Characterization and Compensation of Hysteretic Cardiac Respiratory Motion in Myocardial Perfusion Studies Through MRI Investigations
Respiratory motion causes artifacts and blurring of cardiac structures in reconstructed images of SPECT and PET cardiac studies. Hysteresis in respiratory motion causes the organs to move in distinct paths during inspiration and expiration. Current respiratory motion correction methods use a signal generated by tracking the motion of the abdomen during respiration to bin list- mode data as a function of the magnitude of this respiratory signal. They thereby fail to account for hysteretic motion. The goal of this research was to demonstrate the effects of hysteretic respiratory motion and the importance of its correction for different medical imaging techniques particularly SPECT and PET. This study describes a novel approach for detecting and correcting hysteresis in clinical SPECT and PET studies. From the combined use of MRI and a synchronized Visual Tracking System (VTS) in volunteers we developed hysteretic modeling using the Bouc-Wen model with inputs from measurements of both chest and abdomen respiratory motion. With the MRI determined heart motion as the truth in the volunteer studies we determined the Bouc Wen model could match the behavior over a range of hysteretic cycles. The proposed approach was validated through phantom simulations and applied to clinical SPECT studies
4D flow MRI in abdominal vessels: prospective comparison of k-t accelerated free breathing acquisition to standard respiratory navigator gated acquisition
Volumetric phase-contrast magnetic resonance imaging with three-dimensional velocity encoding (4D flow MRI) has shown utility as a non-invasive tool to examine altered blood flow in chronic liver disease. Novel 4D flow MRI pulse sequences with spatio-temporal acceleration can mitigate the long acquisition times of standard 4D flow MRI, which are an impediment to clinical adoption. The purpose of our study was to demonstrate feasibility of a free-breathing, spatio-temporal (k-t) accelerated 4D flow MRI acquisition for flow quantification in abdominal vessels and to compare its image quality, flow quantification and inter-observer reproducibility with a standard respiratory navigator-gated 4D flow MRI acquisition. Ten prospectively enrolled patients (M/F: 7/3, mean age = 58y) with suspected portal hypertension underwent both 4D flow MRI acquisitions. The k-t accelerated acquisition was approximately three times faster (3:11 min ± 0:12 min/9:17 min ± 1:41 min, p < 0.001) than the standard respiratory-triggered acquisition. Vessel identification agreement was substantial between acquisitions and observers. Average flow had substantial inter-sequence agreement in the portal vein and aorta (CV < 15%) and poorer agreement in hepatic and splenic arteries (CV = 11-38%). The k-t accelerated acquisition recorded reduced velocities in small arteries and reduced splenic vein flow. Respiratory gating combined with increased acceleration and spatial resolution are needed to improve flow measurements in these vessels
Two-Minute k-Space and Time–accelerated Aortic Four-dimensional Flow MRI: Dual-Center Study of Feasibility and Impact on Velocity and Wall Shear Stress Quantification
PURPOSE: To investigate the two-center feasibility of highly k-space and time (k-t)–accelerated 2-minute aortic four-dimensional (4D) flow MRI and to evaluate its performance for the quantification of velocities and wall shear stress (WSS).
MATERIALS AND METHODS: This cross-sectional study prospectively included 68 participants (center 1, 11 healthy volunteers [mean age ± standard deviation, 61 years ± 15] and 16 patients with aortic disease [mean age, 60 years ± 10]; center 2, 14 healthy volunteers [mean age, 38 years ± 13] and 27 patients with aortic or cardiac disease [mean age, 78 years ± 18]). Each participant underwent highly accelerated 4D flow MRI (k-t acceleration, acceleration factor of 5) of the thoracic aorta. For comparison, conventional 4D flow MRI (acceleration factor of 2) was acquired in the participants at center 1 (n = 27). Regional aortic peak systolic velocities and three-dimensional WSS were quantified.
RESULTS: k-t–accelerated scan times (center 1, 2:03 minutes ± 0:29; center 2, 2:06 minutes ± 0:20) were significantly reduced compared with conventional 4D flow MRI (center 1, 12:38 minutes ± 2:25; P < .0001). Overall good agreement was found between the two techniques (absolute differences ≤15%), but proximal aortic WSS was significantly underestimated in patients by using k-t–accelerated 4D flow when compared with conventional 4D flow (P ≤ .03). k-t–accelerated 4D flow MRI was reproducible (intra- and interobserver intraclass correlation coefficient ≥0.98) and identified significantly increased peak velocities and WSS in patients with stenotic (P ≤ .003) or bicuspid (P ≤ .04) aortic valves compared with healthy volunteers. In addition, k-t–accelerated 4D flow MRI–derived velocities and WSS were inversely related to age (r ≥−0.53; P ≤ .03) over all healthy volunteers.
