1,102 research outputs found

    The use of wearable/portable digital sensors in Huntington’s disease: a systematic review

    Get PDF
    In chronic neurological conditions, wearable/portable devices have potential as innovative tools to detect subtle early disease manifestations and disease fluctuations for the purpose of clinical diagnosis, care and therapeutic development. Huntington’s disease (HD) has a unique combination of motor and non-motor features which, combined with recent and anticipated therapeutic progress, gives great potential for such devices to prove useful. The present work aims to provide a comprehensive account of the use of wearable/portable devices in HD and of what they have contributed so far. We conducted a systematic review searching MEDLINE, Embase, and IEEE Xplore. Thirty references were identified. Our results revealed large variability in the types of sensors used, study design, and the measured outcomes. Digital technologies show considerable promise for therapeutic research and clinical management of HD. However, more studies with standardized devices and harmonized protocols are needed to optimize the potential applicability of wearable/portable devices in HD

    Shedding light on nocturnal movements in parkinson’s disease: Evidence from wearable technologies

    Get PDF
    In Parkinson’s disease (PD), abnormal movements consisting of hypokinetic and hyperkinetic manifestations commonly lead to nocturnal distress and sleep impairment, which significantly impact quality of life. In PD patients, these nocturnal disturbances can reflect diseaserelated complications (e.g., nocturnal akinesia), primary sleep disorders (e.g., rapid eye movement behaviour disorder), or both, thus requiring different therapeutic approaches. Wearable technologies based on actigraphy and innovative sensors have been proposed as feasible solutions to identify and monitor the various types of abnormal nocturnal movements in PD. This narrative review addresses the topic of abnormal nocturnal movements in PD and discusses how wearable technologies could help identify and assess these disturbances. We first examine the pathophysiology of abnormal nocturnal movements and the main clinical and instrumental tools for the evaluation of these disturbances in PD. We then report and discuss findings from previous studies assessing nocturnal movements in PD using actigraphy and innovative wearable sensors. Finally, we discuss clinical and technical prospects supporting the use of wearable technologies for the evaluation of nocturnal movements

    Wearable sensors system for an improved analysis of freezing of gait in Parkinson's disease using electromyography and inertial signals

    Get PDF
    We propose a wearable sensor system for automatic, continuous and ubiquitous analysis of Freezing of Gait (FOG), in patients affected by Parkinson's disease. FOG is an unpredictable gait disorder with different clinical manifestations, as the trembling and the shuffling-like phenotypes, whose underlying pathophysiology is not fully understood yet. Typical trembling-like subtype features are lack of postural adaptation and abrupt trunk inclination, which in general can increase the fall probability. The targets of this work are detecting the FOG episodes, distinguishing the phenotype and analyzing the muscle activity during and outside FOG, toward a deeper insight in the disorder pathophysiology and the assessment of the fall risk associated to the FOG subtype. To this aim, gyroscopes and surface electromyography integrated in wearable devices sense simultaneously movements and action potentials of antagonist leg muscles. Dedicated algorithms allow the timely detection of the FOG episode and, for the first time, the automatic distinction of the FOG phenotypes, which can enable associating a fall risk to the subtype. Thanks to the possibility of detecting muscles contractions and stretching exactly during FOG, a deeper insight into the pathophysiological underpinnings of the different phenotypes can be achieved, which is an innovative approach with respect to the state of art

    Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations

    Get PDF
    Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions

    Free-living monitoring of Parkinson’s disease: lessons from the field

    Get PDF
    Wearable technology comprises miniaturized sensors (e.g. accelerometers) worn on the body and/or paired with mobile devices (e.g. smart phones) allowing continuous patient monitoring in unsupervised, habitual environments (termed free-living). Wearable technologies are revolutionising approaches to healthcare due to their utility, accessibility and affordability. They are positioned to transform Parkinson’s disease (PD) management through provision of individualised, comprehensive, and representative data. This is particularly relevant in PD where symptoms are often triggered by task and free-living environmental challenges that cannot be replicated with sufficient veracity elsewhere. This review concerns use of wearable technology in free-living environments for people with PD. It outlines the potential advantages of wearable technologies and evidence for these to accurately detect and measure clinically relevant features including motor symptoms, falls risk, freezing of gait, gait, functional mobility and physical activity. Technological limitations and challenges are highlighted and advances concerning broader aspects are discussed. Recommendations to overcome key challenges are made. To date there is no fully validated system to monitor clinical features or activities in free living environments. Robust accuracy and validity metrics for some features have been reported, and wearable technology may be used in these cases with a degree of confidence. Utility and acceptability appears reasonable, although testing has largely been informal. Key recommendations include adopting a multi-disciplinary approach for standardising definitions, protocols and outcomes. Robust validation of developed algorithms and sensor-based metrics is required along with testing of utility. These advances are required before widespread clinical adoption of wearable technology can be realise

