22 research outputs found

    Nonlinear control schemes for extremum power seeking and torsional vibration mitigation in variable speed wind turbine systems

    Get PDF
    Doctor of PhilosophyDepartment of Electrical and Computer EngineeringDon GruenbacherWarren WhiteThis dissertation presents nonlinear control schemes to improve the productivity and lifespan of doubly fed induction generator (DFIG)-based and permanent magnet generator (PMG)-based variable speed wind turbines. To improve the productivity, a nonlinear adaptive control scheme is developed to maximize power capture. This controller consists of three feedback loops. The first loop controls electrical torque of the generator in order to cancel the nonlinear term of the turbine equation of motion using the feedback linearization concept. The nonlinearity cancelation requires a real-time estimation of aerodynamic torque. This is achieved through a second loop which estimates the ratio of the wind turbine power capture versus the available wind power. A third loop utilizes this estimate to identify the shaft speed at which the wind turbine operates at a greater power output. Contrary to existing techniques in literature, this innovative technique does not require any prior knowledge of the optimum tip speed ratio. The presented technique does not need a dither or perturbation signal to track the optimum shaft speed at the maximum power capture. These features make this technique superior to existing methods. Furthermore, the lifespan of variable speed wind turbines is improved by reducing stress on the wind turbine drivetrain. This is achieved via developing a novel vibration mitigation technique using sliding-mode control theory. The technique measures only generator speed as the input signal and then passes it through a high-pass filter in order to extract the speed variations. The filtered signal and its integral are then passed through identical band-pass filters centered at the dominant natural frequency of the drivetrain. These two signals formulate a sliding surface and consequently a control law to damp the drivetrain torsional stress oscillations caused by electrical and mechanical disturbances. This technique provides a robust mitigation approach compared with existing techniques. These control schemes are verified through holistic models of DFIG- and PMG-based wind turbines. Except for wind turbine aerodynamics, for which an existing simulator is used, the developed models of all components including DFIG, PMG, converters, multi-mass drivetrain, and power line are presented in this dissertation

    Analysis of Dynamic Interactions between Different Drivetrain Components with a Detailed Wind Turbine Model

    Get PDF
    The presented work describes a detailed analysis of the dynamic interactions among mechanical and electrical drivetrain components of a modern wind turbine under the influence of parameter variations, different control mechanisms and transient excitations. For this study, a detailed model of a 2MW wind turbine with a gearbox, a permanent magnet synchronous generator and a full power converter has been developed which considers all relevant characteristics of the mechanical and electrical subsystems. This model includes an accurate representation of the aerodynamics and the mechanical properties of the rotor and the complete mechanical drivetrain. Furthermore, a detailed electrical modelling of the generator, the full scale power converter with discrete switching devices, its filters, the transformer and the grid as well as the control structure is considered. The analysis shows that, considering control measures based on active torsional damping, interactions between mechanical and electrical subsystems can significantly affect the loads and thus the individual lifetime of the components

    SCR-Based Wind Energy Conversion Circuitry and Controls for DC Distributed Wind Farms

    Get PDF
    The current state of art for electrical power generated by wind generators are in alternating current (AC). Wind farms distribute this power as 3-phase AC. There are inherent stability issues with AC power distribution. The grid power transfer capacity is limited by the distance and characteristic impedance of the lines. Furthermore, wind generators have to implement complicated, costly, and inefficient back-to-back converters to generate AC. AC distribution does not offer an easy integration of energy storage. To mitigate drawbacks with AC generation and distribution, direct current (DC) generation and high voltage direct current (HVDC) distribution for the wind farms is proposed. DC power distribution is inherently stable. The generators convert AC power to DC without the use of a back-to-back converter. DC grid offers an easy integration of energy storage. The proposed configuration for the generator is connected to a HVDC bus using a 12 pulse thyristor network, which can apply Maximum Power Point Tracking (MPPT). To properly control the system, several estimators are designed and applied. This includes a firing angle, generator output voltage, and DC current estimators to reduce noise effects. A DSP-based controller is designed and implemented to control the system and provide gate pulses. Performance of the proposed system under faults and drive train torque pulsation are analyzed as well. Additionally, converter paralleling when turbines operate at different electrical power levels are also studied. The proposed new Wind Energy Conversion System (WECS) is described in detail and verified using MATLAB®/ Simulink® simulation and experimental test setup. The proposed solution offers higher reliability, lower conversion power loss, and lower cost. The following is proposed as future work: 1) Study different control methods for controlling the SCR\u27s. 2) Investigate reducing torque pulsations of the PMSG and using the proposed power conversion method for DFIG turbines. 3) Explore options for communication/control between PMSG, circuit protection and grid-tied inverters. 4) Investigate the best possible configuration for DC storage/connection to the HVDC/MVDC bus. 5) Study the filtering needed to improve the DC bus voltage at the generator

