2,478 research outputs found

    elastography in primary open-angle glaucoma

    Get PDF
    Objective: The aim of this study was to compare sonoelastographic findings in the retina-choroid-sclera (RCS) complex and vitreous in glaucomatous and healthy eyes.Methods: For this cross-sectional comparative study, 20 patients with primary open-angle glaucoma and 20 healthy volunteers were recruited. Ultrasound elastography measurements were taken with a sonographic scanner of the RCS complex, anterior vitreous (AV), posterior vitreous (PV), retrobulbar fat tissue (RFT), optic disc (OD) and optic nerve (ON) in each eye.Results: The elasticity index of the RCS complex, RFT, OD, ON, AV and PV was similar in both groups (p > 0.05), although the AV/PV strain ratio in the group of patients with glaucoma was significantly higher (p = 0.04).Conclusion: Glaucoma increases the AV/PV strain ratio. In providing reproducible and consistent values, the real-time elastography (RTE) technique may be helpful in elucidating the mechanisms of glaucoma in some aspects.Advances in knowledge: This study can help to evaluate the elasticity of the RCS complex and vitreous in glaucomatous eyes with RTE

    Full OCT anterior segment biometry: An application in cataract surgery

    Get PDF
    In vivo three-dimensional (3-D) anterior segment biometry before and after cataract surgery was analyzed by using custom highresolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT). The system was provided with custom algorithms for denoising, segmentation, full distortion correction (fan and optical) and merging of the anterior segment volumes (cornea, iris, and crystalline lens or IOL), to provide fully quantitative data of the anterior segment of the eye. The method was tested on an in vitro artificial eye with known surfaces geometry at different orientations and demonstrated on an aging cataract patient in vivo. Biometric parameters CCT, ACD/ILP, CLT/ILT Tilt and decentration are retrieved with a very high degree of accuracy. IOL was placed 400 οm behind the natural crystalline lens, The IOL was aligned with a similar orientation of the natural lens (2.47 deg superiorly), but slightly lower amounts (0.77 deg superiorly). The IOL was decentered superiorly (0.39 mm) and nasally (0.26 mm). © 2013 Optical Society of America.This study has been funded by Spanish Government Grant FIS2011-25637 and European Research Council Grant ERC-2011-AdG-294099 to S. Marcos.Peer Reviewe

    Muscleblind-like 3 deficit results in a spectrum of age-associated pathologies observed in myotonic dystrophy.

    Get PDF
    Myotonic dystrophy type I (DM1) exhibits distinctive disease specific phenotypes and the accelerated onset of a spectrum of age-associated pathologies. In DM1, dominant effects of expanded CUG repeats result in part from the inactivation of the muscleblind-like (MBNL) proteins. To test the role of MBNL3, we deleted Mbnl3 exon 2 (Mbnl3(ΔE2)) in mice and examined the onset of age-associated diseases over 4 to 13 months of age. Accelerated onset of glucose intolerance with elevated insulin levels, cardiac systole deficits, left ventricle hypertrophy, a predictor of a later onset of heart failure and the development of subcapsular and cortical cataracts is observed in Mbnl3(ΔE2) mice. Retention of embryonic splice isoforms in adult organs, a prominent defect in DM1, is not observed in multiple RNAs including the Insulin Receptor (Insr), Cardiac Troponin T (Tnnt2), Lim Domain Binding 3 (Ldb3) RNAs in Mbnl3(ΔE2) mice. Although rare DM1-like splice errors underlying the observed phenotypes cannot be excluded, our data in conjunction with the reported absence of alternative splice errors in embryonic muscles of a similar Mbnl3(ΔE2) mouse by RNA-seq studies, suggest that mechanisms distinct from the adult retention of embryonic splice patterns may make important contributions to the onset of age-associated pathologies in DM1

    Confocal and Histological Features After Poly(Ethylene Glycol) Diacrylate Corneal Inlay Implantation

