1,471 research outputs found

    SIMULATION AND MITIGATION OF POWER QUALITY DISTURBANCES ON A DISTRIBUTION SYSTEM USING DVR

    Get PDF
    Voltage sag is the most important power quality problem faced by many industrial customers. Equipment such as process controllers, programmable logic controllers, adjustable speed drives, robotics, etc used in modern industrial plants are actually becoming more sensitive to voltage sags. Voltage sags are normally described by the magnitude variation and duration, and also characterized by unbalance, non-sinusoidal wave shape and phase angle shift. One of the most common mitigation solution is installing uninterrupted power supply (UPS). To meet the demand for more efficient mitigation solution, the Dynamic Voltage Restorer (DVR) will be deployed. When a fault occurs, either at the high voltage source end or at the consumer end, the DVR injects active and reactive power for the restoration of the voltage sags in the network. This thesis presents the power quality problems faced by the power distribution systems in general and then concentrates on analyzing an important and specific distribution system in particular. A dynamic voltage restorer (DVR) is connected on the 11KV of an utility feeder to Ipoh hospital, in reducing the voltage sags, that affect the operation of sensitive loads to the hospital. Case studies were conducted at four industrial sites (Hitachi plant and Nihoncanpack at Bemban, Filrex at Bercham and Ipoh Hospital) by monitoring and taking physical sag measurements for a period of one month. The real time measurements were carried out to identify the types power quality disturbances that exits in the various plants before providing the custom power device as a mitigation tool. The Ipoh Hospital is taken for a special case study since the hospital has to maintain high quality power supply to the medical equipments such as CT Scan, Magnetic Resonance Imaging (MRI), Magnetic Scanner, X-ray unit, and other life savingequipment. For simulation study, PSS/ADEPT and PSCAD/EMTDC software packages were used in modeling of the power distribution system. With the PSS/ADEPT simulation tool, the voltage severity is studied by introducing different types of faults. The PSCAD/EMTDC is a graphical user interface simulation tool to simulate sag waveforms for various types of faults. A DVR was modeled using the PSCAD/EMTDC software and simulated for voltage sag mitigation. The recorded waveform shows the DVR as a potential custom power solution provider. The DVR can improve the overall voltage regulation. The results obtained from the DVR show that the voltage sags are reduced by bringing the supply voltage level to 100%. The simulated results were verified for selected faults theoretically. v

    Fault detection in a three-phase inverter fed circuit: Enhancing the Tripping capability of a UPS circuit breaker using wave shape recognition algorithm

    Get PDF
    Uninterruptible power supplies (UPS) are electrical devices that protect sensitive loads from power line disturbances such as source side overcurrents caused by overvoltage and power surges. The critical load in a double conversion UPS system is supplied from an invert-er. When overcurrents occur on the load side of double conversion UPS systems, both the UPS system’s inverter and the critical load connected to it stand a high risk of damage. Load side overcurrents due to short circuits, ground faults and motor/transformer start-up are very damaging to power electronic components, electrical equipment and cable connections. There exists circuit breakers on the load side designed to trip when a huge overcurrent occurs, thereby clearing the fault. A circuit breaker is normally sized and installed based on the maxi-mum capacity of the host system and trips when a predetermined overcurrent is recorded within a specific period of time. The UPS system’s inverter has a pre-set current limit value to protect insulated-gate bipolar transistors (IGBTs) from damage. During an overcurrent, invert-ers can supply a fault current whose peak value is limited to the IGBT current limit value. This inverter supplied fault current is not high enough to trip the circuit breaker. After an extended period of overcurrent, UPS internal tripping will be activated and all loads lose power. Opera-tion of the UPS in bypass mode supplies the required fault current but exposes the sensitive load to power line distortions. Therefore, it is desired to always supply the critical load via the inverter. This study targets to design a detection algorithm for short circuits and ground faults with a detection time faster than the UPS system’s internal tripping in order to isolate the faulted ar-ea, when the inverter is supplying the critical load. To achieve this, first, a MATLAB model was designed to aid in preliminary studies of fault detection through analysing the system behaviour. Secondly, literature review was conducted and a fault detection method selected with the help of the MATLAB model. Next, laboratory tests on a real UPS system were carried out and compared to the MATLAB results. Lastly, the detection algorithm was designed, im-plemented and tested on a real double conversion UPS system. The test results indicate that the implemented detection algorithm successfully detects short circuits and ground faults well within the desired time. It also successfully distinguishes short circuits and ground faults from other sources of overcurrents such as overloading and transformer inrush current. Future development of this study includes additional features such as a fault classification method proposed for implementation to improve the UPS debugging process during maintenance. Moreover, the detection algorithm will also be refined and devel-oped further to activate a circuit that discharges a current pulse to increase the fault current fed to the circuit breaker

