180 research outputs found

    Myoelectric feature extraction using temporal-spatial descriptors for multifunction prosthetic hand control.

    Full text link
    We tackle the challenging problem of myoelectric prosthesis control with an improved feature extraction algorithm. The proposed algorithm correlates a set of spectral moments and their nonlinearly mapped version across the temporal and spatial domains to form accurate descriptors of muscular activity. The main processing step involves the extraction of the Electromyogram (EMG) signal power spectrum characteristics directly from the time-domain for each analysis window, a step to preserve the computational power required for the construction of spectral features. The subsequent analyses involve computing 1) the correlation between the time-domain descriptors extracted from each analysis window and a nonlinearly mapped version of it across the same EMG channel; representing the temporal evolution of the EMG signals, and 2) the correlation between the descriptors extracted from differences of all possible combinations of channels and a nonlinearly mapped version of them, focusing on how the EMG signals from different channels correlates with each other. The proposed Temporal-Spatial Descriptors (TSDs) are validated on EMG data collected from six transradial amputees performing 11 classes of finger movements. Classification results showed significant reductions (at least 8%) in classification error rates compared to other methods

    Feature Analysis for Classification of Physical Actions using surface EMG Data

    Full text link
    Based on recent health statistics, there are several thousands of people with limb disability and gait disorders that require a medical assistance. A robot assisted rehabilitation therapy can help them recover and return to a normal life. In this scenario, a successful methodology is to use the EMG signal based information to control the support robotics. For this mechanism to function properly, the EMG signal from the muscles has to be sensed and then the biological motor intention has to be decoded and finally the resulting information has to be communicated to the controller of the robot. An accurate detection of the motor intention requires a pattern recognition based categorical identification. Hence in this paper, we propose an improved classification framework by identification of the relevant features that drive the pattern recognition algorithm. Major contributions include a set of modified spectral moment based features and another relevant inter-channel correlation feature that contribute to an improved classification performance. Next, we conducted a sensitivity analysis of the classification algorithm to different EMG channels. Finally, the classifier performance is compared to that of the other state-of the art algorithm

    Reduction of Limb Position Invariant of SEMG Signals for Improved Prosthetic Control using Spectrogram

    Get PDF
    Prostheses are artificial devices that replace a missing body part, which might be lost through injury, infection, or a condition present at birth. It is proposed to re-establish the normal functions of the missing body part and can be made by hand or with a computer-aided design. As per the World Health Organization, around 160,000 individuals in Malaysia are required to use prostheses. One of the elements that influence the current prosthesis control is that the variety in the limb position and normal use results in different electromyogram (EMG) signals with the same movement at various positions. Consequently, the objective of this study is to ensure that amputees can control their prosthetics in an exact manner regardless of their hand movement and limb position. The raw EMG signals are taken from eight different hand movements’ classes at five different limb positions and each of these hand movements has seven electrodes attach to it. This paper utilizes time-frequency distribution which is spectrogram to extract the EMG feature and six SVM classification learners; linear, quadratic, cubic, fine Gaussian, medium Gaussian, and coarse Gaussian were compared to find the most reasonable one for this application. The analysis performance is then verified based on classification accuracy. From the results, the overall accuracy for the classification is 65% (linear), 87.5% (quadratic) and 97.5% (cubic), 100% (fine Gaussian), 70% (medium Gaussian, and 45% (coarse Gaussian), respectively. It is believed that the study could fill in as knowledge to improve conventional prosthetic control strategies

    Real-time EMG based pattern recognition control for hand prostheses : a review on existing methods, challenges and future implementation

    Get PDF
    Upper limb amputation is a condition that significantly restricts the amputees from performing their daily activities. The myoelectric prosthesis, using signals from residual stump muscles, is aimed at restoring the function of such lost limbs seamlessly. Unfortunately, the acquisition and use of such myosignals are cumbersome and complicated. Furthermore, once acquired, it usually requires heavy computational power to turn it into a user control signal. Its transition to a practical prosthesis solution is still being challenged by various factors particularly those related to the fact that each amputee has different mobility, muscle contraction forces, limb positional variations and electrode placements. Thus, a solution that can adapt or otherwise tailor itself to each individual is required for maximum utility across amputees. Modified machine learning schemes for pattern recognition have the potential to significantly reduce the factors (movement of users and contraction of the muscle) affecting the traditional electromyography (EMG)-pattern recognition methods. Although recent developments of intelligent pattern recognition techniques could discriminate multiple degrees of freedom with high-level accuracy, their efficiency level was less accessible and revealed in real-world (amputee) applications. This review paper examined the suitability of upper limb prosthesis (ULP) inventions in the healthcare sector from their technical control perspective. More focus was given to the review of real-world applications and the use of pattern recognition control on amputees. We first reviewed the overall structure of pattern recognition schemes for myo-control prosthetic systems and then discussed their real-time use on amputee upper limbs. Finally, we concluded the paper with a discussion of the existing challenges and future research recommendations

