8 research outputs found

    Exclusive Papers of the Editorial Board Members (EBMs) of the Materials Chemistry Section of Molecules

    Get PDF
    The book is intended to collect the recent contributions (either research or review papers) to the development of the “Materials Chemistry” research fields by the Editorial Board Members of the Materials Chemistry Section of Molecules. The aim is to present the recent progress in the fields and to highlight the key role of Materials Chemistry in a multidisciplinary research context

    Sewage sludge heavy metal analysis and agricultural prospects for Fiji

    Get PDF
    Insoluble residues produced in Waste Water Treatment Plants (WWTP) as by products are known as sewage sludge (SS). Land application of SS, particularly in agricultural lands, is becoming an alternative disposal method in Fiji. However, currently there is no legislative framework governing its use. SS together with its high nutrient and organic matter contents, constitutes some undesired pollutants such as heavy metals, which may limit its extensive use. The focus of this study therefore was to determine the total concentrations of Pb, Zn, Cd, Cu, Cr, Ni and Mn in the SS produced at the Kinoya WWTP (Fiji) and in the non-fertile soil amended with the SS at 20, 40, 60, 80% application rates and in the control (100% Soil). The bioavailable heavy metals were also determined as it depicts the true extent of metal contamination. The treatment mixtures were then used to cultivate cabbage plants in which the total heavy metal uptake was investigated. Total Zn (695.6 mg/kg) was present in the highest amounts in the 100% SS (control), followed by Pb (370.9 mg/kg), Mn (35.0 mg/kg), Cu (65.5 mg/kg), Cr (20.5 mg/kg) and finally Cd (13.5 mg/kg) and hence a similar trend was seen in all treatment mixtures. The potential mobility of sludgeborne heavy metals can be classified as Ni > Cu > Cd > Zn > Mn > Cr > Pb. Total metal uptake in plant leaves and stems showed only the bioavailable metals Cu, Cd, Zn and Mn, with maximum uptake occurring in the leaves. Ni, despite being highly mobile was not detected, due to minute concentrations in the SS treatments. Optimum growth occurred in the 20 and 40% SS treatments. However maximum Cu and Mn uptake occurred in the 40% SS treatment thereby making the 20% treatment the most feasible. Furthermore the total and bioavailable metal concentrations observed were within the safe and permitted limits of the EEC and USEPA legislations

    Microscopy Conference 2017 (MC 2017) - Proceedings

    Get PDF
    Das Dokument enthält die Kurzfassungen der Beiträge aller Teilnehmer an der Mikroskopiekonferenz "MC 2017", die vom 21. bis 25.08.2017, in Lausanne stattfand

    Microscopy Conference 2017 (MC 2017) - Proceedings

    Get PDF
    Das Dokument enthält die Kurzfassungen der Beiträge aller Teilnehmer an der Mikroskopiekonferenz "MC 2017", die vom 21. bis 25.08.2017, in Lausanne stattfand

    Environmental Molecular Sciences Laboratory 2007 Annual Report

    Full text link

    Ultrafast and Energy-saving Synthesis of Nitrogen and Chlorine Co-doped Carbon Nanodots via Neutralization Heat for Selective Detection of Cr(VI) in Aqueous Phase

    No full text
    In this work, it is presented for the first time that nitrogen and chlorine co-doped carbon nanodots (N,Cl-CDs) were synthesized by simply mixing glucose, concentrated hydrochloric acid (HCl), and 1,2-ethylenediamine (EDA). No external heat was employed; the neutralization reaction served as the heat source. The glucose served as the carbon source while EDA and HCl were the N and Cl dopants, respectively. The fluorescence of N,Cl-CDs was adequately quenched by hexavalent chromium Cr(VI) based on a combination of dynamic quenching and inner filter effect (IFE). Accordingly, an efficient N,Cl-CDs-based fluorescence probe was established for sensitive and selective detection of Cr(VI). The proposed fluorescence sensor provides a linear recognition range for Cr(VI) determination from 3 to 40 µM with a limit of detection (LOD) of 0.28 µM (14.6 µg/L). The proposed fluorescence method was successfully utilized to detect Cr(VI) in different water samples with satisfactory results. The spike recoveries vary from 97.01% to 103.89% with relative standard deviations (RSDs) of less than 0.82%. This work highlights the development of a simple, ultrafast, and energy-saving one-step synthetic route to fabricate N,Cl-CDs for highly selective and sensitive detection of Cr(VI) in real water samples. It is anticipated that the proposed fluorescence method could be further explored and widely used for Cr(VI) detection in the environmental industry

    Ultrafast and Energy-saving Synthesis of Nitrogen and Chlorine Co-doped Carbon Nanodots via Neutralization Heat for Selective Detection of Cr(VI) in Aqueous Phase

    No full text
    In this work, it is presented for the first time that nitrogen and chlorine co-doped carbon nanodots (N,Cl-CDs) were synthesized by simply mixing glucose, concentrated hydrochloric acid (HCl), and 1,2-ethylenediamine (EDA). No external heat was employed; the neutralization reaction served as the heat source. The glucose served as the carbon source while EDA and HCl were the N and Cl dopants, respectively. The fluorescence of N,Cl-CDs was adequately quenched by hexavalent chromium Cr(VI) based on a combination of dynamic quenching and inner filter effect (IFE). Accordingly, an efficient N,Cl-CDs-based fluorescence probe was established for sensitive and selective detection of Cr(VI). The proposed fluorescence sensor provides a linear recognition range for Cr(VI) determination from 3 to 40 µM with a limit of detection (LOD) of 0.28 µM (14.6 µg/L). The proposed fluorescence method was successfully utilized to detect Cr(VI) in different water samples with satisfactory results. The spike recoveries vary from 97.01% to 103.89% with relative standard deviations (RSDs) of less than 0.82%. This work highlights the development of a simple, ultrafast, and energy-saving one-step synthetic route to fabricate N,Cl-CDs for highly selective and sensitive detection of Cr(VI) in real water samples. It is anticipated that the proposed fluorescence method could be further explored and widely used for Cr(VI) detection in the environmental industry
    corecore