457 research outputs found

    The Development of a Capacitance-Based Biotelemetry System for Implantable Applications

    Get PDF
    Most modern biomedical implants implement some form of communications link between the implant and the outside world. This biotelemetry link has many requirements such as data bandwidth and power consumption. Designing an appropriate link that meets these requirements is one of the most significant engineering challenges associated with these implants. Communications methods that are currently used for this link include standard Radio Frequency (RF) approaches, inductively coupled approaches, and load modulation approaches. This thesis describes the development of a unique capacitance-based biotelemetry system for implantable applications. This system consists of two distinct parts: the implanted transmitter and the external body-mounted receiver. The prototype transmitter is based on a custom Application Specific Integrated Circuit (ASIC) fabricated using the AMI 1.5µ process. This ASIC encodes and transmits predetermined data packets by driving two electrodes in a slew-controlled manner, all contained within a biocompatible material. The receiver consists of charge-sensitive amplifier front end using a discriminator to distinguish individual bits. A Field Programmable Gate Array (FPGA) decodes the transmitted data and relays it to a PC- based LabVIEW interface. Test results using a saline-based human tissue model are presented

    Advanced sensors technology survey

    Get PDF
    This project assesses the state-of-the-art in advanced or 'smart' sensors technology for NASA Life Sciences research applications with an emphasis on those sensors with potential applications on the space station freedom (SSF). The objectives are: (1) to conduct literature reviews on relevant advanced sensor technology; (2) to interview various scientists and engineers in industry, academia, and government who are knowledgeable on this topic; (3) to provide viewpoints and opinions regarding the potential applications of this technology on the SSF; and (4) to provide summary charts of relevant technologies and centers where these technologies are being developed

    Nano-Watt Modular Integrated Circuits for Wireless Neural Interface.

    Full text link
    In this work, a nano-watt modular neural interface circuit is proposed for ECoG neuroprosthetics. The main purposes of this work are threefold: (1) optimizing the power-performance of the neural interface circuits based on ECoG signal characteristics, (2) equipping a stimulation capability, and (3) providing a modular system solution to expand functionality. To achieve these aims, the proposed system introduces the following contributions/innovations: (1) power-noise optimization based on the ECoG signal driven analysis, (2) extreme low-power analog front-ends, (3) Manchester clock-edge modulation clock data recovery, (4) power-efficient data compression, (5) integrated stimulator with fully programmable waveform, (6) wireless signal transmission through skin, and (7) modular expandable design. Towards these challenges and contributions, three different ECoG neural interface systems, ENI-1, ENI-16, and ENI-32, have been designed, fabricated, and tested. The first ENI system(ENI-1) is a one-channel analog front-end and fabricated in a 0.25µm CMOS process with chopper stabilized pseudo open-loop preamplifier and area-efficient SAR ADC. The measured channel power, noise and area are 1.68µW at 2.5V power-supply, 1.69µVrms (NEF=2.43), and 0.0694mm^2, respectively. The fabricated IC is packaged with customized miniaturized package. In-vivo human EEG is successfully measured with the fabricated ENI-1-IC. To demonstrate a system expandability and wireless link, ENI-16 IC is fabricated in 0.25µm CMOS process and has sixteen channels with a push-pull preamplifier, asynchronous SAR ADC, and intra-skin communication(ISCOM) which is a new way of transmitting the signal through skin. The measured channel power, noise and area are 780nW, 4.26µVrms (NEF=5.2), and 2.88mm^2, respectively. With the fabricated ENI-16-IC, in-vivo epidural ECoG from monkey is successfully measured. As a closed-loop system, ENI-32 focuses on optimizing the power performance based on a bio-signal property and integrating stimulator. ENI-32 is fabricated in 0.18µm CMOS process and has thirty-two recording channels and four stimulation channels with a cyclic preamplifier, data compression, asymmetric wireless transceiver (Tx/Rx). The measured channel power, noise and area are 140nW (680nW including ISCOM), 3.26µVrms (NEF=1.6), and 5.76mm^2, respectively. The ENI-32 achieves an order of magnitude power reduction while maintaining the system performance. The proposed nano-watt ENI-32 can be the first practical wireless closed-loop solution with a practically miniaturized implantable device.PhDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/98064/1/schang_1.pd

    Soft, curved electrode systems capable of integration on the auricle as a persistent brain–computer interface

