8,056 research outputs found
Robust Cardiac Motion Estimation using Ultrafast Ultrasound Data: A Low-Rank-Topology-Preserving Approach
Cardiac motion estimation is an important diagnostic tool to detect heart
diseases and it has been explored with modalities such as MRI and conventional
ultrasound (US) sequences. US cardiac motion estimation still presents
challenges because of the complex motion patterns and the presence of noise. In
this work, we propose a novel approach to estimate the cardiac motion using
ultrafast ultrasound data. -- Our solution is based on a variational
formulation characterized by the L2-regularized class. The displacement is
represented by a lattice of b-splines and we ensure robustness by applying a
maximum likelihood type estimator. While this is an important part of our
solution, the main highlight of this paper is to combine a low-rank data
representation with topology preservation. Low-rank data representation
(achieved by finding the k-dominant singular values of a Casorati Matrix
arranged from the data sequence) speeds up the global solution and achieves
noise reduction. On the other hand, topology preservation (achieved by
monitoring the Jacobian determinant) allows to radically rule out distortions
while carefully controlling the size of allowed expansions and contractions.
Our variational approach is carried out on a realistic dataset as well as on a
simulated one. We demonstrate how our proposed variational solution deals with
complex deformations through careful numerical experiments. While maintaining
the accuracy of the solution, the low-rank preprocessing is shown to speed up
the convergence of the variational problem. Beyond cardiac motion estimation,
our approach is promising for the analysis of other organs that experience
motion.Comment: 15 pages, 10 figures, Physics in Medicine and Biology, 201
Characterization of age-related microstructural changes in locus coeruleus and substantia nigra pars compacta.
Locus coeruleus (LC) and substantia nigra pars compacta (SNpc) degrade with normal aging, but not much is known regarding how these changes manifest in MRI images, or whether these markers predict aspects of cognition. Here, we use high-resolution diffusion-weighted MRI to investigate microstructural and compositional changes in LC and SNpc in young and older adult cohorts, as well as their relationship with cognition. In LC, the older cohort exhibited a significant reduction in mean and radial diffusivity, but a significant increase in fractional anisotropy compared with the young cohort. We observed a significant correlation between the decrease in LC mean, axial, and radial diffusivities and measures examining cognition (Rey Auditory Verbal Learning Test delayed recall) in the older adult cohort. This observation suggests that LC is involved in retaining cognitive abilities. In addition, we observed that iron deposition in SNpc occurs early in life and continues during normal aging
Recommended from our members
Global morphogenetic flow is accurately predicted by the spatial distribution of myosin motors.
During embryogenesis tissue layers undergo morphogenetic flow rearranging and folding into specific shapes. While developmental biology has identified key genes and local cellular processes, global coordination of tissue remodeling at the organ scale remains unclear. Here, we combine in toto light-sheet microscopy of the Drosophila embryo with quantitative analysis and physical modeling to relate cellular flow with the patterns of force generation during the gastrulation process. We find that the complex spatio-temporal flow pattern can be predicted from the measured meso-scale myosin density and anisotropy using a simple, effective viscous model of the tissue, achieving close to 90% accuracy with one time dependent and two constant parameters. Our analysis uncovers the importance of a) spatial modulation of myosin distribution on the scale of the embryo and b) the non-locality of its effect due to mechanical interaction of cells, demonstrating the need for the global perspective in the study of morphogenetic flow
Wavelet Features for Recognition of First Episode of Schizophrenia from MRI Brain Images
Machine learning methods are increasingly used in various fields of medicine, contributing to early diagnosis and better quality of care. These outputs are particularly desirable in case of neuropsychiatric disorders, such as schizophrenia, due to the inherent potential for creating a new gold standard in the diagnosis and differentiation of particular disorders. This paper presents a scheme for automated classification from magnetic resonance images based on multiresolution representation in the wavelet domain. Implementation of the proposed algorithm, utilizing support vector machines classifier, is introduced and tested on a dataset containing 104 patients with first episode schizophrenia and healthy volunteers. Optimal parameters of different phases of the algorithm are sought and the quality of classification is estimated by robust cross validation techniques. Values of accuracy, sensitivity and specificity over 71% are achieved
