5,489 research outputs found

    Design and numerical simulation of the real-time particle charge and size analyser

    Get PDF
    The electrostatic charge and size distribution of aerosol particles play a very important role in many industrial applications. Due to the complexity and the probabilistic nature of the different charging mechanisms often acting simultaneously, it is difficult to theoretically predict the charge distribution of aerosol particles or even estimate the relative effect of the different mechanisms. Therefore, it is necessary to measure the size and also the bipolar charge distribution on aerosol particles. The main aim of this research project was to design, implement and simulate a signal processing system for novel, fully functional measurement instrument capable of simultaneously measuring in real time the bipolar charge and size distribution of medical aerosols. The Particle Size and Charge Analyser (PSCA), investigated in this thesis, uses Phase Doppler Anemometry (PDA) technique. The PDA system was used to track the motion of charged particles in the presence of an electric field. By solving the equation of particle motion in a viscous medium combined with the simultaneous measurement of its size and velocity, the magnitude as well as the polarity of the particle charge can be obtained. Different signal processing systems in different excitation fields have been designed and implemented. These systems include: velocity estimation system using spectral analysis in DC excitation field, velocity estimation system based on Phase Locked Loop (PLL) technique working in DC as well as sine-wave excitation fields, velocity estimation system based on Quadrature Demodulation (QD) technique under sine-wave excitation method, velocity estimation system using spectral analysis in square-wave excitation field and phase shift estimation based on Hilbert transformation and correlation technique in both sine-wave and square-wave excitation fields. The performances of these systems were evaluated using Monte Carlo (MC) simulations obtained from the synthesized Doppler burst signals generated from the mathematical models implemented in MATLAB. The synthesized Doppler Burst Signal (DBS) was subsequently corrupted with the added Gaussian noise. Cross validation of the results was performed using hardware signal processing system employing Arbitrary Waveform Generator and also NASA simulator to further confirm the validity of the estimation

    An accuracy assessment of Magellan Very Long Baseline Interferometry (VLBI)

    Get PDF
    Very Long Baseline Interferometry (VLBI) measurements of the Magellan spacecraft's angular position and velocity were made during July through September, 1989, during the spacecraft's heliocentric flight to Venus. The purpose of this data acquisition and reduction was to verify this data type for operational use before Magellan is inserted into Venus orbit, in August, 1990. The accuracy of these measurements are shown to be within 20 nanoradians in angular position, and within 5 picoradians/sec in angular velocity. The media effects and their calibrations are quantified; the wet fluctuating troposphere is the dominant source of measurement error for angular velocity. The charged particle effect is completely calibrated with S- and X-Band dual-frequency calibrations. Increasing the accuracy of the Earth platform model parameters, by using VLBI-derived tracking station locations consistent with the planetary ephemeris frame, and by including high frequency Earth tidal terms in the Earth rotation model, add a few nanoradians improvement to the angular position measurements. Angular velocity measurements were insensitive to these Earth platform modelling improvements

    Theory of CW lidar aerosol backscatter measurements and development of a 2.1 microns solid-state pulsed laser radar for aerosol backscatter profiling

    Get PDF
    The performance and calibration of a focused, continuous wave, coherent detection CO2 lidar operated for the measurement of atmospheric backscatter coefficient, B(m), was examined. This instrument functions by transmitting infrared (10 micron) light into the atmosphere and collecting the light which is scattered in the rearward direction. Two distinct modes of operation were considered. In volume mode, the scattered light energy from many aerosols is detected simultaneously, whereas in the single particle mode (SPM), the scattered light energy from a single aerosol is detected. The analysis considered possible sources of error for each of these two cases, and also considered the conditions where each technique would have superior performance. The analysis showed that, within reasonable assumptions, the value of B(m) could be accurately measured by either the VM or the SPM method. The understanding of the theory developed during the analysis was also applied to a pulsed CO2 lidar. Preliminary results of field testing of a solid state 2 micron lidar using a CW oscillator is included

    Optimization of fringe-type laser anemometers for turbine engine component testing