    Get PDF
    Purpose: To evaluate the in vivo biocompatibility of photopolymerized poly(ethylene glycol) diacrylate (PEGDA) intrastromal inlays in rabbit corneas. Methods: Sixty-three eyes of 42 New Zealand rabbits were included. Manual intrastromal pockets were dissected in 42 eyes. PEGDA inlays were obtained using a specifically designed photomask and were inserted in the intrastromal pocket of 21 eyes (inlay group); the remaining 21 right eyes did not receive any implant (pocket-only group). Twenty-one eyes with no intervention were used as controls. In vivo confocal microscopy (IVCM) was performed at every visit. After 2 months, rabbits were sacrificed and corneas removed for histological analysis. Results: Corneas remained clear in all but two animals, and five cases of corneal neovascularization were seen (P = 0.2). Inlays remained stable without evidence of lateral or anterior migration, and no other complications were observed. No changes in anterior and posterior keratocyte density (P = 0.3 and P = 0.1, respectively) or endothelial cell density (P = 0.23) were observed between groups during the study time by IVCM. On pathology samples, thinning of the epithelium over the inlay area and epithelial hyperplasia over the edges were observed. A polygonal empty space with no evidence of PEGDA hydrogel within the midstroma was seen in the inlay group. Keratocytes were normal in shape and number in the vicinity of the PEGDA implant area. Conclusions: Photopolymerized PEGDA intrastromal inlays have shown relatively good safety and stability in rabbit corneas. Inlays were biostable in the corneal environment and remained transparent during follow up. Translational Relevance: The investigated PEGDA is promising for the development of biocompatible intrastromal implants.Supported in part by the Spanish Ministry of Science and Education through Apply Research, grant MAT2006-13708-CO2-01. The authors alone are responsible for the content and writing of the paper. Disclosure: A. Bidaguren, None; J. Mendicute, None; I. Madarieta, Tecnalia (E); N. Garagorri, Tecnalia (E

    Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases

    Get PDF
    Optical coherence tomography (OCT) is a noncontact technology that produces high-resolution cross-sectional images of ocular tissues. Anterior segment OCT (AS-OCT) enables the precise visualization of anterior segment structure; thus, it can be used in various corneal and ocular surface disorders. In this review, the authors will discuss the application of AS-OCT for diagnosis and management of various corneal and ocular surface disorders. Use of AS-OCT for anterior segment surgery and postoperative management will also be discussed. In addition, application of the device for research using human data and animal models will be introduced

    Ex-vivo and In-vivo Characterization of Human Accommodation

    Get PDF
    A completely satisfying approach to restoring accommodation still needs to be developed. Besides, there are considerable discrepancies between objective and subjective trials to evaluate the therapeutic success. A substantial biomechanical understanding of all structures and processes involved in accommodation as well as presbyopia are needed to develop promising new strategies. This contribution focuses on developing advanced imaging techniques to create a basic understanding of accommodation and presbyopia and to evaluate existing concepts for restoring accommodation. Besides, the emphasis is also on replacing stiff presbyopic lenses by a material that imitates the young crystalline lens

    Evaluation of axial length measurements obtained using three different techniques- applanation A-scan, immersion A-scan and optical biometer

    Get PDF
    Background: To compare measurements of axial length obtained with manual A-scan, immersion A-scan and optical biometer and assess the accuracy of different techniques of intraocular lens power calculation. Methods: This was a prospective randomized study done in 90 patients over a period extending from November 2019 to October 2020 in the upgraded department of ophthalmology, Government Medical College Jammu. Intraocular lens power was calculated by measuring axial length by three different techniques and further the accuracy of the axial length values obtained were compared. Results: In this study, mean axial length measured by applanation A-scan was 22.86±0.85 mm which ranged from 20.99-24.6 mm and axial length measured by immersion technique ranged from 21.5-24.9 mm with a mean AL of 22.92±0.85 mm. AL measured by non-contact method ranged from 20-25.08 mm with a mean AL of 23.1±0.93 mm. There was a statistically significant difference between all the three techniques regarding the measured AL (p=0.0004). Conclusions: This study concludes that the optical biometry has greater accuracy than ultrasound biometry including applanation and immersion A-scan
    corecore