302 research outputs found

    Micro-motion controller

    Get PDF
    Micro-motions in surgical applications are small motions in the range of a few millimeters and are common in ophthalmic surgery, neurosurgery, and other surgeries which require precise manipulation over short distances. Robotic surgery is replacing traditional open surgery at a rapid pace due to the obvious health benefits, however, most of the robotic surgical tools use robotic motion controllers that are designed to work over a large portion of the human body, thus involving motion of the entire human arm at shoulder joint. This requirement to move a large inertial mass results in undesirable, unwanted, and imprecise motion. This senior design project has created a 2-axis micro-motion “capable” platform, where the device studies the most common linear, 2-D surgical micro-motion of pinched human fingers in a damped and un-damped state. Through a system of printed and modeled parts in combination with motors and encoders a microsurgical controller was developed which can provide location-based output on a screen. Mechanical damping was introduced to research potential stability of micro-motion in any surgeon’s otherwise unsteady hand. The device is to also serve as a starter set for future biomedical device research projects in Santa Clara University’s bioengineering department. Further developments in the microsurgical controller such as further scaling, addition of a third axis, haptic feedback through the microcontroller, and component encasing to allow productization for use on an industrial robotic surgical device for clinical applications

    Design and realization of a master-slave system for reconstructive microsurgery

    Get PDF

    Robocatch: Design and Making of a Hand-Held Spillage-Free Specimen Retrieval Robot for Laparoscopic Surgery

    Get PDF
    Specimen retrieval is an important step in laparoscopy, a minimally invasive surgical procedure performed to diagnose and treat a myriad of medical pathologies in fields ranging from gynecology to oncology. Specimen retrieval bags (SRBs) are used to facilitate this task, while minimizing contamination of neighboring tissues and port-sites in the abdominal cavity. This manual surgical procedure requires usage of multiple ports, creating a traffic of simultaneous operations of multiple instruments in a limited shared workspace. The skill-demanding nature of this procedure makes it time-consuming, leading to surgeons’ fatigue and operational inefficiency. This thesis presents the design and making of RoboCatch, a novel hand-held robot that aids a surgeon in performing spillage-free retrieval of operative specimens in laparoscopic surgery. The proposed design significantly modifies and extends conventional instruments that are currently used by surgeons for the retrieval task: The core instrumentation of RoboCatch comprises a webbed three-fingered grasper and atraumatic forceps that are concentrically situated in a folded configuration inside a trocar. The specimen retrieval task is achieved in six stages: 1) The trocar is introduced into the surgical site through an instrument port, 2) the three webbed fingers slide out of the tube and simultaneously unfold in an umbrella like-fashion, 3) the forceps slide toward, and grasp, the excised specimen, 4) the forceps retract the grasped specimen into the center of the surrounding grasper, 5) the grasper closes to achieve a secured containment of the specimen, and 6) the grasper, along with the contained specimen, is manually removed from the abdominal cavity. The resulting reduction in the number of active ports reduces obstruction of the port-site and increases the procedure’s efficiency. The design process was initiated by acquiring crucial parameters from surgeons and creating a design table, which informed the CAD modeling of the robot structure and selection of actuation units and fabrication material. The robot prototype was first examined in CAD simulation and then fabricated using an Objet30 Prime 3D printer. Physical validation experiments were conducted to verify the functionality of different mechanisms of the robot. Further, specimen retrieval experiments were conducted with porcine meat samples to test the feasibility of the proposed design. Experimental results revealed that the robot was capable of retrieving masses of specimen ranging from 1 gram to 50 grams. The making of RoboCatch represents a significant step toward advancing the frontiers of hand-held robots for performing specimen retrieval tasks in minimally invasive surgery

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Development and preliminary results of bimanual smart micro-surgical system using a ball-lens coupled OCT distance sensor

    Get PDF
    Bimanual surgery enhances surgical effectiveness and is required to successfully accomplish complex microsurgical tasks. The essential advantage is the ability to simultaneously grasp tissue with one hand to provide counter traction or exposure, while dissecting with the other. Towards enhancing the precision and safety of bimanual microsurgery we present a bimanual SMART micro-surgical system for a preliminary ex-vivo study. To the best of our knowledge, this is the first demonstration of a handheld bimanual microsurgical system. The essential components include a ball-lens coupled common-path swept source optical coherence tomography sensor. This system effectively suppresses asynchronous hand tremor using two PZT motors in feedback control loop and efficiently assists ambidextrous tasks. It allows precise bimanual dissection of biological tissues with a reduction in operating time as compared to the same tasks performed with conventional onehanded approaches. © 2016 Optical Society of America.1