    Lithium-Ion Ultracapacitor Energy Storage Integrated with a Variable Speed Wind Turbine for Improved Power Conversion Control

    Get PDF
    The energy of wind has been increasingly used for electric power generation worldwide due to its availability and ecologically sustainability. Utilization of wind energy in modern power systems creates many technical and economical challenges that need to be addressed for successful large scale wind energy integration. Variations in wind velocity result in variations of output power produced by wind turbines. Variable power output becomes a challenge as the amount of output power of the wind turbines integrated into power systems increases. Large power variations cause voltage and frequency deviations from nominal values that may lead to activation of relay protective equipment, which may result in disconnection of the wind turbines from the grid. Particularly community wind power systems, where only one or a few wind turbines supply loads through a weak grid such as distribution network, are sensitive to supply disturbances. While a majority of power produced in modern power systems comes from synchronous generators that have large inertias and whose control systems can compensate for slow power variations in the system, faster power variations at the scale of fraction of a second to the tens of seconds can seriously reduce reliability of power system operation. Energy storage integrated with wind turbines can address this challenge. In this dissertation, lithium-ion ultracapacitors are investigated as a potential solution for filtering power variations at the scale of tens of seconds. Another class of issues related to utilization of wind energy is related to economical operation of wind energy conversion systems. Wind speed variations create large mechanical loads on wind turbine components, which lead to their early failures. One of the most critical components of a wind turbine is a gearbox that mechanically couples turbine rotor and generator. Gearboxes are exposed to large mechanical load variations which lead to their early failures and increased cost of wind turbine operation and maintenance. This dissertation proposes a new critical load reduction strategy that removes mechanical load components that are the most dangerous in terms of harmful effect they have on a gearbox, resulting in more reliable operation of a wind turbine

    Ofshore Wind Park Control Assessment Methodologies to Assure Robustness

    Get PDF

    Investigation into the use of variable speed drives to damp mechanical oscillations

    Get PDF
    Research report to School of Electrical and Information EngineeringAn investigation was conducted into how a variable speed drive can provide a damping torque when mechanical oscillations are present. The modeling of mechanical oscillations via an analogous electrical circuit was performed. Simulation was used to demonstrate how a variable speed drive is able to damp speed oscillations using Direct Torque Control (DTC). Damping of mechanical oscillations is done by means of the variable speed drive providing a damping torque component that is in-phase with the speed deviation. The simulation showed that by applying a small torque component with the speed variation results in torque oscillations being damped by 60% after the initial disturbance. Damping is further improved by applying a torque component equal to the speed variation resulting in the oscillations being damped by 80% when compared to the initial disturbance.MT201

