1,888 research outputs found
Wireless communication, identification and sensing technologies enabling integrated logistics: a study in the harbor environment
In the last decade, integrated logistics has become an important challenge in
the development of wireless communication, identification and sensing
technology, due to the growing complexity of logistics processes and the
increasing demand for adapting systems to new requirements. The advancement of
wireless technology provides a wide range of options for the maritime container
terminals. Electronic devices employed in container terminals reduce the manual
effort, facilitating timely information flow and enhancing control and quality
of service and decision made. In this paper, we examine the technology that can
be used to support integration in harbor's logistics. In the literature, most
systems have been developed to address specific needs of particular harbors,
but a systematic study is missing. The purpose is to provide an overview to the
reader about which technology of integrated logistics can be implemented and
what remains to be addressed in the future
Open-Source Telemedicine Platform for Wireless Medical Video Communication
An m-health system for real-time wireless communication of medical video based on open-source software is presented. The objective is to deliver a low-cost telemedicine platform which will allow for reliable remote diagnosis m-health applications such as emergency incidents, mass population screening, and medical education purposes. The performance of the proposed system is demonstrated using five atherosclerotic plaque ultrasound videos. The videos are encoded at the clinically acquired resolution, in addition to lower, QCIF, and CIF resolutions, at different bitrates, and four different encoding structures. Commercially available wireless local area network (WLAN) and 3.5G high-speed packet access (HSPA) wireless channels are used to validate the developed platform. Objective video quality assessment is based on PSNR ratings, following calibration using the variable frame delay (VFD) algorithm that removes temporal mismatch between original and received videos. Clinical evaluation is based on atherosclerotic plaque ultrasound video assessment protocol. Experimental results show that adequate diagnostic quality wireless medical video communications are realized using the designed telemedicine platform. HSPA cellular networks provide for ultrasound video transmission at the acquired resolution, while VFD algorithm utilization bridges objective and subjective ratings
A Priority-based Fair Queuing (PFQ) Model for Wireless Healthcare System
Healthcare is a very active research area, primarily due to the increase in the elderly population that leads to increasing number of emergency situations that require urgent actions. In recent years some of wireless networked medical devices were equipped with different sensors to measure and report on vital signs of patient remotely. The most important sensors are Heart Beat Rate (ECG), Pressure and Glucose sensors. However, the strict requirements and real-time nature of medical applications dictate the extreme importance and need for appropriate Quality of Service (QoS), fast and accurate delivery of a patientâs measurements in reliable e-Health ecosystem.
As the elderly age and older adult population is increasing (65 years and above) due to the advancement in medicine and medical care in the last two decades; high QoS and reliable e-health ecosystem has become a major challenge in Healthcare especially for patients who require continuous monitoring and attention. Nevertheless, predictions have indicated that elderly population will be approximately 2 billion in developing countries by 2050 where availability of medical staff shall be unable to cope with this growth and emergency cases that need immediate intervention. On the other side, limitations in communication networks capacity, congestions and the humongous increase of devices, applications and IOT using the available communication networks add extra layer of challenges on E-health ecosystem such as time constraints, quality of measurements and signals reaching healthcare centres.
Hence this research has tackled the delay and jitter parameters in E-health M2M wireless communication and succeeded in reducing them in comparison to current available models. The novelty of this research has succeeded in developing a new Priority Queuing model ââPriority Based-Fair Queuingââ (PFQ) where a new priority level and concept of ââPatientâs Health Recordââ (PHR) has been developed and
integrated with the Priority Parameters (PP) values of each sensor to add a second level of priority. The results and data analysis performed on the PFQ model under different scenarios simulating real M2M E-health environment have revealed that the PFQ has outperformed the results obtained from simulating the widely used current models such as First in First Out (FIFO) and Weight Fair Queuing (WFQ).
PFQ model has improved transmission of ECG sensor data by decreasing delay and jitter in emergency cases by 83.32% and 75.88% respectively in comparison to FIFO and 46.65% and 60.13% with respect to WFQ model. Similarly, in pressure sensor the improvements were 82.41% and 71.5% and 68.43% and 73.36% in comparison to FIFO and WFQ respectively. Data transmission were also improved in the Glucose sensor by 80.85% and 64.7% and 92.1% and 83.17% in comparison to FIFO and WFQ respectively. However, non-emergency cases data transmission using PFQ model was negatively impacted and scored higher rates than FIFO and WFQ since PFQ tends to give higher priority to emergency cases.
Thus, a derivative from the PFQ model has been developed to create a new version namely âPriority Based-Fair Queuing-Tolerated Delayâ (PFQ-TD) to balance the data transmission between emergency and non-emergency cases where tolerated delay in emergency cases has been considered. PFQ-TD has succeeded in balancing fairly this issue and reducing the total average delay and jitter of emergency and non-emergency cases in all sensors and keep them within the acceptable allowable standards. PFQ-TD has improved the overall average delay and jitter in emergency and non-emergency cases among all sensors by 41% and 84% respectively in comparison to PFQ model
Flexible Macroblock Ordering for Context-Aware Ultrasound Video Transmission over Mobile WiMAX
The most recent network technologies are enabling
a variety of new applications, thanks to the provision of increased bandwidth and better management of Quality of Service.