Motion compensated micro-CT reconstruction for in-situ analysis of dynamic processes
This work presents a framework to exploit the synergy between Digital Volume Correlation ( DVC) and iterative CT reconstruction to enhance the quality of high-resolution dynamic X-ray CT (4D-mu CT) and obtain quantitative results from the acquired dataset in the form of 3D strain maps which can be directly correlated to the material properties. Furthermore, we show that the developed framework is capable of strongly reducing motion artifacts even in a dataset containing a single 360 degrees rotation
Bayesian Framework for Simultaneous Registration and Estimation of Noisy, Sparse and Fragmented Functional Data
Mathematical and Physical Sciences: 3rd Place (The Ohio State University Edward F. Hayes Graduate Research Forum)In many applications, smooth processes generate data that is recorded under a variety of observation regimes, such as dense sampling and sparse or fragmented observations that are often contaminated with error. The statistical goal of registering and estimating the individual underlying functions from discrete observations has thus far been mainly approached sequentially without formal uncertainty propagation, or in an application-specific manner by pooling information across subjects. We propose a unified Bayesian framework for simultaneous registration and estimation, which is flexible enough to accommodate inference on individual functions under general observation regimes. Our ability to do this relies on the specification of strongly informative prior models over the amplitude component of function variability. We provide two strategies for this critical choice: a data-driven approach that defines an empirical basis for the amplitude subspace based on available training data, and a shape-restricted approach when the relative location and number of local extrema is well-understood. The proposed methods build on the elastic functional data analysis framework to separately model amplitude and phase variability inherent in functional data. We emphasize the importance of uncertainty quantification and visualization of these two components as they provide complementary information about the estimated functions. We validate the proposed framework using simulation studies, and real applications to estimation of fractional anisotropy profiles based on diffusion tensor imaging measurements, growth velocity functions and bone mineral density curves.No embarg
A poroelastic model coupled to a fluid network with applications in lung modelling
Here we develop a lung ventilation model, based a continuum poroelastic
representation of lung parenchyma and a 0D airway tree flow model. For the
poroelastic approximation we design and implement a lowest order stabilised
finite element method. This component is strongly coupled to the 0D airway tree
model. The framework is applied to a realistic lung anatomical model derived
from computed tomography data and an artificially generated airway tree to
model the conducting airway region. Numerical simulations produce
physiologically realistic solutions, and demonstrate the effect of airway
constriction and reduced tissue elasticity on ventilation, tissue stress and
alveolar pressure distribution. The key advantage of the model is the ability
to provide insight into the mutual dependence between ventilation and
deformation. This is essential when studying lung diseases, such as chronic
obstructive pulmonary disease and pulmonary fibrosis. Thus the model can be
used to form a better understanding of integrated lung mechanics in both the
healthy and diseased states
Insight into the fundamental trade-offs of diffusion MRI from polarization-sensitive optical coherence tomography in ex vivo human brain
In the first study comparing high angular resolution diffusion MRI (dMRI) in the human brain to axonal orientation measurements from polarization-sensitive optical coherence tomography (PSOCT), we compare the accuracy of orientation estimates from various dMRI sampling schemes and reconstruction methods. We find that, if the reconstruction approach is chosen carefully, single-shell dMRI data can yield the same accuracy as multi-shell data, and only moderately lower accuracy than a full Cartesian-grid sampling scheme. Our results suggest that current dMRI reconstruction approaches do not benefit substantially from ultra-high b-values or from very large numbers of diffusion-encoding directions. We also show that accuracy remains stable across dMRI voxel sizes of 1 mm or smaller but degrades at 2 mm, particularly in areas of complex white-matter architecture. We also show that, as the spatial resolution is reduced, axonal configurations in a dMRI voxel can no longer be modeled as a small set of distinct axon populations, violating an assumption that is sometimes made by dMRI reconstruction techniques. Our findings have implications for in vivo studies and illustrate the value of PSOCT as a source of ground-truth measurements of white-matter organization that does not suffer from the distortions typical of histological techniques.Published versio
- …