    Get PDF
    Recent advances in electrodes for noninvasive recording of electroencephalograms expand opportunities collecting such data for diagnosis of neurological disorders and brain–computer interfaces. Existing technologies, however, cannot be used effectively in continuous, uninterrupted modes for more than a few days due to irritation and irreversible degradation in the electrical and mechanical properties of the skin interface. Here we introduce a soft, foldable collection of electrodes in open, fractal mesh geometries that can mount directly and chronically on the complex surface topology of the auricle and the mastoid, to provide high-fidelity and long-term capture of electroencephalograms in ways that avoid any significant thermal, electrical, or mechanical loading of the skin. Experimental and computational studies establish the fundamental aspects of the bending and stretching mechanics that enable this type of intimate integration on the highly irregular and textured surfaces of the auricle. Cell level tests and thermal imaging studies establish the biocompatibility and wearability of such systems, with examples of high-quality measurements over periods of 2 wk with devices that remain mounted throughout daily activities including vigorous exercise, swimming, sleeping, and bathing. Demonstrations include a text speller with a steady-state visually evoked potential-based brain–computer interface and elicitation of an event-related potential (P300 wave)

    Wireless system for the measurement of bioelectric signals using capacitive electrodes

    Get PDF
    Català: Aquest projecte mostra el disseny i la implementació d'un sistema d'adquisició de senyals bioelèctriques mitjançant elèctrodes capacitius. El sistema, inalàmbric i a bateria, envia les dades a un ordinador per a la seva visualització o processament.Castellano: Este proyecto muestra el diseño y la implementación de un sistema de adquisición de señales bioeléctricas mediante electrodos capacitivos. El sistema, inalámbrico y a batería, envía los datos a un ordenador para su visualización o procesamiento.English: This project shows the design and implementation of an acquisition system for the measurement of bioelectric signals by means of capacitive electrodes. The system, which is wireless and battery powered, sends the data to a computer for its visualizations or processing

    Wearable impedance plethysmography and electrocardiography sensor

    Get PDF
    Wearable technology has become increasingly popular in the last few years. This project describes the design and implementation of a wearable impedance plethysmography and electrocardiography sensor. This sensor is developed to be compact and lightweight while having a very extended battery life. This way, it can be easily integrated into other wearable devices or into clothing or shoes. The acquired IPG and ECG data will be transmitted in real-time to a receiving host for further storage and processing by using the Bluetooth Low Energy protocol. By using a so widespread low energy wireless protocol, the data can be received into any compatible device, such as smartphones, laptops or even specialized systems. An android application showing a real-time graphic of the measured signals is also developed for demonstration purposes. To meet the low power consumption requirements of the analog front-end circuitry, multiple techniques were used, such as using low power versions of components such as operational amplifiers and even taking advantage of their limitations to improve circuit performance characteristics. Other techniques such as sensing the correct placement of electrodes or disabling parts of the circuitry when not needed or the signal is not available were also used. A current consumption for the analog frontend in the order of only 100 µA to 200 µA at 3V was achieved while continuously providing both IPG and ECG data. For the digital circuitry, consisting mainly of the nRF51822 System on Chip from Nordic Semiconductor and some peripherals, multiple techniques of power consumption minimization were also used. A current consumption of around 200 µA to 300 µA was achieved, again at 3V, during continuous data processing and transmission. A prototype was implemented on a PCB. Unfortunately, full functionality was not achieved mainly due to some hardware failures and time constraints, however, as multiple innovative solutions were implemented, this work will provide useful information to improve other research projects in this area.Objectius de Desenvolupament Sostenible::3 - Salut i Benesta

    A Low-Power Wireless Multichannel Microsystem for Reliable Neural Recording.