    Multilevel Converters: An Enabling Technology for High-Power Applications

    Get PDF
    | Multilevel converters are considered today as the state-of-the-art power-conversion systems for high-power and power-quality demanding applications. This paper presents a tutorial on this technology, covering the operating principle and the different power circuit topologies, modulation methods, technical issues and industry applications. Special attention is given to established technology already found in industry with more in-depth and self-contained information, while recent advances and state-of-the-art contributions are addressed with useful references. This paper serves as an introduction to the subject for the not-familiarized reader, as well as an update or reference for academics and practicing engineers working in the field of industrial and power electronics.Ministerio de Ciencia y Tecnología DPI2001-3089Ministerio de Eduación y Ciencia d TEC2006-0386

    European White Book on Real-Time Power Hardware in the Loop Testing : DERlab Report No. R- 005.0

    Get PDF
    The European White Book on Real-Time-Powerhardware-in-the-Loop testing is intended to serve as a reference document on the future of testing of electrical power equipment, with specifi c focus on the emerging hardware-in-the-loop activities and application thereof within testing facilities and procedures. It will provide an outlook of how this powerful tool can be utilised to support the development, testing and validation of specifi cally DER equipment. It aims to report on international experience gained thus far and provides case studies on developments and specifi c technical issues, such as the hardware/software interface. This white book compliments the already existing series of DERlab European white books, covering topics such as grid-inverters and grid-connected storag

    Dynamic Stiffness Based Control for a MicroGrid Microsource Interface

    Get PDF

    Improving skills in rounding off the whole number

    Get PDF
    This study was conducted to address teaching and learning skills in rounding off a whole number. This study consisted of 15 years 4 students from the Kong Nan Chinese Primary School, Parit Raja, Johor, Malaysia. Initial survey to identify this problem was carried out by analyzing the exercise books and exercises in pre-test. Based on these analyses, a large number of students were not proficient in relevant skills. A ‘q’ technique was introduced as an approach in teaching and learning to help students master the skills of rounding whole numbers. In summary, this technique helps students to remember the sequence of processes and process in rounding numbers. A total of four sessions of teaching and learning activities that take less than an hour have been implemented specifically to help students to master this technique. Results of the implementation of these activities have shown very positive results among the students. Two post tests were carried out to see the effectiveness of techniques and the results shows that 100% of students were able to answer correctly at least three questions correctly. The t-test analysis was clearly showed the effectiveness of ‘q’ technique. This technique also indirectly helps to maintain and increase student interest in learning Mathematics. This is shown with the active involvement of students in answering questions given by the teacher