    Get PDF
    The fringe type laser anemometer is analyzed using the Cramer-Rao bound for the variance of the estimate of the Doppler frequency as a figure of merit. Mie scattering theory is used to calculate the Doppler signal wherein both the amplitude and phase of the scattered light are taken into account. The noise from wall scatter is calculated using the wall bidirectional reflectivity and the irradiance of the incident beams. A procedure is described to determine the optimum aperture mask for the probe volume located a given distance from a wall. The expected performance of counter type processors is also discussed in relation to the Cramer-Rao bound. Numerical examples are presented for a coaxial backscatter anemometer

    Three-component laser anemometer measurement systems

    Get PDF
    A brief overview of the different laser anemometer (LA) optical designs available is presented. Then, the LA techniques that can be used to design a three-component measurement system for annular geometries are described. Some of the facility design considerations unique to these LA systems are also addressed. Following this, the facilities and the LA systems that were used to successfully measure the three components of velocity in the blading of annular-flow machines are reviewed. Finally, possible LA system enhancements and future research directions are presented

    Generation of a monodispersed aerosol

    Get PDF
    The identity and laboratory test methods for the generation of a monodispersed aerosol are reported on, and are subjected to the following constraints and parameters; (1) size distribution; (2) specific gravity; (3) scattering properties; (4) costs; (5) production. The procedure called for the collection of information from the literature, commercial available products, and experts working in the field. The following topics were investigated: (1) aerosols; (2) air pollution -- analysis; (3) atomizers; (4) dispersion; (5) particles -- optics, size analysis; (6) smoke -- generators, density measurements; (7) sprays; (8) wind tunnels -- visualization

    Structure and entrainment in the plane of symmetry of a turbulent spot

    Get PDF
    Laser-Doppler velocity measurements in water are reported for the flow in the plane of symmetry of a turbulent spot. The unsteady mean flow, defined as an ensemble average, is fitted to a conical growth law by using data at three streamwise stations to determine the virtual origin in x and t. The two-dimensional unsteady stream function is expressed as ψ=U^2_∞tg(ξ,η) in conical similarity co-ordinates ζ = x/U_∞t and η = y/U_∞t. In these co-ordinates, the equations for the unsteady particle displacements reduce to an autonomous system. This system is integrated graphically to obtain particle trajectories in invariant form. Strong entrainment is found to occur along the outer part of the rear interface and also in front of the spot near the wall. The outer part of the forward interface is passive. In terms of particle trajectories in conical co-ordinates, the main vortex in the spot appears as a stable focus with celerity 0·77U_∞. A second stable focus with celerity 0·64U_∞ also appears near the wall at the rear of the spot. Some results obtained by flow visualization with a dense, nearly opaque suspension of aluminium flakes are also reported. Photographs of the sublayer flow viewed through a glass wall show the expected longitudinal streaks. These are tentatively interpreted as longitudinal vortices caused by an instability of Taylor-Görtler type in the sublayer

    A Cavitation Susceptability Meter with Optical Cavitation Monitoring-Part One: Design Concepts

    Get PDF
    This work is concerned with the design of a Cavitation Susceptibility Meter based on the use of a venturi tube for the measurement of the active cavitation nuclei concentration in water samples as a function of the applied tension. The operation of the Cavitation Susceptibility Meter is analyzed and the main considerations leading to the proposed design are illustrated and critically discussed. The results of this analysis indicate that the operational range is mainly limited by nuclei interference, flow separation and saturation (choking), and suggest to develop a Cavitation Susceptibility Meter where; (1) the flow possesses a laminar potential core throughout the venturi throat section in all operational conditions; (b) the pressure at the venturi throat is determined from the upstream pressure and the local flow velocity; (c) the detection of cavitation and the measurement of the flow velocity are carried out optically by means of a Laser Doppler Velocimeter; (d) a custom-made electronic Signal Processor incorporating a frequency counter is used for real time data generation and temporary storage; (e) a computerized system performs the final acquisition and reduction of the data
    corecore