    Full text link
    This thesis reports on the development of a reliable, single-chip, multichannel wireless biotelemetry microsystem intended for extracellular neural recording from awake, mobile, and small animal models. The inherently conflicting requirements of low power and reliability are addressed in the proposed microsystem at architectural and circuit levels. Through employing the preliminary microsystems in various in-vivo experiments, the system requirements for reliable neural recording are identified and addressed at architectural level through the analytical tool: signal path co-optimization. The 2.85mm×3.84mm, mixed-signal ASIC integrates a low-noise front-end, programmable digital controller, an RF modulator, and an RF power amplifier (PA) at the ISM band of 433MHz on a single-chip; and is fabricated using a 0.5µm double-poly triple-metal n-well standard CMOS process. The proposed microsystem, incorporating the ASIC, is a 9-channel (8-neural, 1-audio) user programmable reliable wireless neural telemetry microsystem with a weight of 2.2g (including two 1.5V batteries) and size of 2.2×1.1×0.5cm3. The electrical characteristics of this microsystem are extensively characterized via benchtop tests. The transmitter consumes 5mW and has a measured total input referred voltage noise of 4.74µVrms, 6.47µVrms, and 8.27µVrms at transmission distances of 3m, 10m, and 20m, respectively. The measured inter-channel crosstalk is less than 3.5% and battery life is about an hour. To compare the wireless neural telemetry systems, a figure of merit (FoM) is defined as the reciprocal of the power spent on broadcasting one channel over one meter distance. The proposed microsystem’s FoM is an order of magnitude larger compared to all other research and commercial systems. The proposed biotelemetry system has been successfully used in two in-vivo neural recording experiments: i) from a freely roaming South-American cockroach, and ii) from an awake and mobile rat.Ph.D.Electrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/91542/1/aborna_1.pd

    Evaluation of Propagation Characteristics Using the Human Body as an Antenna

    Get PDF
    In this paper, an inhomogeneous human body model was presented to investigate the propagation characteristics when the human body was used as an antenna to achieve signal transmission. Specifically, the channel gain of four scenarios, namely, (1) both TX electrode and RX electrode were placed in the air, (2) TX electrode was attached on the human body, and RX electrode was placed in the air, (3) TX electrode was placed in the air, and RX electrode was attached on the human body, (4) both the TX electrode and RX electrode were attached on the human body, were studied through numerical simulation in the frequency range 1 MHz to 90 MHz. Furthermore, the comparisons of input efficiency, accepted efficiency, total efficiency, absorption power of human body, and electric field distribution of different distances of four aforementioned scenarios were explored when the frequency was at 44 MHz. In addition, the influences of different human tissues, electrode position, and the distance between electrode and human body on the propagation characteristics were investigated respectively at 44 MHz. The results showed that the channel gain of Scenario 4 was the maximum when the frequency was from 1 MHz to 90 MHz. The propagation characteristics were almost independent of electrode position when the human body was using as an antenna. However, as the distance between TX electrode and human body increased, the channel gain decreased rapidly. The simulations were verified by experimental measurements. The results showed that the simulations were in agreement with the measurements

    Development and modelling of a versatile active micro-electrode array for high density in-vivo and in-vitro neural signal investigation

    Get PDF
    The electrophysiological observation of neurological cells has allowed much knowledge to be gathered regarding how living organisms are believed to acquire and process sensation. Although much has been learned about neurons in isolation, there is much more to be discovered in how these neurons communicate within large networks. The challenges of measuring neurological networks at the scale, density and chronic level of non invasiveness required to observe neurological processing and decision making are manifold, however methods have been suggested that have allowed small scale networks to be observed using arrays of micro-fabricated electrodes. These arrays transduce ionic perturbations local to the cell membrane in the extracellular fluid into small electrical signals within the metal that may be measured. A device was designed for optimal electrical matching to the electrode interface and maximal signal preservation of the received extracellular neural signals. Design parameters were developed from electrophysiological computer simulations and experimentally obtained empirical models of the electrode-electrolyte interface. From this information, a novel interface based signal filtering method was developed that enabled high density amplifier interface circuitry to be realised. A novel prototype monolithic active electrode was developed using CMOS microfabrication technology. The device uses the top metallization of a selected process to form the electrode substrate and compact amplification circuitry fabricated directly beneath the electrode to amplify and separate the neural signal from the baseline offsets and noise of the electrode interface. The signal is then buffered for high speed sampling and switched signal routing. Prototype 16 and 256 active electrode array with custom support circuitry is presented at the layout stage for a 20 ÎĽm diameter 100 ÎĽm pitch electrode array. Each device consumes 26.4 ÎĽW of power and contributes 4.509 ÎĽV (rms) of noise to the received signal over a controlled bandwidth of 10 Hz - 5 kHz. The research has provided a fundamental insight into the challenges of high density neural network observation, both in the passive and the active manner. The thesis concludes that power consumption is the fundamental limiting factor of high density integrated MEA circuitry; low power dissipation being crucial for the existence of the surface adhered cells under measurement. With transistor sizing, noise and signal slewing each being inversely proportional to the dc supply current and the large power requirements of desirable ancillary circuitry such as analogue-to-digital converters, a situation of compromise is approached that must be carefully considered for specific application design
    • …
    corecore