311 research outputs found
Semi-automatic algorithm for construction of the left ventricular area variation curve over a complete cardiac cycle
<p>Abstract</p> <p>Background</p> <p>Two-dimensional echocardiography (2D-echo) allows the evaluation of cardiac structures and their movements. A wide range of clinical diagnoses are based on the performance of the left ventricle. The evaluation of myocardial function is typically performed by manual segmentation of the ventricular cavity in a series of dynamic images. This process is laborious and operator dependent. The automatic segmentation of the left ventricle in 4-chamber long-axis images during diastole is troublesome, because of the opening of the mitral valve.</p> <p>Methods</p> <p>This work presents a method for segmentation of the left ventricle in dynamic 2D-echo 4-chamber long-axis images over the complete cardiac cycle. The proposed algorithm is based on classic image processing techniques, including time-averaging and wavelet-based denoising, edge enhancement filtering, morphological operations, homotopy modification, and watershed segmentation. The proposed method is semi-automatic, requiring a single user intervention for identification of the position of the mitral valve in the first temporal frame of the video sequence. Image segmentation is performed on a set of dynamic 2D-echo images collected from an examination covering two consecutive cardiac cycles.</p> <p>Results</p> <p>The proposed method is demonstrated and evaluated on twelve healthy volunteers. The results are quantitatively evaluated using four different metrics, in a comparison with contours manually segmented by a specialist, and with four alternative methods from the literature. The method's intra- and inter-operator variabilities are also evaluated.</p> <p>Conclusions</p> <p>The proposed method allows the automatic construction of the area variation curve of the left ventricle corresponding to a complete cardiac cycle. This may potentially be used for the identification of several clinical parameters, including the area variation fraction. This parameter could potentially be used for evaluating the global systolic function of the left ventricle.</p
Recommended from our members
Cardiac Motion Analysis Based on Optical Flow on Real-Time Three-Dimensional Ultrasound Data
With relatively high frame rates and the ability to acquire volume data sets with a stationary transducer, 3D ultrasound systems, based on matrix phased array transducers, provide valuable three-dimensional information, from which quantitative measures of cardiac function can be extracted. Such analyses require segmentation and visual tracking of the left ventricular endocardial border. Due to the large size of the volumetric data sets, manual tracing of the endocardial border is tedious and impractical for clinical applications. Therefore the development of automatic methods for tracking three-dimensional endocardial motion is essential. In this study, we evaluate a four-dimensional optical flow motion tracking algorithm to determine its capability to follow the endocardial border in three dimensional ultrasound data through time. The four-dimensional optical flow method was implemented using three-dimensional correlation. We tested the algorithm on an experimental open-chest dog data set and a clinical data set acquired with a Philips' iE33 three-dimensional ultrasound machine. Initialized with left ventricular endocardial data points obtained from manual tracing at end-diastole, the algorithm automatically tracked these points frame by frame through the whole cardiac cycle. Finite element surfaces were fitted through the data points obtained by both optical flow tracking and manual tracing by an experienced observer for quantitative comparison of the results. Parameterization of the finite element surfaces was performed and maps displaying relative differences between the manual and semi-automatic methods were compared. The results showed good consistency with less than 10% difference between manual tracing and optical flow estimation on 73% of the entire surface. In addition, the optical flow motion tracking algorithm greatly reduced processing time (about 94% reduction compared to human involvement per cardiac cycle) for analyzing cardiac function in three-dimensional ultrasound data sets. A displacement field was computed from the optical flow output, and a framework for computation of dynamic cardiac information is introduced. The method was applied to a clinical data set from a heart transplant patient and dynamic measurements agreed with known physiology as well as experimental results
Deep Learning in Cardiology
The medical field is creating large amount of data that physicians are unable
to decipher and use efficiently. Moreover, rule-based expert systems are
inefficient in solving complicated medical tasks or for creating insights using
big data. Deep learning has emerged as a more accurate and effective technology
in a wide range of medical problems such as diagnosis, prediction and
