4 research outputs found

    Studies of the relationship between the surface electromyogram, joint torque and impedance

    Get PDF
    This compendium-format dissertation (i.e., comprised mostly of published and in-process articles) primarily reports on system identification methods that relate the surface electromyogram (EMG)—the electrical activity of skeletal muscles—to mechanical kinetics. The methods focus on activities of the elbow and hand-wrist. The relationship between the surface EMG and joint impedance was initially studied. My work provided a complete second-order EMG-based impedance characterization of stiffness, viscosity and inertia over a complete range of nominal torques, from a single perturbation trial with slowly varied torque. A single perturbation trial provides a more convenient method for impedance evaluation. The RMS errors of the EMG-based method were 20.01% for stiffness and 7.05% for viscosity, compared with the traditional mechanical measurement. Three projects studied the relationship between EMG and force/torque, a topic that has been studied for a number of years. Optimal models use whitened EMG amplitude, combining multiple EMG channels and a polynomial equation to describe this relationship. First, we used three techniques to improve current models at the elbow joint. Three more features were extracted from the EMG (waveform length, slope sign change rate and zero crossing rate), in addition to EMG amplitude. Each EMG channel was used separately, compared to previous studies which combined multiple channels from biceps and, separately, from triceps muscles. Finally, an exponential power law model was used. Each of these improvement techniques showed better performance (P\u3c0.05 and ~0.7 percent maximum voluntary contraction (%MVC) error reduction from a nominal error of 5.5%MVC) than the current “optimal” model. However, the combination of pairs of these techniques did not further improve results. Second, traditional prostheses only control 1 degree of freedom (DoF) at a time. My work provided evidence for the feasibility of controlling 2-DoF wrist movements simultaneously, with a minimum number of electrodes. Results suggested that as few as four conventional electrodes, optimally located about the forearm, could provide 2-DoF simultaneous, independent and proportional control with error ranging from 9.0–10.4 %MVC, which is similar to the 1-DoF approach (error from 8.8–9.8 %MVC) currently used for commercial prosthesis control. The third project was similar to the second, except that this project studied controlling a 1-DoF wrist with one hand DoF simultaneously. It also demonstrated good performance with the error ranging from 7.8-8.7 %MVC, compared with 1-DoF control. Additionally, I participated in two team projects—EMG decomposition and static wrist EMG to torque—which are described herein

    EMG Signal Decomposition Using Motor Unit Potential Train Validity

    Get PDF
    Electromyographic (EMG) signal decomposition is the process of resolving an EMG signal into its component motor unit potential trains (MUPTs). The extracted MUPTs can aid in the diagnosis of neuromuscular disorders and the study of the neural control of movement, but only if they are valid trains. Before using decomposition results and the motor unit potential (MUP) shape and motor unit (MU) firing pattern information related to each active MU for either clinical or research purposes the fact that the extracted MUPTs are valid needs to be confirmed. The existing MUPT validation methods are either time consuming or related to operator experience and skill. More importantly, they cannot be executed during automatic decomposition of EMG signals to assist with improving decomposition results. To overcome these issues, in this thesis the possibility of developing automatic MUPT validation algorithms has been explored. Several methods based on a combination of feature extraction techniques, cluster validation methods, supervised classification algorithms, and multiple classifier fusion techniques were developed. The developed methods, in general, use either the MU firing pattern or MUP-shape consistency of a MUPT, or both, to estimate its overall validity. The performance of the developed systems was evaluated using a variety of MUPTs obtained from the decomposition of several simulated and real intramuscular EMG signals. Based on the results achieved, the methods that use only shape or only firing pattern information had higher generalization error than the systems that use both types of information. For the classifiers that use MU firing pattern information of a MUPT to determine its validity, the accuracy for invalid trains decreases as the number of missed-classification errors in trains increases. Likewise, for the methods that use MUP-shape information of a MUPT to determine its validity, the classification accuracy for invalid trains decreases as the within-train similarity of the invalid trains increase. Of the systems that use both shape and firing pattern information, those that separately estimate MU firing pattern validity and MUP-shape validity and then estimate the overall validity of a train by fusing these two indices using trainable fusion methods performed better than the single classifier scheme that estimates MUPT validity using a single classifier, especially for the real data used. Overall, the multi-classifier constructed using trainable logistic regression to aggregate base classifier outputs had the best performance with overall accuracy of 99.4% and 98.8% for simulated and real data, respectively. The possibility of formulating an algorithm for automated editing MUPTs contaminated with a high number of false-classification errors (FCEs) during decomposition was also investigated. Ultimately, a robust method was developed for this purpose. Using a supervised classifier and MU firing pattern information provided by each MUPT, the developed algorithm first determines whether a given train is contaminated by a high number of FCEs and needs to be edited. For contaminated MUPTs, the method uses both MU firing pattern and MUP shape information to detect MUPs that were erroneously assigned to the train. Evaluation based on simulated and real MU firing patterns, shows that contaminated MUPTs could be detected with 84% and 81% accuracy for simulated and real data, respectively. For a given contaminated MUPT, the algorithm on average correctly classified around 92.1% of the MUPs of the MUPT. The effectiveness of using the developed MUPT validation systems and the MUPT editing methods during EMG signal decomposition was investigated by integrating these algorithms into a certainty-based EMG signal decomposition algorithm. Overall, the decomposition accuracy for 32 simulated and 30 real EMG signals was improved by 7.5% (from 86.7% to 94.2%) and 3.4% (from 95.7% to 99.1%), respectively. A significant improvement was also achieved in correctly estimating the number of MUPTs represented in a set of detected MUPs. The simulated and real EMG signals used were comprised of 3–11 and 3–15 MUPTs, respectively

    Unsupervised Bayesian Decomposition of Multiunit EMG Recordings Using Tabu Search

    Get PDF
    International audienceIntramuscular electromyography (EMG) signals are usually decomposed with semiautomatic procedures that involve the interaction with an expert operator. In this paper, a Bayesian statistical model and a maximum a posteriori (MAP) estimator are used to solve the problem of multiunit EMG decomposition in a fully automatic way. The MAP estimation exploits both the like- lihood of the reconstructed EMG signal and some physiological constraints, such as the discharge pattern regularity and the re- fractory period of muscle fibers, as prior information integrated in a Bayesian framework. A Tabu search is proposed to efficiently tackle the nondeterministic polynomial-time-hard problem of op- timization w.r.t the motor unit discharge patterns. The method is fully automatic and was tested on simulated and experimen- tal EMG signals. Compared with the semiautomatic decomposi- tion performed by an expert operator, the proposed method re- sulted in an accuracy of 90.0% ± 3.8% when decomposing single- channel intramuscular EMG signals recorded from the abduc- tor digiti minimi muscle at contraction forces of 5% and 10% of the maximal force. The method can also be applied to the auto- matic identification and classification of spikes from other neural recordings

    Unsupervised Bayesian Decomposition of Multiunit EMG Recordings Using Tabu Search

    No full text
    corecore