Nevertheless, telemedical services involving multimedia data are still lagging behind, due to the concern of the end users, that is,
clinicians and also patients, about the low quality provided. Indeed, emerging network technologies should be appropriately
exploited by designing the transmission strategy focusing on quality provision for end users. Stemming from this principle, we
propose here a context-aware transmission strategy for medical video transmission over WiMAX systems. Context, in terms of
regions of interest (ROI) in a specific session, is taken into account for the identification of multiple regions of interest,
and compression/transmission strategies are tailored to such context information. We present a methodology based on H.264
medical video compression and Flexible Macroblock Ordering (FMO) for ROI identification. Two different unequal error
protection methodologies, providing higher protection to the most diagnostically relevant data, are presented
A Review on Provisioning Quality of Service of Wireless Telemedicine for E-Health Services
In general, on-line medical consultation reduces time required for medical consultation induces
improvement in the quality and efficiency of healthcare services. All major types of current e-health applications such as ECG, X-ray, video, diagnosis images and other common applications have been included in the scope of the study. In addition, the provision of Quality of Service (QoS) for the application of specific healthcare services in e-health, the scheme of priority for e-health services and the support of QoS in wireless networks and techniques or methods for IEEE 802.11 to guarantee the provision of QoS has also been assessed.
In e-health, medical services in remote locations such as rural healthcare centers, ambulances, ships as well as
home healthcare services can be supported through the applications of e-health services such as medical
databases, electronic health records and the routing of text, audio, video and images. Given this, an adaptive
resource allocation for a wireless network with multiple service types and multiple priorities have been
proposed. For the provision of an acceptable QoS level to users of e-health services, prioritization is an
important criterion in a multi-traffic network. The requirement for QoS provisioning in wireless broadband
medical networks have paved the pathway for bandwidth requirements and the real-time or live transmission
of medical applications. From the study, good performance of the proposed scheme has been validated by the
results obtained. The proposed wireless network is capable of handling medical applications for both normal
and life-threatening conditions as characterized by the level of emergencies. In addition, the bandwidth
allocation and admission control algorithm for IEEE 802.16- based design specifically for wireless
telemedicine/e-health services have also been presented in the study. It has been concluded that under busy
traffic conditions, the proposed architecture can used as a feasible and reliable infrastructure network for
telemedicine
Recommended from our members
Application priority framework for fixed mobile converged communication networks
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.The current prospects in wired and wireless access networks, it is becoming increasingly important to address potential convergence in order to offer integrated broadband services. These systems will need to offer higher data transmission capacities and long battery life, which is the catalyst for an everincreasing variety of air interface technologies targeting local area to wide area connectivity. Current integrated industrial networks do not offer application aware context delivery and enhanced services for optimised networks. Application aware services provide value-added functionality to business applications by capturing, integrating, and consolidating intelligence about users and their endpoint devices from various points in the network. This thesis mainly intends to resolve the issues related to ubiquitous application aware service, fair allocation of radio access, reduced energy consumption and improved capacity. A technique that measures and evaluates the data rate demand to reduce application response time and queuing delay for multi radio interfaces is proposed. The technique overcomes the challenges of network integration, requiring no user intervention, saving battery life and selecting the radio access connection for the application requested by the end user. This study is split in two parts. The first contribution identifies some constraints of the services towards the application layer in terms of e.g. data rate and signal strength. The objectives are achieved by application controlled handover (ACH) mechanism in order to maintain acceptable data rate for real-time application services. It also looks into the impact of the radio link on the application and identifies elements and parameters like wireless link quality and handover that will influence the application type. It also identifies some enhanced traditional mechanisms such as distance controlled multihop and mesh topology required in order to support energy efficient multimedia applications. The second contribution unfolds an intelligent application priority assignment mechanism (IAPAM) for medical applications using wireless sensor networks. IAPAM proposes and evaluates a technique based on prioritising multiple virtual queues for the critical nature of medical data to improve instant transmission. Various mobility patterns (directed, controlled and random waypoint) has been investigated and compared by simulating IAPAM enabled mobile BWSN. The following topics have been studied, modelled, simulated and discussed in this thesis: 1. Application Controlled Handover (ACH) for multi radios over fibre 2. Power Controlled Scheme for mesh multi radios over fibre using ACH 3. IAPAM for Biomedical Wireless Sensor Networks (BWSN) and impact of mobility over IAPAM enabled BWSN. Extensive simulation studies are performed to analyze and to evaluate the proposed techniques. Simulation results demonstrate significant improvements in multi radios over fibre performance in terms of application response delay and power consumption by upto 75% and 15 % respectively, reduction in traffic loss by upto 53% and reduction in delay for real time application by more than 25% in some cases
- âŚ