    Medical robots with potential applications in participatory and opportunistic remote sensing: A review

    Get PDF
    Among numerous applications of medical robotics, this paper concentrates on the design, optimal use and maintenance of the related technologies in the context of healthcare, rehabilitation and assistive robotics, and provides a comprehensive review of the latest advancements in the foregoing field of science and technology, while extensively dealing with the possible applications of participatory and opportunistic mobile sensing in the aforementioned domains. The main motivation for the latter choice is the variety of such applications in the settings having partial contributions to functionalities such as artery, radiosurgery, neurosurgery and vascular intervention. From a broad perspective, the aforementioned applications can be realized via various strategies and devices benefiting from detachable drives, intelligent robots, human-centric sensing and computing, miniature and micro-robots. Throughout the paper tens of subjects, including sensor-fusion, kinematic, dynamic and 3D tissue models are discussed based on the existing literature on the state-of-the-art technologies. In addition, from a managerial perspective, topics such as safety monitoring, security, privacy and evolutionary optimization of the operational efficiency are reviewed

    Force-Sensing-Based Multi-Platform Robotic Assistance for Vitreoretinal Surgery

    Get PDF
    Vitreoretinal surgery aims to treat disorders of the retina, vitreous body, and macula, such as retinal detachment, diabetic retinopathy, macular hole, epiretinal membrane and retinal vein occlusion. Challenged by several technical and human limitations, vitreoretinal practice currently ranks amongst the most demanding fields in ophthalmic surgery. Of vitreoretinal procedures, membrane peeling is the most common to be performed, over 0.5 million times annually, and among the most prone to complications. It requires an extremely delicate tissue manipulation by various micron scale maneuvers near the retina despite the physiological hand tremor of the operator. In addition, to avoid injuries, the applied forces on the retina need to be kept at a very fine level, which is often well below the tactile sensory threshold of the surgeon. Retinal vein cannulation is another demanding procedure where therapeutic agents are injected into occluded retinal veins. The feasibility of this treatment is limited due to challenges in identifying the moment of venous puncture, achieving cannulation and maintaining it throughout the drug delivery period. Recent advancements in medical robotics have significant potential to address most of the challenges in vitreoretinal practice, and therefore to prevent traumas, lessen complications, minimize intra-operative surgeon effort, maximize surgeon comfort, and promote patient safety. This dissertation presents the development of novel force-sensing tools that can easily be used on various robotic platforms, and robot control methods to produce integrated assistive surgical systems that work in partnership with surgeons against the current limitations in vitreoretinal surgery, specifically focusing on membrane peeling and vein cannulation procedures. Integrating high sensitivity force sensing into the ophthalmic instruments enables precise quantitative monitoring of applied forces. Auditory feedback based upon the measured forces can inform (and warn) the surgeon quickly during the surgery and help prevent injury due to excessive forces. Using these tools on a robotic platform can attenuate hand tremor of the surgeon, which effectively promotes tool manipulation accuracy. In addition, based upon certain force signatures, the robotic system can precisely identify critical instants, such as the venous puncture in retinal vein cannulation, and actively guide the tool towards clinical targets, compensate any involuntary motion of the surgeon, or generate additional motion that will make the surgical task easier. The experimental results using two distinct robotic platforms, the Steady-Hand Eye Robot and Micron, in combination with the force-sensing ophthalmic instruments, show significant performance improvement in artificial dry phantoms and ex vivo biological tissues

    Integrated Neuromusculoskeletal Modeling within a Finite Element Framework to Investigate Mechanisms and Treatment of Neurodegenerative Conditions

