660 research outputs found

    Inside the brain of an elite athlete: The neural processes that support high achievement in sports

    Get PDF
    Events like the World Championships in athletics and the Olympic Games raise the public profile of competitive sports. They may also leave us wondering what sets the competitors in these events apart from those of us who simply watch. Here we attempt to link neural and cognitive processes that have been found to be important for elite performance with computational and physiological theories inspired by much simpler laboratory tasks. In this way we hope to inspire neuroscientists to consider how their basic research might help to explain sporting skill at the highest levels of performance

    MOTOR EVOKED POTENTIALS AND TRANSCUTANEOUS MAGNETO-ELECTRICAL NERVE STIMULATION

    Get PDF
    The purpose of this study was to identify the mechanism of cerebral cortex human isometric contraction information processing. By using transcutaneous magneto-electrical nerve stimulation technique, musculi flexor crapi radialis/ulnaris isometric contracts, the nerve digitals palmares/volares communes nerve mediani/ulnaris were stimulated. The results showed that many evoked potential amplitude of gyrus postcentralis and praecentralis, lobules parietals superior and inferior, gyrus temporaries’ superior/medius/inferior are significantly different to each other. Some peak absolute latency and interpeak /interwave latency, either sensory or motor was shorter in the same side hemisphere, while those in the opposing side hemisphere were longer. The above results indicated that the sensory afferent information occurred previously in the same side hemisphere rather than the opposing hemisphere

    Disruption of Saccadic Adaptation with Repetitive Transcranial Magnetic Stimulation of the Posterior Cerebellum in Humans

    Get PDF
    Saccadic eye movements are driven by motor commands that are continuously modified so that errors created by eye muscle fatigue, injury, or—in humans—wearing spectacles can be corrected. It is possible to rapidly adapt saccades in the laboratory by introducing a discrepancy between the intended and actual saccadic target. Neurophysiological and lesion studies in the non-human primate as well as neuroimaging and patient studies in humans have demonstrated that the oculomotor vermis (lobules VI and VII of the posterior cerebellum) is critical for saccadic adaptation. We studied the effect of transiently disrupting the function of posterior cerebellum with repetitive transcranial magnetic stimulation (rTMS) on the ability of healthy human subjects to adapt saccadic eye movements. rTMS significantly impaired the adaptation of the amplitude of saccades, without modulating saccadic amplitude or variability in baseline conditions. Moreover, increasing the intensity of rTMS produced a larger impairment in the ability to adapt saccadic size. These results provide direct evidence for the role of the posterior cerebellum in man and further evidence that TMS can modulate cerebellar function

    Eccentric Figure-Eight Coils for Transcranial Magnetic Stimulation

    Get PDF
    Previously we proposed an eccentric figure-eight coil that can cause threshold stimulation in the brain at lower driving currents. In this study, we performed numerical simulations and magnetic stimulations to healthy subjects for evaluating the advantages of the eccentric coil. The simulations were performed using a simplified spherical brain model and a realistic human brain model. We found that the eccentric coil required a driving current intensity of approximately 18% less than that required by the concentric coil to cause comparable eddy current densities within the brain. The eddy current localization of the eccentric coil was slightly higher than that of the concentric coil. A prototype eccentric coil was designed and fabricated. Instead of winding a wire around a bobbin, we cut eccentric-spiral slits on the insulator cases, and a wire was woven through the slits. The coils were used to deliver magnetic stimulation to healthy subjects; among our results, we found that the current slew rate corresponding to motor threshold values for the concentric and eccentric coils were 86 and 78 A/µs, respectively. The results indicate that the eccentric coil consistently requires a lower driving current to reach the motor threshold than the concentric coil. Future development of compact magnetic stimulators will enable the treatment of some intractable neurological diseases at home. Bioelectromagnetics. 35:55–65, 2015. © 2014 Wiley Periodicals, Inc.ArticleBIOELECTROMAGNETICS. 36(1):55-65 (2015)journal articl

    Reversal of TMS-induced motor twitch by training is associated with a reduction in excitability of the antagonist muscle