intervention. Deep learning is a representation learning method that consists
of layers that transform the data non-linearly, thus, revealing hierarchical
relationships and structures. In this review we survey deep learning
application papers that use structured data, signal and imaging modalities from
cardiology. We discuss the advantages and limitations of applying deep learning
in cardiology that also apply in medicine in general, while proposing certain
directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table
Echo from noise: synthetic ultrasound image generation using diffusion models for real image segmentation
We propose a novel pipeline for the generation of synthetic ultrasound images
via Denoising Diffusion Probabilistic Models (DDPMs) guided by cardiac semantic
label maps. We show that these synthetic images can serve as a viable
substitute for real data in the training of deep-learning models for ultrasound
image analysis tasks such as cardiac segmentation. To demonstrate the
effectiveness of this approach, we generated synthetic 2D echocardiograms and
trained a neural network for segmenting the left ventricle and left atrium. The
performance of the network trained on exclusively synthetic images was
evaluated on an unseen dataset of real images and yielded mean Dice scores of
88.6 , 91.9 , 85.2 \% for left ventricular
endocardium, epicardium and left atrial segmentation respectively. This
represents a relative increase of , and \% in Dice scores
compared to the previous state-of-the-art. The proposed pipeline has potential
for application to a wide range of other tasks across various medical imaging
modalities
A Survey on Deep Learning in Medical Image Analysis
Deep learning algorithms, in particular convolutional networks, have rapidly
become a methodology of choice for analyzing medical images. This paper reviews
the major deep learning concepts pertinent to medical image analysis and
summarizes over 300 contributions to the field, most of which appeared in the
last year. We survey the use of deep learning for image classification, object
detection, segmentation, registration, and other tasks and provide concise
overviews of studies per application area. Open challenges and directions for
future research are discussed.Comment: Revised survey includes expanded discussion section and reworked
introductory section on common deep architectures. Added missed papers from
before Feb 1st 201
Echocardiography
The book "Echocardiography - New Techniques" brings worldwide contributions from highly acclaimed clinical and imaging science investigators, and representatives from academic medical centers. Each chapter is designed and written to be accessible to those with a basic knowledge of echocardiography. Additionally, the chapters are meant to be stimulating and educational to the experts and investigators in the field of echocardiography. This book is aimed primarily at cardiology fellows on their basic echocardiography rotation, fellows in general internal medicine, radiology and emergency medicine, and experts in the arena of echocardiography. Over the last few decades, the rate of technological advancements has developed dramatically, resulting in new techniques and improved echocardiographic imaging. The authors of this book focused on presenting the most advanced techniques useful in today's research and in daily clinical practice. These advanced techniques are utilized in the detection of different cardiac pathologies in patients, in contributing to their clinical decision, as well as follow-up and outcome predictions. In addition to the advanced techniques covered, this book expounds upon several special pathologies with respect to the functions of echocardiography
Semi-supervised segmentation of ultrasound images based on patch representation and continuous min cut.
Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature
Left-ventricular epi- and endocardium extraction from 3D ultrasound images using an automatically constructed 3D ASM
© 2014 Taylor & Francis.In this paper, we propose an automatic method for constructing an active shape model (ASM) to segment the complete cardiac left ventricle in 3D ultrasound (3DUS) images, which avoids costly manual landmarking. The automatic construction of the ASM has already been addressed in the literature; however, the direct application of these methods to 3DUS is hampered by a high level of noise and artefacts. Therefore, we propose to construct the ASM by fusing the multidetector computed tomography data, to learn the shape, with the artificially generated 3DUS, in order to learn the neighbourhood of the boundaries. Our artificial images were generated by two approaches: a faster one that does not take into account the geometry of the transducer, and a more comprehensive one, implemented in Field II toolbox. The segmentation accuracy of our ASM was evaluated on 20 patients with left-ventricular asynchrony, demonstrating plausibility of the approach
- …