    The Role of Power Electronics in Modern Energy System Integration

    Get PDF

    Grid Connected Doubly Fed Induction Generator Based Wind Turbine under LVRT

    Get PDF
    This project concentrates on the Low Voltage Ride Through (LVRT) capability of Doubly Fed Induction Generator (DFIG) wind turbine. The main attention in the project is, therefore, drawn to the control of the DFIG wind turbine and of its power converter and to the ability to protect itself without disconnection during grid faults. It provides also an overview on the interaction between variable speed DFIG wind turbines and the power system subjected to disturbances, such as short circuit faults. The dynamic model of DFIG wind turbine includes models for both mechanical components as well as for all electrical components, controllers and for the protection device of DFIG necessary during grid faults. The viewpoint of this project is to carry out different simulations to provide insight and understanding of the grid fault impact on both DFIG wind turbines and on the power system itself. The dynamic behavior of DFIG wind turbines during grid faults is simulated and assessed by using a transmission power system generic model developed and delivered by Transmission System Operator in the power system simulation toolbox Digsilent, Matlab/Simulink and PLECS

    Electro-mechanical modelling of tidal arrays

    Get PDF
    The aim of this study is to present, compare and improve the options of power transmission for tidal current arrays. The potential to generate low or zero carbon power from the world’s tides is increasing as technology moves forward. The technically available tidal current energy resource, the resource that can be captured using existing technology, in the United Kingdom can supply a significant amount of the UK electricity demand. Even though tidal current devices have similarities to offshore wind turbines in many aspects, a number of characteristics differentiate the approach needed regarding power transmission and drive-train design. Some of these characteristics are: predictable direction and speed of the tidal current, predetermined available area in a tidal channel, less swept area due higher density of water, continuous underwater operation and smaller distances to shore. This thesis is based on the hypothesis that tidal current energy can be harnessed using today’s technology in an efficient manner. Technology progression never stops and as new materials and methods become available the cost of utilising tidal current energy will drop in the years to come. However, the research question that has to be asked is whether using today’s technology tidal arrays can be an alternative source of electrical power. In order to respond to this research question electromechanical models of tidal current devices have been developed in detail, from resource to the grid connection, using mathematical linear and non-linear programming in MATLAB/Simulink. The tidal models developed include the tidal resource, the tidal turbine with pitch control, geared induction and synchronous generators, the power electronics with the generator controller, the grid side controller, the cables for power transmission, the filters and the grid connection. All the modelling aspects of this study are presented in Chapter 3. Single tidal current devices were compared using different generator technologies, squirrel cage induction generator or permanent magnet synchronous generator, and different location of the power converters, in the nacelle near the generator or many kilometres apart from the generator. Regarding the generator technology, results showed that even though differences are minor, the permanent magnet synchronous generators are more efficient. Regarding the location of the power converters results showed that positioning the power converters in the nacelle always yields fewer electrical losses but component accessibility is minimised due to the underwater operation of the tidal current device. A key focus aspect of the study is the power transmission option with onshore converters which is presented in detail. Using this concept it is possible to generate electricity from tidal current devices but at the same time keep the highest possible system reliability despite the continuous underwater operation. This concept has been used in the first demonstration tidal current arrays developed by Andritz Hydro Hammerfest. What is more, data provided by Andritz Hydro Hammerfest were utilised in order to validate the simulation models. In this study a step forward is taken regarding the concept of keeping the converter dry and controlling the tidal current generator from afar. An algorithm is developed to design power harmonic filters for systems that use long distance controls. Power harmonic filters allow the long distance control system to operate reliably under all conditions but generate significant electrical losses. The power harmonic filter design algorithm presented in this thesis estimates the exact filter parameters so that the filter ensures maximum system reliability and generate minimum possible losses. In addition tidal array topologies using this concept are developed. The final part of this thesis compares a number of different tidal array topologies based on resource to grid efficiency and component accessibility for maintenance. Results showed that when tidal current devices are clustered per four turbines on offshore platforms it is efficient to use as many clusters as possible connected to a single cable whose both ends are connected to the grid. Locating the power converters in the nacelle yields fewer electrical losses compared to locating the power converters on the offshore platform. However, the difference is minimised because the distance between the tidal current device and the offshore platform is the least possible. Having the power converters on an offshore platform is beneficial in terms of accessibility for maintenance and operation because they are not underwater. The results and the methodology from this thesis can be extended to other offshore renewable energy systems such as the wind and wave. In addition, this study can be used as a stepping stone for decision making by tidal current developers
    corecore