    Robust Control of Wide Bandgap Power Electronics Device Enabled Smart Grid

    Get PDF
    abstract: In recent years, wide bandgap (WBG) devices enable power converters with higher power density and higher efficiency. On the other hand, smart grid technologies are getting mature due to new battery technology and computer technology. In the near future, the two technologies will form the next generation of smart grid enabled by WBG devices. This dissertation deals with two applications: silicon carbide (SiC) device used for medium voltage level interface (7.2 kV to 240 V) and gallium nitride (GaN) device used for low voltage level interface (240 V/120 V). A 20 kW solid state transformer (SST) is designed with 6 kHz switching frequency SiC rectifier. Then three robust control design methods are proposed for each of its smart grid operation modes. In grid connected mode, a new LCL filter design method is proposed considering grid voltage THD, grid current THD and current regulation loop robust stability with respect to the grid impedance change. In grid islanded mode, µ synthesis method combined with variable structure control is used to design a robust controller for grid voltage regulation. For grid emergency mode, multivariable controller designed using H infinity synthesis method is proposed for accurate power sharing. Controller-hardware-in-the-loop (CHIL) testbed considering 7-SST system is setup with Real Time Digital Simulator (RTDS). The real TMS320F28335 DSP and Spartan 6 FPGA control board is used to interface a switching model SST in RTDS. And the proposed control methods are tested. For low voltage level application, a 3.3 kW smart grid hardware is built with 3 GaN inverters. The inverters are designed with the GaN device characterized using the proposed multi-function double pulse tester. The inverter is controlled by onboard TMS320F28379D dual core DSP with 200 kHz sampling frequency. Each inverter is tested to process 2.2 kW power with overall efficiency of 96.5 % at room temperature. The smart grid monitor system and fault interrupt devices (FID) based on Arduino Mega2560 are built and tested. The smart grid cooperates with GaN inverters through CAN bus communication. At last, the three GaN inverters smart grid achieved the function of grid connected to islanded mode smooth transitionDissertation/ThesisDoctoral Dissertation Electrical Engineering 201

    Distributed photovoltaic systems: Utility interface issues and their present status. Intermediate/three-phase systems

    Get PDF
    The interface issues between the intermediate-size Power Conditioning Subsystem (PCS) and the utility are considered. A literature review yielded facts about the status of identified issues

    Energy Shaping Control for Stabilization of Interconnected Voltage Source Converters in Weakly-Connected AC Microgrid Systems

    Get PDF
    With the ubiquitous installations of renewable energy resources such as solar and wind, for decentralized power applications across the United States, microgrids are being viewed as an avenue for achieving this goal. Various independent system operators and regional transmission operators such as Southwest Power Pool (SPP), Midcontinent System Operator (MISO), PJM Interconnection and Electric Reliability Council of Texas (ERCOT) manage the transmission and generation systems that host the distributed energy resources (DERs). Voltage source converters typically interconnect the DERs to the utility system and used in High voltage dc (HVDC) systems for transmitting power throughout the United States. A microgrid configuration is built at the 13.8kV 4.75MVA National Center for Reliable Energy Transmission (NCREPT) testing facility for performing grid-connected and islanded operation of interconnected voltage source converters. The interconnected voltage source converters consist of a variable voltage variable frequency (VVVF) drive, which powers a regenerative (REGEN) load bench acting as a distributed energy resource emulator. Due to the weak-grid interface in islanded mode testing, a voltage instability occurs on the VVVF dc link voltage causing the system to collapse. This dissertation presents a new stability theorem for stabilizing interconnected voltage source converters in microgrid systems with weak-grid interfaces. The new stability theorem is derived using the concepts of Dirac composition in Port-Hamiltonian systems, passivity in physical systems, eigenvalue analysis and robust analysis based on the edge theorem for parametric uncertainty. The novel stability theorem aims to prove that all members of the classes of voltage source converter-based microgrid systems can be stabilized using an energy-shaping control methodology. The proposed theorems and stability analysis justifies the development of the Modified Interconnection and Damping Assignment Passivity-Based Control (Modified IDA-PBC) method to be utilized in stabilizing the microgrid configuration at NCREPT for mitigating system instabilities. The system is simulated in MATLAB/SimulinkTM using the Simpower toolbox to observe the system’s performance of the designed controller in comparison to the decoupled proportional intergral controller. The simulation results verify that the Modified-IDA-PBC is a viable option for dc bus voltage control of interconnected voltage source converters in microgrid systems