1,392 research outputs found

    Virtual and Augmented Reality Techniques for Minimally Invasive Cardiac Interventions: Concept, Design, Evaluation and Pre-clinical Implementation

    Get PDF
    While less invasive techniques have been employed for some procedures, most intracardiac interventions are still performed under cardiopulmonary bypass, on the drained, arrested heart. The progress toward off-pump intracardiac interventions has been hampered by the lack of adequate visualization inside the beating heart. This thesis describes the development, assessment, and pre-clinical implementation of a mixed reality environment that integrates pre-operative imaging and modeling with surgical tracking technologies and real-time ultrasound imaging. The intra-operative echo images are augmented with pre-operative representations of the cardiac anatomy and virtual models of the delivery instruments tracked in real time using magnetic tracking technologies. As a result, the otherwise context-less images can now be interpreted within the anatomical context provided by the anatomical models. The virtual models assist the user with the tool-to-target navigation, while real-time ultrasound ensures accurate positioning of the tool on target, providing the surgeon with sufficient information to ``see\u27\u27 and manipulate instruments in absence of direct vision. Several pre-clinical acute evaluation studies have been conducted in vivo on swine models to assess the feasibility of the proposed environment in a clinical context. Following direct access inside the beating heart using the UCI, the proposed mixed reality environment was used to provide the necessary visualization and navigation to position a prosthetic mitral valve on the the native annulus, or to place a repair patch on a created septal defect in vivo in porcine models. Following further development and seamless integration into the clinical workflow, we hope that the proposed mixed reality guidance environment may become a significant milestone toward enabling minimally invasive therapy on the beating heart

    Dynamic Image Processing for Guidance of Off-pump Beating Heart Mitral Valve Repair

    Get PDF
    Compared to conventional open heart procedures, minimally invasive off-pump beating heart mitral valve repair aims to deliver equivalent treatment for mitral regurgitation with reduced trauma and side effects. However, minimally invasive approaches are often limited by the lack of a direct view to surgical targets and/or tools, a challenge that is compounded by potential movement of the target during the cardiac cycle. For this reason, sophisticated image guidance systems are required in achieving procedural efficiency and therapeutic success. The development of such guidance systems is associated with many challenges. For example, the system should be able to provide high quality visualization of both cardiac anatomy and motion, as well as augmenting it with virtual models of tracked tools and targets. It should have the capability of integrating pre-operative images to the intra-operative scenario through registration techniques. The computation speed must be sufficiently fast to capture the rapid cardiac motion. Meanwhile, the system should be cost effective and easily integrated into standard clinical workflow. This thesis develops image processing techniques to address these challenges, aiming to achieve a safe and efficient guidance system for off-pump beating heart mitral valve repair. These techniques can be divided into two categories, using 3D and 2D image data respectively. When 3D images are accessible, a rapid multi-modal registration approach is proposed to link the pre-operative CT images to the intra-operative ultrasound images. The ultrasound images are used to display the real time cardiac motion, enhanced by CT data serving as high quality 3D context with annotated features. I also developed a method to generate synthetic dynamic CT images, aiming to replace real dynamic CT data in such a guidance system to reduce the radiation dose applied to the patients. When only 2D images are available, an approach is developed to track the feature of interest, i.e. the mitral annulus, based on bi-plane ultrasound images and a magnetic tracking system. The concept of modern GPU-based parallel computing is employed in most of these approaches to accelerate the computation in order to capture the rapid cardiac motion with desired accuracy. Validation experiments were performed on phantom, animal and human data. The overall accuracy of registration and feature tracking with respect to the mitral annulus was about 2-3mm with computation time of 60-400ms per frame, sufficient for one update per cardiac cycle. It was also demonstrated in the results that the synthetic CT images can provide very similar anatomical representations and registration accuracy compared to that of the real dynamic CT images. These results suggest that the approaches developed in the thesis have good potential for a safer and more effective guidance system for off-pump beating heart mitral valve repair

    Augmented reality (AR) for surgical robotic and autonomous systems: State of the art, challenges, and solutions

    Get PDF
    Despite the substantial progress achieved in the development and integration of augmented reality (AR) in surgical robotic and autonomous systems (RAS), the center of focus in most devices remains on improving end-effector dexterity and precision, as well as improved access to minimally invasive surgeries. This paper aims to provide a systematic review of different types of state-of-the-art surgical robotic platforms while identifying areas for technological improvement. We associate specific control features, such as haptic feedback, sensory stimuli, and human-robot collaboration, with AR technology to perform complex surgical interventions for increased user perception of the augmented world. Current researchers in the field have, for long, faced innumerable issues with low accuracy in tool placement around complex trajectories, pose estimation, and difficulty in depth perception during two-dimensional medical imaging. A number of robots described in this review, such as Novarad and SpineAssist, are analyzed in terms of their hardware features, computer vision systems (such as deep learning algorithms), and the clinical relevance of the literature. We attempt to outline the shortcomings in current optimization algorithms for surgical robots (such as YOLO and LTSM) whilst providing mitigating solutions to internal tool-to-organ collision detection and image reconstruction. The accuracy of results in robot end-effector collisions and reduced occlusion remain promising within the scope of our research, validating the propositions made for the surgical clearance of ever-expanding AR technology in the future

