42 research outputs found

    Foetal echocardiographic segmentation

    Get PDF
    Congenital heart disease affects just under one percentage of all live births [1]. Those defects that manifest themselves as changes to the cardiac chamber volumes are the motivation for the research presented in this thesis. Blood volume measurements in vivo require delineation of the cardiac chambers and manual tracing of foetal cardiac chambers is very time consuming and operator dependent. This thesis presents a multi region based level set snake deformable model applied in both 2D and 3D which can automatically adapt to some extent towards ultrasound noise such as attenuation, speckle and partial occlusion artefacts. The algorithm presented is named Mumford Shah Sarti Collision Detection (MSSCD). The level set methods presented in this thesis have an optional shape prior term for constraining the segmentation by a template registered to the image in the presence of shadowing and heavy noise. When applied to real data in the absence of the template the MSSCD algorithm is initialised from seed primitives placed at the centre of each cardiac chamber. The voxel statistics inside the chamber is determined before evolution. The MSSCD stops at open boundaries between two chambers as the two approaching level set fronts meet. This has significance when determining volumes for all cardiac compartments since cardiac indices assume that each chamber is treated in isolation. Comparison of the segmentation results from the implemented snakes including a previous level set method in the foetal cardiac literature show that in both 2D and 3D on both real and synthetic data, the MSSCD formulation is better suited to these types of data. All the algorithms tested in this thesis are within 2mm error to manually traced segmentation of the foetal cardiac datasets. This corresponds to less than 10% of the length of a foetal heart. In addition to comparison with manual tracings all the amorphous deformable model segmentations in this thesis are validated using a physical phantom. The volume estimation of the phantom by the MSSCD segmentation is to within 13% of the physically determined volume

    Basic Science to Clinical Research: Segmentation of Ultrasound and Modelling in Clinical Informatics

    Get PDF
    The world of basic science is a world of minutia; it boils down to improving even a fraction of a percent over the baseline standard. It is a domain of peer reviewed fractions of seconds and the world of squeezing every last ounce of efficiency from a processor, a storage medium, or an algorithm. The field of health data is based on extracting knowledge from segments of data that may improve some clinical process or practice guideline to improve the time and quality of care. Clinical informatics and knowledge translation provide this information in order to reveal insights to the world of improving patient treatments, regimens, and overall outcomes. In my world of minutia, or basic science, the movement of blood served an integral role. The novel detection of sound reverberations map out the landscape for my research. I have applied my algorithms to the various anatomical structures of the heart and artery system. This serves as a basis for segmentation, active contouring, and shape priors. The algorithms presented, leverage novel applications in segmentation by using anatomical features of the heart for shape priors and the integration of optical flow models to improve tracking. The presented techniques show improvements over traditional methods in the estimation of left ventricular size and function, along with plaque estimation in the carotid artery. In my clinical world of data understanding, I have endeavoured to decipher trends in Alzheimer’s disease, Sepsis of hospital patients, and the burden of Melanoma using mathematical modelling methods. The use of decision trees, Markov models, and various clustering techniques provide insights into data sets that are otherwise hidden. Finally, I demonstrate how efficient data capture from providers can achieve rapid results and actionable information on patient medical records. This culminated in generating studies on the burden of illness and their associated costs. A selection of published works from my research in the world of basic sciences to clinical informatics has been included in this thesis to detail my transition. This is my journey from one contented realm to a turbulent one

    Methodology for Jointly Assessing Myocardial Infarct Extent and Regional Contraction in 3-D CMRI

    Full text link
    Automated extraction of quantitative parameters from Cardiac Magnetic Resonance Images (CMRI) is crucial for the management of patients with myocardial infarct. This work proposes a post-processing procedure to jointly analyze Cine and Delayed-Enhanced (DE) acquisitions in order to provide an automatic quantification of myocardial contraction and enhancement parameters and a study of their relationship. For that purpose, the following processes are performed: 1) DE/Cine temporal synchronization and 3D scan alignment, 2) 3D DE/Cine rigid registration in a region about the heart, 3) segmentation of the myocardium on Cine MRI and superimposition of the epicardial and endocardial contours on the DE images, 4) quantification of the Myocardial Infarct Extent (MIE), 5) study of the regional contractile function using a new index, the Amplitude to Time Ratio (ATR). The whole procedure was applied to 10 patients with clinically proven myocardial infarction. The comparison between the MIE and the visually assessed regional function scores demonstrated that the MIE is highly related to the severity of the wall motion abnormality. In addition, it was shown that the newly developed regional myocardial contraction parameter (ATR) decreases significantly in delayed enhanced regions. This largely automated approach enables a combined study of regional MIE and left ventricular function

    Segmentation in Echocardiographic Sequences Using Shape-based Snake Model

    Get PDF
    A method for segmentation of cardiac structures especially for mitral valve in echocardiographic sequences is presented. The method is motivated by the observation that the structures of neighboring frames have consistent locations and shapes that aid in segmentation. To cooperate with the constraining information provided by the neighboring frames, we combine the template matching with the conventional snake model. It means that the model not only is driven by conventional internal and external forces, but also combines an additional constraint, the matching degree to measure the similarity between the neighboring prior shape and the derived contour. Furthermore, in order to automatically or semi-automatically segment the sequent images without manually drawing the initial contours in each image, generalized Hough transformation (GHT) is used to roughly estimate the initial contour by transforming the neighboring prior shape. Based on the experiments on forty sequences, the method is particularly useful in case of the large frame-to-frame displacement of structure such as mitral valve. As a result, the active contour can easily detect the desirable boundaries in ultrasound images and has a high penetrability through the interference of various undesirables, such as the speckle, the tissue-related textures and the artifacts