    Wearable Inertial Devices in Duchenne Muscular Dystrophy: A Scoping Review

    Get PDF
    In clinical practice and research, innovative digital technologies have been proposed for the characterization of neuromuscular and movement disorders through objective measures. Among these, wearable devices prove to be a suitable solution for tele-monitoring, tele-rehabilitation, and daily activities monitoring. Inertial Measurement Units (IMUs) are low-cost, compact, and easy-to-use wearable devices that evaluate kinematics during different movements. Kinematic variables could support the clinical evaluation of the progression of some neuromuscular diseases and could be used as outcome measures. The current review describes the use of IMUs for the biomechanical assessment of meaningful outcome measures in individuals affected by Duchenne muscular dystrophy (DMD). The PRISMA methodology was used and the search was conducted in different databases (Scopus, Web of Science, PubMed). A total of 23 articles were examined and classified according to year of publication, ambulatory/non-ambulatory subjects, and IMU positioning on human body. The analysis points out the recent regulatory identification of Stride Velocity 95th Centile as a new endpoint in therapeutic DMD trials when measured continuously from a wearable device, while only a few studies proposed the use of IMUs in non-ambulatory patients. Clinical recognition of reliable and accurate outcome measures for the upper body is still a challeng

    Wearable inertial sensors as a tool for quantitative assessment of progress during rehabilitation

    Get PDF
    Biomechanics analysis is frequently used in both clinical and sporting practice in order to assess human motion and performance of defined tasks. Whilst camera-based motion systems have long been regarded as the ‘Goldstandard’ for quantitative movement-based analysis, their application is not without limitations as regards potential sources of variability in measurements, high costs, and practicality of use for larger patient/subject groups. Another more practical approach, which presents itself as a viable solution to biomechanical motion capture and monitoring in sporting and patient groups, is through the use of small-size low-cost wearable Micro-ElectroMechanical Systems (MEMs)- based inertial sensors. The clinical aim of the present work is to evaluate gait during rehabilitation following knee injuries and to identify gait abnormalities through a wireless inertial sensing system. This system was developed at the Tyndall National Institute to meet clinician-defined needs, and is able to provide a complete biomechanics assessment without the constraints of a motion capture laboratory. The derived motion parameter outcomes can be analyzed by clinicians and sport scientists to study the overall patients’ condition and provide accurate medical feedback as to their rehabilitative progress. Detection of atypical movement characteristics is possible by comparing the performance and variability in motion characteristics in the patient’s affected and unaffected lower-limbs. The work is ongoing, and to date the system has been tested on only one impaired subject, additional clinical trials are currently being planned with an enhanced number of injured subjects. This will provide a more robust statistical analysis of the data in the study. The present feasibility study proved that inertial sensors can be used for a quantitative assessment of knee joint mobility, and gait mechanics during the rehabilitation program of injured subjects and can provide valuable information to clinical experts as regards patient rehabilitation

    Empowering patients in self-management of parkinson's disease through cooperative ICT systems

    Get PDF
    The objective of this chapter is to demonstrate the technical feasibility and medical effectiveness of personalised services and care programmes for Parkinson's disease, based on the combination of mHealth applications, cooperative ICTs, cloud technologies and wearable integrated devices, which empower patients to manage their health and disease in cooperation with their formal and informal caregivers, and with professional medical staff across different care settings, such as hospital and home. The presented service revolves around the use of two wearable inertial sensors, i.e. SensFoot and SensHand, for measuring foot and hand performance in the MDS-UPDRS III motor exercises. The devices were tested in medical settings with eight patients, eight hyposmic subjects and eight healthy controls, and the results demonstrated that this approach allows quantitative metrics for objective evaluation to be measured, in order to identify pre-motor/pre-clinical diagnosis and to provide a complete service of tele-health with remote control provided by cloud technologies. © 2016, IGI Global. All rights reserved

    An Overview of Smart Shoes in the Internet of Health Things: Gait and Mobility Assessment in Health Promotion and Disease Monitoring

    Get PDF
    New smart technologies and the internet of things increasingly play a key role in healthcare and wellness, contributing to the development of novel healthcare concepts. These technologies enable a comprehensive view of an individual’s movement and mobility, potentially supporting healthy living as well as complementing medical diagnostics and the monitoring of therapeutic outcomes. This overview article specifically addresses smart shoes, which are becoming one such smart technology within the future internet of health things, since the ability to walk defines large aspects of quality of life in a wide range of health and disease conditions. Smart shoes offer the possibility to support prevention, diagnostic work-up, therapeutic decisions, and individual disease monitoring with a continuous assessment of gait and mobility. This overview article provides the technological as well as medical aspects of smart shoes within this rising area of digital health applications, and is designed especially for the novel reader in this specific field. It also stresses the need for closer interdisciplinary interactions between technological and medical experts to bridge the gap between research and practice. Smart shoes can be envisioned to serve as pervasive wearable computing systems that enable innovative solutions and services for the promotion of healthy living and the transformation of health care
    corecore