    Simulating Developmental Cardiac Morphology in Virtual Reality Using a Deformable Image Registration Approach

    Get PDF
    While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registration (DIR) in conjunction with 3-D reconstruction and VR implementation to recapitulate developmental cardiac contractile function from light-sheet fluorescence microscopy (LSFM). This method addressed inconsistencies that would arise from independent segmentations of time-dependent data, thereby enabling the creation of a VR environment that fluently simulates cardiac morphological changes. By analyzing myocardial deformation at high spatiotemporal resolution, we interfaced quantitative computations with 4-D VR. We demonstrated that our LSFM-captured images, followed by DIR, yielded average dice similarity coefficients of 0.92 ± 0.05 (n = 510) and 0.93 ± 0.06 (n = 240) when compared to ground truth images obtained from Otsu thresholding and manual segmentation, respectively. The resulting VR environment simulates a wide-angle zoomed-in view of motion in live embryonic zebrafish hearts, in which the cardiac chambers are undergoing structural deformation throughout the cardiac cycle. Thus, this technique allows for an interactive micro-scale VR visualization of developmental cardiac morphology to enable high resolution simulation for both basic and clinical science

    Virtual Reality Based Environment for Orthopedic Surgery (Veos)

    Get PDF
    The traditional way of teaching surgery involves students observing a �live� surgery and then gradually assisting experienced surgeons. The creation of a Virtual Reality environment for orthopedic surgery (VEOS) can be beneficial in improving the quality of training while decreasing the time needed for training. Developing such virtual environments for educational and training purposes can supplement existing approaches. In this research, the design and development of a virtual reality based environment for orthopedic surgery is described. The scope of the simulation environment is restricted to an orthopedic surgery process known as Less Invasive Stabilization System (LISS) surgery. The primary knowledge source for the LISS surgical process was Miguel A. Pirela-Cruz (Head of Orthopedic Surgery and Rehabilitation, Texas Tech University Health Sciences Center (TTHSC)). The VEOS was designed and developed on a PC based platform. The developed VEOS was validated through interactions with surgical residents at TTHSC. Feedback from residents and our collaborator Miguel A. Pirela-Cruz was used to make necessary modifications to the surgical environment.Industrial Engineering & Managemen

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Exploiting Temporal Image Information in Minimally Invasive Surgery

    Get PDF
    Minimally invasive procedures rely on medical imaging instead of the surgeons direct vision. While preoperative images can be used for surgical planning and navigation, once the surgeon arrives at the target site real-time intraoperative imaging is needed. However, acquiring and interpreting these images can be challenging and much of the rich temporal information present in these images is not visible. The goal of this thesis is to improve image guidance for minimally invasive surgery in two main areas. First, by showing how high-quality ultrasound video can be obtained by integrating an ultrasound transducer directly into delivery devices for beating heart valve surgery. Secondly, by extracting hidden temporal information through video processing methods to help the surgeon localize important anatomical structures. Prototypes of delivery tools, with integrated ultrasound imaging, were developed for both transcatheter aortic valve implantation and mitral valve repair. These tools provided an on-site view that shows the tool-tissue interactions during valve repair. Additionally, augmented reality environments were used to add more anatomical context that aids in navigation and in interpreting the on-site video. Other procedures can be improved by extracting hidden temporal information from the intraoperative video. In ultrasound guided epidural injections, dural pulsation provides a cue in finding a clear trajectory to the epidural space. By processing the video using extended Kalman filtering, subtle pulsations were automatically detected and visualized in real-time. A statistical framework for analyzing periodicity was developed based on dynamic linear modelling. In addition to detecting dural pulsation in lumbar spine ultrasound, this approach was used to image tissue perfusion in natural video and generate ventilation maps from free-breathing magnetic resonance imaging. A second statistical method, based on spectral analysis of pixel intensity values, allowed blood flow to be detected directly from high-frequency B-mode ultrasound video. Finally, pulsatile cues in endoscopic video were enhanced through Eulerian video magnification to help localize critical vasculature. This approach shows particular promise in identifying the basilar artery in endoscopic third ventriculostomy and the prostatic artery in nerve-sparing prostatectomy. A real-time implementation was developed which processed full-resolution stereoscopic video on the da Vinci Surgical System