    Get PDF
    Neurodegenerative and neurodevelopmental disorders are a group of conditions that stem from irregularities in the nervous system that lead to complications in function and movement. The goal of this work is to develop computational tools that: (1) measure the accuracy of surgical interventions in neurodegenerative and neurodevelopmental conditions, and (2) integrate neural and musculoskeletal frameworks to provide a platform to better investigate neurodegenerative and neurodevelopmental disorders. Parkinson’s disease (PD) is a neurodegenerative condition projected to affect over 1.2 million people by 2030 in the US. It is caused by atypical firing patterns in the basal ganglia region of the brain that leads to primary motor symptoms of tremor, slowness of movement, and rigidity. A potential treatment for PD is deep brain stimulation (DBS). DBS involves implanting electrodes into central brain structures to regulate the pathological signaling. Electrode placement accuracy is a key metric that helps to determine patient outcomes postoperatively. An automated measurement system was developed to quantify electrode placement accuracy in robot-assisted asleep DBS procedures (Chapter 2). This measurement system allows for precise metrics without human bias in large cohorts of patients. This measurement system was later modified to measure screw placement accuracy in spinal fusion procedures for the treatment of degenerative musculoskeletal conditions (Chapter 3). DBS is an effective treatment for PD, but it is not a cure for the cause of the disease itself. To cure neurodegenerative and neurodevelopmental diseases, the underlying disease mechanisms must be better understood. A major limitation in studying neural conditions is the infeasibility of performing in vivo experiments, particularly in humans due to ethical considerations. Computational modeling, specifically fully predictive neuromusculoskeletal (NMS) models, can help to accumulate additional knowledge about neural pathways that cannot be determined experimentally. NMS models typically include complexity in either the neuromuscular or musculoskeletal system, but not both, making it difficult or infeasible to investigate the relationship between neural signaling and musculoskeletal function. To overcome this, a fully predictive NMS model was developed by integrating NEURON software within Abaqus, a finite element (FE) environment (Chapter 4). The neural model consisted of a pool of motor neurons innervating the soleus muscle in a FE human ankle model. Software integration was verified against previously published data, and the neuronal network was verified for motor unit recruitment and rate coding, which are the two principles required for in vivo muscle generation. To demonstrate the applicability of the model to study neurodegenerative and neurodevelopmental diseases, a fully predictive mouse hindlimb NMS model was developed using the integrated framework to investigate Rett syndrome (RS) (Chapter 5). RS is a neurodevelopmental disorder caused by a mutation of the Mecp2 gene with hallmark motor symptoms of a loss of purposeful hand movement, changes in muscle tone, and a loss of speech. Recent experimental analysis has found that the axon initial segment (AIS) in mice that model RS has torsional morphology compared to wildtype littermate controls. The effects these neural morphological changes have on joint motion will be studied using the mouse NMS model. This work encompasses a range of research that uses computational models to study the underlying mechanisms and design targeted treatment options for neurodegenerative and neurodevelopmental disorders. The outcomes of this work have quantified the accuracy at which surgical interventions for these conditions can be performed and have resulted in a neuromusculoskeletal model that can be applied to understand how neural morphology, and associated changes due to these disorders, affects musculoskeletal function

    Factors of Micromanipulation Accuracy and Learning

    No full text
    Micromanipulation refers to the manipulation under a microscope in order to perform delicate procedures. It is difficult for humans to manipulate objects accurately under a microscope due to tremor and imperfect perception, limiting performance. This project seeks to understand factors affecting accuracy in micromanipulation, and to propose strategies for learning improving accuracy. Psychomotor experiments were conducted using computer-controlled setups to determine how various feedback modalities and learning methods can influence micromanipulation performance. In a first experiment, static and motion accuracy of surgeons, medical students and non-medical students under different magniification levels and grip force settings were compared. A second experiment investigated whether the non-dominant hand placed close to the target can contribute to accurate pointing of the dominant hand. A third experiment tested a training strategy for micromanipulation using unstable dynamics to magnify motion error, a strategy shown to be decreasing deviation in large arm movements. Two virtual reality (VR) modules were then developed to train needle grasping and needle insertion tasks, two primitive tasks in a microsurgery suturing procedure. The modules provided the trainee with a visual display in stereoscopic view and information on their grip, tool position and angles. Using the VR module, a study examining effects of visual cues was conducted to train tool orientation. Results from these studies suggested that it is possible to learn and improve accuracy in micromanipulation using appropriate sensorimotor feedback and training

    Advances in Minimally Invasive Surgery

    Get PDF
    The minimally invasive approach in medicine is one of the most common areas of interest in surgery.Advances in Minimally Invasive Surgery describes the latest trends, indications, techniques, and approaches in minimally invasive surgery. It provides step-by-step instructions for both routine and diagnostic procedures via illustrations and video collection
    corecore