CONCLUSION: k-t–accelerated aortic 4D flow MRI providing 2-minute scan times was feasible and reproducible at two centers. Although consistent healthy aging- and disease-related changes in aortic hemodynamics were observed, care should be taken when considering WSS, which can be underestimated in patients
Recommended from our members
Advanced H-1 Lung Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is one of the widely used medical imaging modality, since it can provide both structural and functional assessment in a single imaging session. However, two major challenges should be considered by using MRI for lung imaging. The first challenge is the intrinsic low SNR of H-1 lung MRI due to the low proton density as well as the fast decay of the lung parenchyma signal. And the second challenge is subject motion. To achieve high resolution structural image, MRI requires a long scan time, usually a few minutes or even longer, which make MRI sensitive to subject motion. To address the first challenge, ultra-short echo time (UTE) MRI sequence is used to capture the lung parenchyma signal before decay. As for subject motion, two major strategies are widely used. One strategy is fast breath-holding scan, the subjects are asked to hold their breaths for a short duration, and the fast 3D MR sequence would be used to acquire data within that duration. This dissertation proposes a new acquisition scheme based on the standard UTE sequence, which largely increases the encoding efficiency and improves the breath-holding scan images. The other is free breathing scan with motion correction. The subjects are allowed to breathe during the MR acquisition. After the acquisition, the motion corrupted data would go through the motion correction step to reconstruct the motion free images. In this dissertation, two novel motion corrected reconstruction strategies are proposed to incorporate the motion modeling and compensation into the reconstruction to get high SNR motion corrected 3D and 4D images. When translating the developed techniques to the clinical studies, specifically for pediatric and neonatal studies, more practical problems need to be considered, such as smaller but finer anatomy to image, the different respiratory patterns of the young subjects etc. This dissertation proposes a 5-minute free breathing UTE MRI strategy to achieve a 3D high resolution motion free lung image for pediatric and neonatal studies
Synthesis of Realistic Simultaneous Positron Emission Tomography and Magnetic Resonance Imaging Data
The investigation of the performance of different positron emission tomography (PET) reconstruction and motion compensation methods requires accurate and realistic representation of the anatomy and motion trajectories as observed in real subjects during acquisitions. The generation of well-controlled clinical datasets is difficult due to the many different clinical protocols, scanner specifications, patient sizes, and physiological variations. Alternatively, computational phantoms can be used to generate large data sets for different disease states, providing a ground truth. Several studies use registration of dynamic images to derive voxel deformations to create moving computational phantoms. These phantoms together with simulation software generate raw data. This paper proposes a method for the synthesis of dynamic PET data using a fast analytic method. This is achieved by incorporating realistic models of respiratory motion into a numerical phantom to generate datasets with continuous and variable motion with magnetic resonance imaging (MRI)-derived motion modeling and high resolution MRI images. In this paper, data sets for two different clinical traces are presented, ¹⁸F-FDG and ⁶⁸Ga-PSMA. This approach incorporates realistic models of respiratory motion to generate temporally and spatially correlated MRI and PET data sets, as those expected to be obtained from simultaneous PET-MRI acquisitions
4D MRI: Robust sorting of free breathing MRI slices for use in interventional settings
Purpose: We aim to develop a robust 4D MRI method for large FOVs enabling the
extraction of irregular respiratory motion that is readily usable with all MRI
machines and thus applicable to support a wide range of interventional
settings.
Method: We propose a 4D MRI reconstruction method to capture an arbitrary
number of breathing states. It uses template updates in navigator slices and
search regions for fast and robust vessel cross-section tracking. It captures
FOVs of 255 mm x 320 mm x 228 mm at a spatial resolution of 1.82 mm x 1.82 mm x
4mm and temporal resolution of 200ms. A total of 37 4D MRIs of 13 healthy
subjects were reconstructed to validate the method. A quantitative evaluation
of the reconstruction rate and speed of both the new and baseline method was
performed. Additionally, a study with ten radiologists was conducted to assess
the subjective reconstruction quality of both methods.
Results: Our results indicate improved mean reconstruction rates compared to
the baseline method (79.4\% vs. 45.5\%) and improved mean reconstruction times
(24s vs. 73s) per subject. Interventional radiologists perceive the
reconstruction quality of our method as higher compared to the baseline (262.5
points vs. 217.5 points, p=0.02).
Conclusions: Template updates are an effective and efficient way to increase
4D MRI reconstruction rates and to achieve better reconstruction quality.
Search regions reduce reconstruction time. These improvements increase the
applicability of 4D MRI as a base for seamless support of interventional image
guidance in percutaneous interventions.Comment: 16 pages, 11 figure
- …