    Augmented Reality (AR) for Surgical Robotic and Autonomous Systems: State of the Art, Challenges, and Solutions

    Get PDF
    Despite the substantial progress achieved in the development and integration of augmented reality (AR) in surgical robotic and autonomous systems (RAS), the center of focus in most devices remains on improving end-effector dexterity and precision, as well as improved access to minimally invasive surgeries. This paper aims to provide a systematic review of different types of state-of-the-art surgical robotic platforms while identifying areas for technological improvement. We associate specific control features, such as haptic feedback, sensory stimuli, and human–robot collaboration, with AR technology to perform complex surgical interventions for increased user perception of the augmented world. Current researchers in the field have, for long, faced innumerable issues with low accuracy in tool placement around complex trajectories, pose estimation, and difficulty in depth perception during two-dimensional medical imaging. A number of robots described in this review, such as Novarad and SpineAssist, are analyzed in terms of their hardware features, computer vision systems (such as deep learning algorithms), and the clinical relevance of the literature. We attempt to outline the shortcomings in current optimization algorithms for surgical robots (such as YOLO and LTSM) whilst providing mitigating solutions to internal tool-to-organ collision detection and image reconstruction. The accuracy of results in robot end-effector collisions and reduced occlusion remain promising within the scope of our research, validating the propositions made for the surgical clearance of ever-expanding AR technology in the future

    Intracardiac Ultrasound Guided Systems for Transcatheter Cardiac Interventions

    Get PDF
    Transcatheter cardiac interventions are characterized by their percutaneous nature, increased patient safety, and low hospitalization times. Transcatheter procedures involve two major stages: navigation towards the target site and the positioning of tools to deliver the therapy, during which the interventionalists face the challenge of visualizing the anatomy and the relative position of the tools such as a guidewire. Fluoroscopic and transesophageal ultrasound (TEE) imaging are the most used techniques in cardiac procedures; however, they possess the disadvantage of radiation exposure and suboptimal imaging. This work explores the potential of intracardiac ultrasound (ICE) within an image guidance system (IGS) to facilitate the two stages of cardiac interventions. First, a novel 2.5D side-firing, conical Foresight ICE probe (Conavi Medical Inc., Toronto) is characterized, calibrated, and tracked using an electromagnetic sensor. The results indicate an acceptable tracking accuracy within some limitations. Next, an IGS is developed for navigating the vessels without fluoroscopy. A forward-looking, tracked ICE probe is used to reconstruct the vessel on a phantom which mimics the ultrasound imaging of an animal vena cava. Deep learning methods are employed to segment the complex vessel geometry from ICE imaging for the first time. The ICE-reconstructed vessel showed a clinically acceptable range of accuracy. Finally, a guidance system was developed to facilitate the positioning of tools during a tricuspid valve repair. The designed system potentially facilitates the positioning of the TriClip at the coaptation gap by pre-mapping the corresponding site of regurgitation in 3D tracking space

    Three-dimensional echocardiographic virtual endoscopy for the diagnosis of congenital heart disease in children

    Get PDF
    Virtual endoscopy (VE) is a new post-processing method that uses volumetric data sets to simulate the tracks of a “conventional” flexible endoscope. However, almost all studies of this method have involved virtual visualizations of the cardiovascular structures applied to computed tomography (CT) and magnetic resonance (MR) datasets. This paper introduces a novel visualization method called the “three-dimensional echocardiographic intracardiac endoscopic simulation system (3DE IESS)”, which uses 3D echocardiographic images in a virtual reality (VR) environment to diagnose congenital heart disease. The aim of this study was to analyze the feasibility of VE in the evaluation of congenital heart disease in children and its accuracy compared with 2DE. Three experienced pediatric cardiologists blinded to the patients’ diagnoses separately reviewed 40 two-dimensional echocardiographic (2DE) datasets and 40 corresponding VE datasets and judged whether abnormal intracardiac anatomy was present in terms of a five-point scale (1 = definitely absent; 2 = probably absent; 3 = cannot be determined; 4 = probably present; and 5 = definitely present). Compared with clinical diagnosis, the diagnostic accuracy of VE was 98.7% for ASD, 92.4% for VSD, 92.6% for TOF, and 94% for DORV, respectively. Diagnostic accuracy of VE was significantly higher than that of 2DE for TOF and DORV except for ASD and VSD. The receiver operating characteristic (ROC) curve for VE was closer to the optimal performance point than was the ROC curve for 2DE. The area under the ROC curve was 0.96 for VE and 0.93 for 2DE. Kappa values (range, 0.73–0.79) for VE and 2DE indicated substantial agreement. 3D echocardiographic VE can enhance our understanding of intracardiac structures and facilitate the evaluation of congenital heart disease
    corecore