845 research outputs found

    A Scale-Space Medialness Transform Based on Boundary Concordance Voting

    Get PDF
    The Concordance-based Medial Axis Transform (CMAT) presented in this paper is a multiscale medial axis (MMA) algorithm that computes the medial response from grey-level boundary measures. This non-linear operator responds only to symmetric structures, overcoming the limitations of linear medial operators which create “side-lobe” responses for symmetric structures and respond to edge structures. In addition, the spatial localisation of the medial axis and the identification of object width is improved in the CMAT algorithm compared with linear algorithms. The robustness of linear medial operators to noise is preserved in our algorithm. The effectiveness of the CMAT is accredited to the concordance property described in this paper. We demonstrate the performance of this method with test figures used by other authors and medical images that are relatively complex in structure. In these complex images the benefit of the improved response of our non-linear operator is clearly visible

    Investigating the effect of drug release on in-stent restenosis: A hybrid continuum – agent-based modelling approach

    Get PDF
    Background and objective: In-stent restenosis (ISR) following percutaneous coronary intervention with drug-eluting stent (DES) implantation remains an unresolved issue, with ISR rates up to 10%. The use of antiproliferative drugs on DESs has significantly reduced ISR. However, a complete knowledge of the mechanobiological processes underlying ISR is still lacking. Multiscale agent-based modelling frameworks, integrating continuum- and agent-based approaches, have recently emerged as promising tools to decipher the mechanobiological events driving ISR at different spatiotemporal scales. However, the integration of sophisticated drug models with an agent-based model (ABM) of ISR has been under-investigated. The aim of the present study was to develop a novel multiscale agent-based modelling framework of ISR following DES implantation. Methods: The framework consisted of two bi-directionally coupled modules, namely (i) a drug transport module, simulating drug transport through a continuum-based approach, and (ii) a tissue remodelling module, simulating cellular dynamics through an ABM. Receptor saturation (RS), defined as the fraction of target receptors saturated with drug, is used to mediate cellular activities in the ABM, since RS is widely regarded as a measure of drug efficacy. Three studies were performed to investigate different scenarios in terms of drug mass (DM), drug release profiles (RP), coupling schemes and idealized vs. patient-specific artery geometries. Results: The studies demonstrated the versatility of the framework and enabled exploration of the sensitivity to different settings, coupling modalities and geometries. As expected, changes in the DM, RP and coupling schemes illustrated a variation in RS over time, in turn affecting the ABM response. For example, combined small DM – fast RP led to similar ISR degrees as high DM – moderate RP (lumen area reduction of ∌13/17% vs. ∌30% without drug). The use of a patient-specific geometry with non-equally distributed struts resulted in a heterogeneous RS map, but did not remarkably impact the ABM response. Conclusion: The application to a patient-specific geometry highlights the potential of the framework to address complex realistic scenarios and lays the foundations for future research, including calibration and validation on patient datasets and the investigation of the effects of different plaque composition on the arterial response to DES

    Spline-based medial axis transform representation of binary images

    Get PDF
    Medial axes are well-known descriptors used for representing, manipulating, and compressing binary images. In this paper, we present a full pipeline for computing a stable and accurate piece-wise B-spline representation of Medial Axis Transforms (MATs) of binary images. A comprehensive evaluation on a benchmark shows that our method, called Spline-based Medial Axis Transform (SMAT), achieves very high compression ratios while keeping quality high. Compared with the regular MAT representation, the SMAT yields a much higher compression ratio at the cost of a slightly lower image quality. We illustrate our approach on a multi-scale SMAT representation, generating super-resolution images, and free-form binary image deformation

