169 research outputs found

    Automatic Breast Density Classification on Tomosynthesis Images

    Get PDF
    Breast cancer (BC) is the type of cancer that most greatly affects women globally hence its early detection is essential to guarantee an effective treatment. Although digital mammography (DM) is the main method of BC detection, it has low sensitivity with about 30% of positive cases undetected due to the superimposition of breast tissue when crossed by the X-ray beam. Digital breast tomosynthesis (DBT) does not share this limi tation, allowing the visualization of individual breast slices due to its image acquisition system. Consecutively, DBT was the object of this study as a means of determining one of the main risk factors for BC: breast density (BD). This thesis was aimed at developing an algorithm that, taking advantage of the 3D nature of DBT images, automatically clas sifies them in terms of BD. Thus, a quantitative, objective and reproducible classification was obtained, which will contribute to ascertain the risk of BC. The algorithm was developed in MATLAB and later transferred to a user interface that was compiled into an executable application. Using 350 images from the VICTRE database for the first classification phase – group 1 (ACR1+ACR2) versus group 2 (ACR3+ACR4), the highest AUC value of 0,9797 was obtained. In the classification within groups 1 and 2, the AUC obtained was 0,7461 and 0,6736, respectively. The algorithm attained an accuracy of 82% for these images. Sixteen exams provided by Hospital da Luz were also evaluated, with an overall accuracy of 62,5%. Therefore, a user-friendly and intuitive application was created that prioritizes the use of DBT as a diagnostic method and allows an objective classification of BD. This study is a first step towards preparing medical institutions for the compulsoriness of assessing BD, at a time when BC is still a very present pathology that shortens the lives of thousands of people

    Determinants and influence of mammographic features on breast cancer risk

    Get PDF
    Mammographic density and mammographic microcalcifications are the key imaging features in mammography examination. Mammographic density is known as a strong risk factor for breast cancer and is the radiographic appearance of epithelial and fibrous tissue which appears white on a mammogram. While, the dark part of a mammogram represents the fatty tissue. Mammographic microcalcifications appear as small deposits of calcium and they are one of the earliest sign of breast cancer. Malignant microcalcifications are seen in both in situ and invasive lesions. In this thesis we used the data from the prospective KARMA cohort to study the association between established breast cancer risk factors with mammographic density change over time (Study I), to examine the association between annual mammographic density change and risk of breast cancer (Study II), to investigate the association between established risk factors for breast cancer and microcalcification clusters and their asymmetry (Study III), and finally to elucidate the association between microcalcification clusters, their asymmetry, and risk of overall and subtype specific breast cancer (Study IV). The lifestyle and reproductive factors were assessed using web-based questionnaires. Average mammographic density and total microcalcification clusters were measured using a Computer Aided Detection system (CAD) and the STRATUS method, respectively. In Study I, the average yearly dense area change was -1.0 cm . Body mass index (BMI) and physical activity were statistically associated with density change. Beside age, lean and physically active women had the largest decrease in mammographic density per year. In Study II, overall, 563 women were diagnosed with breast cancer and annual mammographic density change did not seem to influence the risk of breast cancer. Furthermore, density change does not seem to modify the association between baseline density and risk of breast cancer. In Study III, age, mammographic density, genetic factors related to breast cancer, having more children, longer duration of breast-feeding were significantly associated with increased risk of presence of microcalcification clusters. In Study IV, 676 women were diagnosed with breast cancer. Further, women with 33 microcalcification clusters had 2 times higher risk of breast cancer compared to women with no clusters. Microcalcification clusters were associated with both in situ and invasive breast cancer. Finally, during postmenopausal period, microcalcification clusters influence risk of breast cancer to the similar extend as baseline mammographic density. In conclusion, we have identified novel determinants of mammographic density changes and potential predictors of suspicious mammographic microcalcification clusters. Further, our results suggested that annual mammographic density change does not influence breast cancer risk, while presence of suspicious microcalcification clusters was strongly associated with breast cancer risk

    The Role Of Tissue Sound Speed As A Surrogate Marker Of Breast Density

    Get PDF
    Breast density is one of the strongest predictors of breast cancer risk as women with the densest breasts have a three- to five-fold increase in risk compared to women with the least dense breasts. Breast density is currently measured by using mammography, the current gold standard for breast imaging. There are many shortcomings to using mammography to measure breast density, including the use of ionizing radiation. Ultrasound tomography (UST) does not use ionizing radiation and can create tomographic breast sound speed images. These sound speed images are useful because breast density is proportional to sound speed. The purpose of this work was to assess the ability of UST to measure breast density and its ability to measure changes in breast density over short periods of time. A cohort of 251 patients was examined using both UST and mammography. Many different associations were found between the UST density measurement, the volume averaged sound speed, and the mammographic percent density. Additional associations were found between many other UST and mammographic imaging characteristics. UST density was found to correlate with various patient characteristics in a similar manner to mammographic density. Additionally, UST was used to examine the effects of tamoxifen on breast density. Tamoxifen has been shown to reduce mammographic density and breast cancer risk for some women. Preliminary data for 52 patients has shown promising results so far. UST density has decreased for approximately a similar percentage of patients as has been measured for mammographic density. These changes have been measured over short time frames that could not be achieved using mammography. These results show that UST\u27s ability to measure breast density is consistent with mammography, the current standard of care. UST has the potential to become a safe and effective device that can be used to reliably assess breast density and serial changes in breast density

    Breast density:why all the fuss?

