83 research outputs found

    Wearable and Nearable Biosensors and Systems for Healthcare

    Get PDF
    Biosensors and systems in the form of wearables and “nearables” (i.e., everyday sensorized objects with transmitting capabilities such as smartphones) are rapidly evolving for use in healthcare. Unlike conventional approaches, these technologies can enable seamless or on-demand physiological monitoring, anytime and anywhere. Such monitoring can help transform healthcare from the current reactive, one-size-fits-all, hospital-centered approach into a future proactive, personalized, decentralized structure. Wearable and nearable biosensors and systems have been made possible through integrated innovations in sensor design, electronics, data transmission, power management, and signal processing. Although much progress has been made in this field, many open challenges for the scientific community remain, especially for those applications requiring high accuracy. This book contains the 12 papers that constituted a recent Special Issue of Sensors sharing the same title. The aim of the initiative was to provide a collection of state-of-the-art investigations on wearables and nearables, in order to stimulate technological advances and the use of the technology to benefit healthcare. The topics covered by the book offer both depth and breadth pertaining to wearable and nearable technology. They include new biosensors and data transmission techniques, studies on accelerometers, signal processing, and cardiovascular monitoring, clinical applications, and validation of commercial devices

    An optimization study of estimating blood pressure models based on pulse arrival time for continuous monitoring

    Get PDF
    Continuous blood pressure (BP) monitoring has a significant meaning for the prevention and early diagnosis of cardiovascular disease. However, under different calibration methods, it is difficult to determine which model is better for estimating BP. This study was firstly designed to reveal a better BP estimation model by evaluating and optimizing different BP models under a justified and uniform criterion, i.e., the advanced point-to-point pairing method (PTP). Here, the physical trial in this study caused the BP increase largely. In addition, the PPG and ECG signals were collected while the cuff bps were measured for each subject. The validation was conducted on four popular vascular elasticity (VE) models (MK-EE, L-MK, MK-BH, and dMK-BH) and one representative elastic tube (ET) model, i.e., M-M. The results revealed that the VE models except for L-MK outperformed the ET model. The linear L-MK as a VE model had the largest estimated error, and the nonlinear M-M model had a weaker correlation between the estimated BP and the cuff BP than MK-EE, MK-BH, and dMK-BH models. Further, in contrast to L-MK, the dMK-BH model had the strongest correlation and the smallest difference between the estimated BP and the cuff BP including systolic blood pressure (SBP) and diastolic blood pressure (DBP) than others. In this study, the simple MK-EE model showed the best similarity to the dMK-BH model. There were no significant changes between MK-EE and dMK-BH models. These findings indicated that the nonlinear MK-EE model with low estimated error and simple mathematical expression was a good choice for application in wearable sensor devices for cuff-less BP monitoring compared to others

    Quantifying the effects of blood pressure changes on ballistocardiogram signals

    Get PDF
    Quantifying the effects of blood pressure (BP) changes on the ballistocardiogram (BCG) signal shape and features can potentially improve the understanding of this mechanical modality of cardiovascular sensing. BCG, a measure of body movements caused by ejection of blood into the vasculature, has recently re-emerged as a promising method for trending cardiac output and myocardial contractility. Although recent research has shown that the BCG waveform has the potential to be used as a viable proximal timing reference for measuring pulse transit time (PTT) and indirectly BP, it has not been deeply explored for direct estimation of BP. In this paper, we posit that the BCG signal contains features corresponding to changes in BP. To further investigate this hypothesis, BCG waveforms were measured using a modified-weighing scale from 14 subjects performing an isometric handgrip challenge in a seated position. The energy in the latter half of the BCG heartbeat was estimated using polynomial fitting and interpolation methods. The results indicate that an increase in mean arterial pressure (MAP) or a decrease in PTT manifests itself in the form of high amplitude oscillations following the main peak (J-peak) in a BCG heartbeat, thus elucidating the mechanisms behind these oscillations and also potentially improving the breadth of data that can be sensed using BCG signals. © 2017 IEEE

    Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension

    Get PDF
    Elevated blood pressure (BP) is a major cause of death, yet hypertension commonly goes undetected. Owing to its nature, it is typically asymptomatic until later in its progression when the vessel or organ structure has already been compromised. Therefore, noninvasive and continuous BP measurement methods are needed to ensure appropriate diagnosis and early management before hypertension leads to irreversible complications. Photoplethysmography (PPG) is a noninvasive technology with waveform morphologies similar to that of arterial BP waveforms, therefore attracting interest regarding its usability in BP estimation. In recent years, wearable devices incorporating PPG sensors have been proposed to improve the early diagnosis and management of hypertension. Additionally, the need for improved accuracy and convenience has led to the development of devices that incorporate multiple different biosignals with PPG. Through the addition of modalities such as an electrocardiogram, a final measure of the pulse wave velocity is derived, which has been proved to be inversely correlated to BP and to yield accurate estimations. This paper reviews and summarizes recent studies within the period 2010-2019 that combined PPG with other biosignals and offers perspectives on the strengths and weaknesses of current developments to guide future advancements in BP measurement. Our literature review reveals promising measurement accuracies and we comment on the effective combinations of modalities and success of this technology

    Error Prevention in Sensors and Sensor Systems

    Get PDF
    Achievements in all fields of engineering and fabrication methods have led towards optimization and integration of multiple sensing devices into a concise system. These advances have caused significant innovation in various commercial, industrial, and research efforts. Integrations of subsystems have important applications for sensor systems in particular. The need for reporting and real time awareness of a device’s condition and surroundings have led to sensor systems being implemented in a wide variety of fields. From environmental sensors for agriculture, to object characterization and biomedical sensing, the application for sensor systems has impacted all modern facets of innovation. With these innovations, however, additional sources of errors can occur, that can cause new but exciting challenges for such integrated devices. Such challenges range from error correction and accuracy to power optimization. Researchers have invested significant time and effort to improve the applicability and accuracy of sensors and sensor systems. Efforts to reduce inherent and external noise of sensors can range from hardware to software solutions, focusing on signal processing and exploiting the integration of multiple signals and/or sensor types. My research work throughout my career has been focused on deployable and integrated sensor systems. Their integration not only in hardware and components but also in software, machine learning, pattern recognition, and overall signal processing algorithms to aid in error correction and noise tailoring in all their hardware and software components

    Towards fog-driven IoT eHealth:Promises and challenges of IoT in medicine and healthcare

    Get PDF
    Internet of Things (IoT) offers a seamless platform to connect people and objects to one another for enriching and making our lives easier. This vision carries us from compute-based centralized schemes to a more distributed environment offering a vast amount of applications such as smart wearables, smart home, smart mobility, and smart cities. In this paper we discuss applicability of IoT in healthcare and medicine by presenting a holistic architecture of IoT eHealth ecosystem. Healthcare is becoming increasingly difficult to manage due to insufficient and less effective healthcare services to meet the increasing demands of rising aging population with chronic diseases. We propose that this requires a transition from the clinic-centric treatment to patient-centric healthcare where each agent such as hospital, patient, and services are seamlessly connected to each other. This patient-centric IoT eHealth ecosystem needs a multi-layer architecture: (1) device, (2) fog computing and (3) cloud to empower handling of complex data in terms of its variety, speed, and latency. This fog-driven IoT architecture is followed by various case examples of services and applications that are implemented on those layers. Those examples range from mobile health, assisted living, e-medicine, implants, early warning systems, to population monitoring in smart cities. We then finally address the challenges of IoT eHealth such as data management, scalability, regulations, interoperability, device–network–human interfaces, security, and privacy
    • …
    corecore