    Steerable3D: An ImageJ plugin for neurovascular enhancement in 3-D segmentation

    Get PDF
    PurposeImage processing plays a fundamental role in the study of central nervous system, for example in the analysis of the vascular network in neurodegenerative diseases. Synchrotron X-ray Phase-contrast micro-Tomography (SXPCT) is a very attractive method to study weakly absorbing samples and features, such as the vascular network in the spinal cord (SC). However, the identification and segmentation of vascular structures in SXPCT images is seriously hampered by the presence of image noise and strong contrast inhomogeneities, due to the sensitivity of the technique to small electronic density variations. In order to help with these tasks, we implemented a user-friendly ImageJ plugin based on a 3D Gaussian steerable filter, tuned up for the enhancement of tubular structures in SXPCT images.MethodsThe developed 3D Gaussian steerable filter plugin for ImageJ is based on the steerability properties of Gaussian derivatives. We applied it to SXPCT images of ex-vivo mouse SCs acquired at different experimental conditions.ResultsThe filter response shows a strong amplification of the source image contrast-to-background ratio (CBR), independently of structures orientation. We found that after the filter application, the CBR ratio increases by a factor ranging from ~6 to ~60. In addition, we also observed an increase of 35% of the contrast to noise ratio in the case of injured mouse SC.ConclusionThe developed tool can generally facilitate the detection/segmentation of capillaries, veins and arteries that were not clearly observable in non-filtered SXPCT images. Its systematic application could allow obtaining quantitative information from pre-clinical and clinical images

    Grey matter sublayer thickness estimation in the mouse cerebellum

    Get PDF
    The cerebellar grey matter morphology is an important feature to study neurodegenerative diseases such as Alzheimer’s disease or Down’s syndrome. Its volume or thickness is commonly used as a surrogate imaging biomarker for such diseases. Most studies about grey matter thickness estimation focused on the cortex, and little attention has been drawn on the morphology of the cerebellum. Using ex vivo highresolution MRI, it is now possible to visualise the different cell layers in the mouse cerebellum. In this work, we introduce a framework to extract the Purkinje layer within the grey matter, enabling the estimation of the thickness of the cerebellar grey matter, the granular layer and molecular layer from gadolinium-enhanced ex vivo mouse brain MRI. Application to mouse model of Down’s syndrome found reduced cortical and layer thicknesses in the transchromosomic group

    Three-dimensional Quasi-Static Displacement of Human Middle-ear Ossicles under Static Pressure Loads: Measurement Using a Stereo Camera System

    Full text link
    The time delay and/or malfunctioning of the Eustachian tube may cause pressure differences across the tympanic membrane, resulting in quasi-static movements of the middle-ear ossicles. While quasi-static displacements of the human middle-ear ossicles have been measured one- or two-dimensionally in previous studies, this study presents an approach to trace three-dimensional movements of the human middle-ear ossicles under static pressure loads in the ear canal (EC). The three-dimensional quasi-static movements of the middle-ear ossicles were measured using a custom-made stereo camera system. Two cameras were assembled with a relative angle of 7 degrees and then mounted onto a robot arm. Red fluorescent beads of a 106-125 ”m diameter were placed on the middle-ear ossicles, and quasi-static position changes of the fluorescent beads under static pressure loads were traced by the stereo camera system. All the position changes of the ossicles were registered to the anatomical intrinsic frame based on the stapes footplate, which was obtained from ”-CT imaging. Under negative ear-canal pressures, a rotational movement around the anterior-posterior axis was dominant for the malleus-incus complex, with small relative movements between the two ossicles. The stapes showed translation toward the lateral direction and rotation around the long axis of the stapes footplate. Under positive EC pressures, relative motion between the malleus and the incus at the IMJ became larger, reducing movements of the incus and stapes considerably and thus performing a protection function for the inner-ear structures. Three-dimensional tracing of the middle-ear ossicular chain provides a better understanding of the protection function of the human middle ear under static pressured loads as immediate responses without time delay. Keywords ambient pressure variation micro-computed tomography imaging middle-ear ossicles protection function quasi-static displacement static pressure static pressure loads stereo camera system three-dimensional displacemen
    • 

    corecore