значно краще відображають просторовий взаємозв’язок з відомими родовищами у порівнянні з картою концентрації всіх лінеаментів. Встановлено, що сумарна площа перспективних ділянок золоторудних об’єктів склала близько 20 км2. Наукова новизна. Застосування ГІС РАПІД на ряді ділянок земної кори дозволило встановити нові закономірності, що зв’язують характеристики мережі лінеаментів фізичних полів і ландшафту з локалізацією рудних тіл та епіцентрів землетрусів. Практична значимість. Розроблено нову технологію рішення прогнозних і пошукових геологічних завдань, яка може застосовуватися для вирішення широкого кола практичних задач, особливо у складних геологічних умовах при пошуках глибокозалягаючих об’єктів, що слабо виявляються в зовнішніх полях і ландшафті.Цель. Решения задач недропользования на базе созданной геоинформационной технологии ГИС РАПИД. Методика. Выявление тесных пространственных взаимосвязей разнообразных характеристик сетей линеаментов и эпицентров землетрясений проводилось в 3 сейсмоактивных участках, расположенных в горных районах Центральной Европы. Использовались цифровые модели рельефа (DEM), построенные по съемкам со спутника ASTER, и данные об эпицентрах землетрясений. Исследования характера пространственной взаимосвязи сети линеаментов и жильных рудных объектов проводились на территории Демократической Республики Конго, в районе озера Киву с использованием космических съемок. Исследования поиска и прогноза золоторудных объектов выполнялись в Узбекистане на участке Джамансайских гор. Использовались высокоточные космические съемки со спутника QuickBird 2, съемки геофизических полей, геологические и геохимические данные. Результаты. Выявлено, что значительная часть эпицентров приурочена именно к участкам повышенной концентрации линеаментов “нестандартных” азимутов, составляя от 27 до 34% общего числа линеаментов. Установлено, что 59.6% эпицентров находятся внутри 10% территории участков, обладающих наивысшими значениями комплексных карт деформаций; 50% территории с наивысшими значениями этих карт вмещают, в среднем, 89% всех эпицентров землетрясений. Определено, что карты концентрации линеаментов космоснимков с “нестанартными” азимутами значительно лучше отражают пространственную взаимосвязь с известными месторождениями по сравнению с картой концентрации всех линеаментов. Установлено, что суммарная площадь перспективных участков золоторудных объектов составила около 20 км2. Научная новизна. Применение ГИС РАПИД на ряде участков земной коры позволило установить новые закономерности, связывающие характеристики сети линеаментов физических полей и ландшафта с локализацией рудных тел и эпицентров землетрясений. Практическая значимость. Разработана новая технология решения прогнозных и поисковых геологических задач, которая может применяться для решения широкого круга практических задач, особенно в сложных геологических условиях при поисках глубокозалегающих объектов, слабо проявляющихся во внешних полях и ландшафте.The work is performed as a part of planned research of the geoinformation systems department of the Dnipro University of Technology. The results are obtained without any financial support of grants and research projects. The authors express appreciation to reviewers and editors for their valuable comments, recommendations, and attention to the work

    Display elements and gaps: a comparison of flat panel display characteristics

    Get PDF
    The relation between typical flat panel display characteristics and display quality was studied. Subjective preferences were obtained with respect to simulated black-on-white flat panel displays. The displays differed in the sort of separation between the display elements and the shape of these elements. Further, the height/width ratio of the front was studied in relation with a fixed font matrix. The preferences were obtained through a paired comparison of all possible pairs of simulated displays.\ud \ud The observers appeared to be sensitive and to respond to differences in the stimuli. It is not clear, however, if they responded to the type of gap and shape of display elements or to the luminance modulation, which co-varied with the two experimental factors. It can be concluded however that the integrity of the character area is important to the observers. Further, the usefulness of interactively designing spatial display characteristics and the font is discussed

    Optical coherence tomography fast versus regular macular thickness mapping in diabetic retinopathy