    Get PDF

    Improved Diagnostics by Assessing the Micromorphology of Breast Calcifications via X-Ray Dark-Field Radiography

    Get PDF
    Breast microcalcifications play an essential role in the detection and evaluation of early breast cancer in clinical diagnostics. However, in digital mammography, microcalcifications are merely graded with respect to their global appearance within the mammogram, while their interior microstructure remains spatially unresolved and therefore not considered in cancer risk stratification. In this article, we exploit the sub-pixel resolution sensitivity of X-ray dark-field contrast for clinical microcalcification assessment. We demonstrate that the micromorphology, rather than chemical composition of microcalcification clusters (as hypothesised by recent literature), determines their absorption and small-angle scattering characteristics. We show that a quantitative classification of the inherent microstructure as ultra-fine, fine, pleomorphic and coarse textured is possible. Insights underlying the micromorphological nature of breast calcifications are verified by comprehensive high-resolution micro-CT measurements. We test the determined microtexture of microcalcifications as an indicator for malignancy and demonstrate its potential to improve breast cancer diagnosis, by providing a non-invasive tool for sub-resolution microcalcification assessment. Our results indicate that dark-field imaging of microcalcifications may enhance the diagnostic validity of current microcalcification analysis and reduce the number of invasive procedures

    Artificial intelligence in cancer imaging: Clinical challenges and applications

    Get PDF
    Judgement, as one of the core tenets of medicine, relies upon the integration of multilayered data with nuanced decision making. Cancer offers a unique context for medical decisions given not only its variegated forms with evolution of disease but also the need to take into account the individual condition of patients, their ability to receive treatment, and their responses to treatment. Challenges remain in the accurate detection, characterization, and monitoring of cancers despite improved technologies. Radiographic assessment of disease most commonly relies upon visual evaluations, the interpretations of which may be augmented by advanced computational analyses. In particular, artificial intelligence (AI) promises to make great strides in the qualitative interpretation of cancer imaging by expert clinicians, including volumetric delineation of tumors over time, extrapolation of the tumor genotype and biological course from its radiographic phenotype, prediction of clinical outcome, and assessment of the impact of disease and treatment on adjacent organs. AI may automate processes in the initial interpretation of images and shift the clinical workflow of radiographic detection, management decisions on whether or not to administer an intervention, and subsequent observation to a yet to be envisioned paradigm. Here, the authors review the current state of AI as applied to medical imaging of cancer and describe advances in 4 tumor types (lung, brain, breast, and prostate) to illustrate how common clinical problems are being addressed. Although most studies evaluating AI applications in oncology to date have not been vigorously validated for reproducibility and generalizability, the results do highlight increasingly concerted efforts in pushing AI technology to clinical use and to impact future directions in cancer care

    Diagnostic Reference Levels for digital mammography in Australia

    Get PDF
    Aims: In 3 phases, this thesis explores: radiation doses delivered to women during mammography, methods to estimate mean glandular dose (MGD), and the use of mammographic breast density (MBD) in MGD calculations. Firstly, it examines Diagnostic reference levels (DRLs) for digital mammography in Australia, with novel focus on the use of compressed breast thickness (CBT) and detector technologies as a guide when determining patient derived DRLs. Secondly, it analyses the agreement between Organ Dose estimated by different digital mammography units and calculated MGD for clinical data. Thirdly, it explores the novel use of MBD in MGD calculations, suggesting a new dose estimation called the actual glandular dose (AGD), and compares MGD to AGD. Methods: DICOM headers were extracted from 52405 anonymised mammograms using 3rd party software. Exposure and QA information were utilised to calculate MGD using 3 methods. LIBRA software was used to estimate MBD for 31097 mammograms. Median, 75th and 95th percentiles were calculated across MGDs obtained for all included data and according to 9 CBT ranges, average population CBT, and for 3 detector technologies. The significance of the differences, correlations, and agreement between MGDs for different CBT ranges, calculation methods, and different density estimation methods were analysed. Conclusions: This thesis have recommended DRLs for mammography in Australia, it shows that MGD is dependent upon CBT and detector technology, hence DRLs were presented as a table for different CBTs and detectors. The work also shows that Organ Doses reported by vendors vary from that calculated using established methodologies. Data produced also show that the use of MGD calculated using standardised glandularities underestimates dose at lower CBTs compared to AGD by up to 10%, hence, underestimating radiation risk. Finally, AGD was proposed; it considers differences in breast composition for individualised radiation-induced risk assessment

    Mammography Techniques and Review

    Get PDF
    Mammography remains at the backbone of medical tools to examine the human breast. The early detection of breast cancer typically uses adjunct tests to mammogram such as ultrasound, positron emission mammography, electrical impedance, Computer-aided detection systems and others. In the present digital era it is even more important to use the best new techniques and systems available to improve the correct diagnosis and to prevent mortality from breast cancer. The first part of this book deals with the electrical impedance mammographic scheme, ultrasound axillary imaging, position emission mammography and digital mammogram enhancement. A detailed consideration of CBR CAD System and the availability of mammographs in Brazil forms the second part of this book. With the up-to-date papers from world experts, this book will be invaluable to anyone who studies the field of mammography
    • …
    corecore