    Get PDF
    Background: A single session of isolated repetitive movements of the thumb can alter the response to transcranial magnetic stimulation (TMS), such that the related muscle twitch measured post-training occurs in the trained direction. This response is attributed to transient excitability changes in primary motor cortex (M1) that form the early part of learning. We investigated; (1) whether this phenomenon might occur for movements at the wrist, and (2) how specific TMS activation patterns of opposing muscles underlie the practice-induced change in direction. Methods: We used single-pulse suprathreshold TMS over the M1 forearm area, to evoke wrist movements in 20 healthy subjects. We measured the preferential direction of the TMS-induced twitch in both the sagittal and coronal plane using an optical goniometer fixed to the dorsum of the wrist, and recorded electromyographic (EMG) activity from the flexor carpi radialis (FCR) and extensor carpi radialis (ECR) muscles. Subjects performed gentle voluntary movements, in the direction opposite to the initial twitch for 5 minutes at 0.2 Hz. We collected motor evoked potentials (MEPs) elicited by TMS at baseline and for 10 minutes after training. Results: Repetitive motor training was sufficient for TMS to evoke movements in the practiced direction opposite to the original twitch. For most subjects the effect of the newly-acquired direction was retained for at least 10 minutes before reverting to the original. Importantly, the direction change of the movement was associated with a significant decrease in MEP amplitude of the antagonist to the trained muscle, rather than an increase in MEP amplitude of the trained muscle. Conclusions: These results demonstrate for the first time that a TMS-twitch direction change following a simple practice paradigm may result from reduced corticospinal drive to muscles antagonizing the trained direction. Such findings may have implications for training paradigms in neurorehabilitation

    Differential activation of nerve fibers with magnetic stimulation in humans

    Get PDF
    BACKGROUND: Earlier observations in our lab had indicated that large, time-varying magnetic fields could elicit action potentials that travel in only one direction in at least some of the myelinated axons in peripheral nerves. The objective of this study was to collect quantitative evidence for magnetically induced unidirectional action potentials in peripheral nerves of human subjects. A magnetic coil was maneuvered to a location on the upper arm where physical effects consistent with the creation of unidirectional action potentials were observed. Electromyographic (EMG) and somatosensory evoked potential (SEP) recordings were then made from a total of 20 subjects during stimulation with the magnetic coil. RESULTS: The relative amplitudes of the EMG and SEP signals changed oppositely when the current direction in the magnetic coil was reversed. This effect was consistent with current direction in the coil relative to the arm for all subjects. CONCLUSION: A differential evocation of motor and sensory fibers was demonstrated and indicates that it may be possible to induce unidirectional action potentials in myelinated peripheral nerve fibers with magnetic stimulation

    Encoding cortical dynamics in sparse features.

    Get PDF
    Distributed cortical solutions of magnetoencephalography (MEG) and electroencephalography (EEG) exhibit complex spatial and temporal dynamics. The extraction of patterns of interest and dynamic features from these cortical signals has so far relied on the expertise of investigators. There is a definite need in both clinical and neuroscience research for a method that will extract critical features from high-dimensional neuroimaging data in an automatic fashion. We have previously demonstrated the use of optical flow techniques for evaluating the kinematic properties of motion field projected on non-flat manifolds like in a cortical surface. We have further extended this framework to automatically detect features in the optical flow vector field by using the modified and extended 2-Riemannian Helmholtz-Hodge decomposition (HHD). Here, we applied these mathematical models on simulation and MEG data recorded from a healthy individual during a somatosensory experiment and an epilepsy pediatric patient during sleep. We tested whether our technique can automatically extract salient dynamical features of cortical activity. Simulation results indicated that we can precisely reproduce the simulated cortical dynamics with HHD; encode them in sparse features and represent the propagation of brain activity between distinct cortical areas. Using HHD, we decoded the somatosensory N20 component into two HHD features and represented the dynamics of brain activity as a traveling source between two primary somatosensory regions. In the epilepsy patient, we displayed the propagation of the epileptic activity around the margins of a brain lesion. Our findings indicate that HHD measures computed from cortical dynamics can: (i) quantitatively access the cortical dynamics in both healthy and disease brain in terms of sparse features and dynamic brain activity propagation between distinct cortical areas, and (ii) facilitate a reproducible, automated analysis of experimental and clinical MEG/EEG source imaging data

    Differential activation of nerve fibers with magnetic stimulation in humans

    Get PDF
    Journal ArticleEarlier observations in our lab had indicated that large, time-varying magnetic fields could elicit action potentials that travel in only one direction in at least some of the myelinated axons in peripheral nerves. The objective of this study was to collect quantitative evidence for magnetically induced unidirectional action potentials in peripheral nerves of human subjects. A magnetic coil was maneuvered to a location on the upper arm where physical effects consistent with the creation of unidirectional action potentials were observed. Electromyographic (EMG) and somatosensory evoked potential (SEP) recordings were then made from a total of 20 subjects during stimulation with the magnetic coil

    Neuroanatomy and rehabilitation of the directional motor deficits associated with unilateral neglect

    Get PDF
    • …
    corecore