    Get PDF
    Objective: The purpose of the study was to investigate if absolute values and reproducibility of thickness maps obtained from 2 optical coherence tomography (OCT) scanning protocols, regular high-resolution and fast low-density mode, differ in patients with diabetic macular edema. Methods: A total of 26 consecutive patients undergoing fluorescein angiography and Stratus OCT scanning for the evaluation of diabetic macular edema at the Departments of Ophthalmology in Munich and Vienna were included. Results: Retinal thickness of the central field of the thickness map measured by fast retinal thickness protocol was 287 +/- 97 and 290 +/- 113 mu m by the regular protocol. This difference as well as that for all other fields was not statistically significant. Three times repeated measurements applying both OCT scanning modes in 10 patients yielded very good intrasession correlation coefficients between 0.70 and 0.99, with corresponding intrasession standard deviations ranging between 6 and 16 mu m. The fast mode yielded slightly less reproducible values than the regular mode. Visual acuity did not influence the results. Conclusion: In practice both scanning modes caninterchanged and absolute values can be compared directly. Best reproducibility is obtained with higher sampling density even in patients with reduced visual acuity due to diabetic macular edema. Copyright (C) 2008 S. Karger AG, Basel

    Fluorescein angiography compared to three-dimensional measurements by the retinal thickness analyzer in classic choroidal neovascularization

    Get PDF
    Purpose: To compare and correlate imaging of classic subfoveal choroidal neovascularization (CNV) with noninvasive 3-dimensional imaging by the retinal thickness analyzer (RTA) to conventional fluorescein angiography (FA). Methods: A total of 29 eyes of 29 consecutive patients with predominantly classic CNV eligible for photodynamic therapy underwent FA and RTA imaging. The FA dimensions of the CNV were measured independently by two graders. With the RTA, masked to FA the size of the CNV itself as imaged in 3-dimensional reconstruction, the size of significantly thickened retina overlying the CNV and the maximum retinal thickness were measured. Results: The mean diameter of the CNV determined from 3-dimensional RTA reconstructions showed an excellent correlation with measurements from FA (r = 0.91, p < 0.001). The area of retinal thickening was by a mean of 0.7 mm in diameter larger and correlated moderately well with the size of the CNV on FA (r = 0.65, p < 0.001). In contrast, there was no correlation between the absolute retinal thickness and the CNV size on FA. Conclusions: Noninvasive quantitative mapping of predominantly classic CNV by RTA is feasible and also allows 3-dimensional measurement of the lesion itself. The results correlate well with FA assessment but visualize different properties of the disease. Copyright (c) 2007 S. Karger AG, Basel

    Requirements for Provenance on the Web

    Get PDF
    From where did this tweet originate? Was this quote from the New York Times modified? Daily, we rely on data from the Web but often it is difficult or impossible to determine where it came from or how it was produced. This lack of provenance is particularly evident when people and systems deal with Web information or with any environment where information comes from sources of varying quality. Provenance is not captured pervasively in information systems. There are major technical, social, and economic impediments that stand in the way of using provenance effectively. This paper synthesizes requirements for provenance on the Web for a number of dimensions focusing on three key aspects of provenance: the content of provenance, the management of provenance records, and the uses of provenance information. To illustrate these requirements, we use three synthesized scenarios that encompass provenance problems faced by Web users toda

    Globalization or Localization? A longitudinal study of successful American and Chinese online store websites

    Get PDF
    This paper reports the results of a longitudinal study of 2562 images on the homepages of successful American and Chinese online store websites,with the goal of determining whether cultural factors impact their visual presentation and evolution. Descriptive and statistical content analyses reveal that the U.S. and Chinese online store sites showed significant cross-national image differences from their inception; moreover, the Chinese sites diverged further from the U.S. sites over time, strengthening their own cultural identity and suggesting a trend towards localization in a diverse and dynamic world market. These findings support the view that although English-speaking Western culture is widespread in today’s Information Age, other cultures are not necessarily undermined
    corecore