    Review on EMG Acquisition and Classification Techniques: Towards Zero Retraining in the Influence of User and Arm Position Independence

    Get PDF
    The surface electromyogram (EMG) is widely studied and applied in machine control. Recent methods of classifying hand gestures reported classification rates of over 95%. However, the majority of the studies made were performed on a single user, focusing solely on the gesture classification. These studies are restrictive in practical sense: either focusing on just gestures, multi-user compatibility, or rotation independence. The variations in EMG signals due to these conditions present a challenge to the practical application of EMG devices, often requiring repetitious training per application. To the best of our knowledge, there is little comprehensive review of works done in EMG classification in the combined influence of user-independence, rotation and hand exchange. Therefore, in this paper we present a review of works related to the practical issues of EMG with a focus on the EMG placement, and recent acquisition and computing techniques to reduce training. First, we provided an overview of existing electrode placement schemes. Secondly, we compared the techniques and results of single-subject against multi-subject, multi-position settings. As a conclusion, the study of EMG classification in this direction is relatively new. However the results are encouraging and strongly indicate that EMG classification in a broad range of people and tolerance towards arm orientation is possible, and can pave way for more flexible EMG devices

    Towards electrodeless EMG linear envelope signal recording for myo-activated prostheses control

    Get PDF
    After amputation, the residual muscles of the limb may function in a normal way, enabling the electromyogram (EMG) signals recorded from them to be used to drive a replacement limb. These replacement limbs are called myoelectric prosthesis. The prostheses that use EMG have always been the first choice for both clinicians and engineers. Unfortunately, due to the many drawbacks of EMG (e.g. skin preparation, electromagnetic interferences, high sample rate, etc.); researchers have aspired to find suitable alternatives. One proposes the dry-contact, low-cost sensor based on a force-sensitive resistor (FSR) as a valid alternative which instead of detecting electrical events, detects mechanical events of muscle. FSR sensor is placed on the skin through a hard, circular base to sense the muscle contraction and to acquire the signal. Similarly, to reduce the output drift (resistance) caused by FSR edges (creep) and to maintain the FSR sensitivity over a wide input force range, signal conditioning (Voltage output proportional to force) is implemented. This FSR signal acquired using FSR sensor can be used directly to replace the EMG linear envelope (an important control signal in prosthetics applications). To find the best FSR position(s) to replace a single EMG lead, the simultaneous recording of EMG and FSR output is performed. Three FSRs are placed directly over the EMG electrodes, in the middle of the targeted muscle and then the individual (FSR1, FSR2 and FSR3) and combination of FSR (e.g. FSR1+FSR2, FSR2-FSR3) is evaluated. The experiment is performed on a small sample of five volunteer subjects. The result shows a high correlation (up to 0.94) between FSR output and EMG linear envelope. Consequently, the usage of the best FSR sensor position shows the ability of electrode less FSR-LE to proportionally control the prosthesis (3-D claw). Furthermore, FSR can be used to develop a universal programmable muscle signal sensor that can be suitable to control the myo-activated prosthesis

    Current state of digital signal processing in myoelectric interfaces and related applications

    Get PDF
    This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented.Peer reviewe

    Combined influence of forearm orientation and muscular contraction on EMG pattern recognition

    Get PDF
    AbstractThe performance of intelligent electromyogram (EMG)-driven prostheses, functioning as artificial alternatives to missing limbs, is influenced by several dynamic factors including: electrode position shift, varying muscle contraction level, forearm orientation, and limb position. The impact of these factors on EMG pattern recognition has been previously studied in isolation, with the combined effect of these factors being understudied. However, it is likely that a combination of these factors influences the accuracy. We investigated the combined effect of two dynamic factors, namely, forearm orientation and muscle contraction levels, on the generalizability of the EMG pattern recognition. A number of recent time- and frequency-domain EMG features were utilized to study the EMG classification accuracy. Twelve intact-limbed and one bilateral transradial (below-elbow) amputee subject were recruited. They performed six classes of wrist and hand movements at three muscular contraction levels with three forearm orientations (nine conditions). Results indicate that a classifier trained by features that quantify the angle, rather than amplitude, of the muscle activation patterns perform better than other feature sets across different contraction levels and forearm orientations. In addition, a classifier trained with the EMG signals collected at multiple forearm orientations with medium muscular contractions can generalize well and achieve classification accuracies of up to 91%. Furthermore, inclusion of an accelerometer to monitor wrist movement further improved the EMG classification accuracy. The results indicate that the proposed methodology has the potential to improve robustness of myoelectric pattern recognition
    • …
    corecore