55 research outputs found

    Inverse kinematics solution for trajectory tracking using artificial neural networks for SCORBOT ER-4u

    Get PDF
    This paper presents the kinematic analysis of the SCORBOT-ER 4u robot arm using a Multi-Layered Feed-Forward (MLFF) Neural Network. The SCORBOT-ER 4u is a 5-DOF vertical articulated educational robot with revolute joints. The Denavit-Hartenberg and Geometrical methods are the forward kinematic algorithms used to generate data and train the neural network. The learning of forward-inverse mapping enables the inverse kinematic solution to be found. The algorithm is tested on hardware (SCORBOT-ER 4u) and reliable results are obtained. The modeling and simulations are done using MATLAB 8.0 software

    The design of a control architecture for a heavy-lift precision manipulator for use in contact with the environment

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006."June 2006."Includes bibliographical references (leaves 117-121).Robotic manipulators can be used to enhance the strength and dexterity of a human user. This thesis considers the design of a controller for a heavy-lift manipulator for lifting and inserting payloads onto aircraft on the deck of a ship. The purpose of this robot is to reduce manpower requirements aboard the ship, and reduce the physical requirements for the individuals loading the payloads onto an aircraft. This particular application presents several control challenges, including structural resonances, complex interaction with the environment, high joint friction that varies over time, tight tolerances for the insertion tasks, and ship motions. This thesis builds upon previous works by Garretson [17] and DiCicco [9] by further developing an insertion control mode for intuitive human interaction with the payload of the manipulator when in contact with the environment. These control algorithms, as well as those developed in the previous work, are also validated on a laboratory manipulator. This thesis contains a detailed description of the control architecture for the heavy lift manipulator, including the insertion control mode and a position control mode for use when the manipulator is not in contact with the environment. Both architectures are validated with dynamic simulation models.(cont.) The position control response of this manipulator is shown to be improved with the implementation of friction compensation. In some joints, outputs from an adaptive friction estimator are used to make feed-forward models of friction for use during environmental contact. The position and insertion controllers are then evaluated under open-loop and human control on a laboratory manipulator.by William T. Becker, III.S.M

    On the Application of Mechanical Vibration in Robotics-Assisted Soft Tissue Intervention

    Get PDF
    Mechanical vibration as a way of transmitting energy has been an interesting subject to study. While cyclic oscillation is usually associated with fatigue effect, and hence a detrimental factor in failure of structures and machineries, by controlled transmission of vibration, energy can be transferred from the source to the target. In this thesis, the application of such mechanical vibration in a few surgical procedures is demonstrated. Three challenges associated with lung cancer diagnosis and treatment are chosen for this purpose, namely, Motion Compensation, tumor targeting in lung Needle Insertion and Soft Tissue Dissection: A robotic solution is proposed for compensating for the undesirable oscillatory motion of soft tissue (caused by heart beat and respiration) during needle insertion in the lung. An impedance control strategy based on a mechanical vibratory system is implemented to minimize the tissue deformation during needle insertion. A prototype was built to evaluate the proposed approach using: 1) two Mitsubishi PA10-7C robots, one for manipulating the macro part and the other for mimicking the tissue motion, 2) one motorized linear stage to handle the micro part, and 3) a Phantom Omni haptic device for remote manipulation. Experimental results are given to demonstrate the performance of the motion compensation system. A vibration-assisted needle insertion technique has been proposed in order to reduce needle–tissue friction. The LuGre friction model is employed as a basis for the study and the model is extended and analyzed to include the impact of high-frequency vibration on translational friction. Experiments are conducted to evaluate the role of insertion speed as well as vibration frequency on frictional effects. In the experiments conducted, an 18 GA brachytherapy needle was vibrated and inserted into an ex-vivo soft tissue sample using a pair of amplified piezoelectric actuators. Analysis demonstrates that the translational friction can be reduced by introducing a vibratory low-amplitude motion onto a regular insertion profile, which is usually performed at a constant rate. A robotics-assisted articulating ultrasonic surgical scalpel for minimally invasive soft tissue cutting and coagulation is designed and developed. For this purpose, the optimal design of a Langevin transducer with stepped horn profile is presented for internal-body applications. The modeling, optimization and design of the ultrasonic scalpel are performed through equivalent circuit theory and verified by finite element analysis. Moreover, a novel surgical wrist, compatible with the da Vinci® surgical system, with decoupled two degrees-of-freedom (DOFs) is developed that eliminates the strain of pulling cables and electrical wires. The developed instrument is then driven using the dVRK (da Vinci® research kit) and the Classic da Vinci® surgical system

    A minimally invasive surgical system for 3D ultrasound guided robotic retrieval of foreign bodies from a beating heart

    Get PDF
    The result of various medical conditions and trauma, foreign bodies in the heart pose a serious health risk as they may interfere with cardiovascular function. Particles such as thrombi, bullet fragments, and shrapnel can become trapped in a person's heart after migrating through the venous system, or by direct penetration. The severity of disruption can range from benign to fatal, with associated symptoms including anxiety, fever, cardiac tamponade, hemorrhage, infection, embolism, arrhythmia, and valve dysfunction. Injuries of this nature are common in both civilian and military populations. For symptomatic cases, conventional treatment is removal of the foreign body through open surgery via a median sternotomy, the use of cardiopulmonary bypass, and a wide incision in the heart muscle; these methods incur pronounced perioperative risks and long recovery periods. In order to improve upon the standard of care, we propose an image guided robotic system and a corresponding minimally invasive surgical approach. The system employs a dexterous robotic capture device that can maneuver inside the heart through a small incision. Visualization and guidance within the otherwise occluded internal regions are provided by 3D transesophageal echocardiography (TEE), an emerging form of intraoperative medical imaging used in interventions such as mitral valve repair and device implantation. A robotic approach, as opposed to a manual procedure using rigid instruments, is motivated by the various challenges inherent in minimally invasive surgery, which arise from attempts to perform skilled surgical tasks through small incisions without direct vision. Challenges include reduced dexterity, constrained workspace, limited visualization, and difficult hand-eye coordination, which ultimately lead to poor manipulability. A dexterous robotic end effector with real-time image guidance can help overcome these challenges and potentially improve surgical performance. However promising, such a system and approach require that several technical hurdles be resolved. The foreign body must be automatically tracked as it travels about the dynamic environment of the heart. The erratically moving particle must then be captured using a dexterous robot that moves much more slowly in comparison. Furthermore, retrieval must be performed under 3D ultrasound guidance, amidst the uncertainties presented by both the turbulent flow and by the imaging modality itself. In addressing such barriers, this thesis explores the development of a prototype system capable of retrieving a foreign body from a beating heart, culminating in a set of demonstrative in vitro experiments
    corecore