    Automated segmentation of soft tissue in abdominal CT scans

    Get PDF
    Master'sMASTER OF SCIENC

    Model-Based Approach for Extracting Femur Contours in X-ray Images

    Get PDF
    Master'sMASTER OF SCIENC

    Quantitative imaging in cardiovascular CT angiography

    Get PDF
    In de afgelopen decennia is computertomografie (CT) een prominente niet-invasieve modaliteit om hart- en vaatziekten te evalueren geworden. Dit proefschrift heeft als doel de rol van CT in de therapeutische behandeling van coronaire hartziekte (CAD) en klepaandoeningen te onderzoeken.De relatie tussen kransslagadergeometrie (statisch en dynamisch) en aanwezigheid en omvang van CAD met CT werd onderzocht. De resultaten suggereren dat de statische geometrie van de kransslagader significant gerelateerd is aan de aanwezigheid van plaque en stenose. Er was echter geen verband tussen dynamische verandering van de coronaire arterie-geometrie en de ernst van CAD. Een algoritme om de invloed van intraluminair contrastmiddel op niet-verkalkte atherosclerotische plaque Hounsfield-Unit-waarden te corrigeren werd gepresenteerd en gevalideerd met behulp van fantomen.Diagnose en operatieplanning kunnen cruciale gevolgen hebben voor de klinische uitkomst van chirurgische ingrepen. In dit proefschrift wordt beschreven dat halfautomatische softwareprogramma’s het kwantificeren van het aortaklepgebied betere reproduceerbare resultaten toonden in vergelijking met handmatige metingen, en vergelijkbare resultaten met de huidige gouden standaard, de echocardiografie. Een systematische review over het dynamische gedrag van de aorta-annulus toont aan dat de vorm van de aorta-annulus tijdens de hartcyclus verandert, wat impliceert dat er bij het bepalen van een prothese rekening moet worden gehouden met meerdere fasen. Een andere review beschrijft het gebruik van 3D-printen in de chirurgische planning samen met andere toepassingen voor de behandeling van hartklepaandoeningen.CT is de belangrijkste beeldvormingsmodaliteit in deze onderzoeken, die gericht waren op de therapeutische behandeling van hart- en vaatziekten, van vroege risicobepaling tot diagnose en chirurgische planning.In the recent decades computed tomography (CT) has emerged as a dominant non-invasive modality to evaluate cardiovascular diseases. This thesis aimed to explore the role of CT in the therapeutic management of coronary artery disease (CAD) and valvular diseases.The relationship between both static and dynamic coronary artery geometry and presence and extent of CAD using CT was investigated. The results suggest that the static coronary artery geometry is significantly related to presence of plaque and significant stenosis. However, there were no such relationship between dynamic change of coronary artery geometry and severity of CAD. As part of this thesis an algorithm to correct the influence of lumen contrast enhancement on non-calcified atherosclerotic plaque Hounsfield-Unit values was presented. The algorithm was validated using phantoms. The diagnosis and surgical planning may have crucial impact on clinical outcome. Semi-automatic software for aortic valve area quantification presented in this thesis was proven to be more repeatable and similar to gold standard echocardiography in comparison to manual measurements. The systematic review regarding the dynamic behavior of aortic annulus revealed that aortic annulus geometry changes throughout the cardiac cycle which implies that multiple phases should be taken into account for prosthesis sizing. Another review in this thesis discusses the use of 3D printing in the surgical planning along with other applications for the treatment of valvular diseases.CT is the main imaging modality in these studies which were focused on the therapeutic management of cardiovascular diseases from early risk determination to diagnosis and surgical planning

    Medical image segmentation using edge-based active contours.

    Get PDF
    The main purpose of image segmentation using active contours is to extract the object of interest in images based on textural or boundary information. Active contour methods have been widely used in image segmentation applications due to their good boundary detection accuracy. In the context of medical image segmentation, weak edges and inhomogeneities remain important issues that may limit the accuracy of any segmentation method formulated using active contour models. This thesis develops new methods for segmentation of medical images based on the active contour models. Three different approaches are pursued: The first chapter proposes a novel external force that integrates gradient vector flow (GVF) field forces and balloon forces based on a weighting factor computed according to local image features. The proposed external force reduces noise sensitivity, improves performance over weak edges and allows initialization with a single manually selected point. The next chapter proposes a level set method that is based on the minimization of an objective energy functional whose energy terms are weighted according to their relative importance in detecting boundaries. This relative importance is computed based on local edge features collected from the adjacent region inside and outside of the evolving contour. The local edge features employed are the edge intensity and the degree of alignment between the images gradient vector flow field and the evolving contours normal. Finally, chapter 5 presents a framework that is capable of segmenting the cytoplasm of each individual cell and can address the problem of segmenting overlapping cervical cells using edge-based active contours. The main goal of our methodology is to provide significantly fully segmented cells with high accuracy segmentation results. All of the proposed methods are then evaluated for segmentation of various regions in real MRI and CT slices, X-ray images and cervical cell images. Evaluation results show that the proposed method leads to more accurate boundary detection results than other edge-based active contour methods (snake and level-set), particularly around weak edges

    Integrating Contour-Coupling with Spatio-Temporal Models in Multi-Dimensional Cardiac Image Segmentation

    Get PDF
    corecore