541 research outputs found

    AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation: Validation and comparison of performance with commercially available software.

    Get PDF
    Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC), and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (

    Quantitative evaluation of artifact removal in real magnetoencephalogram signals with blind source separation

    Full text link
    The magnetoencephalogram (MEG) is contaminated with undesired signals, which are called artifacts. Some of the most important ones are the cardiac and the ocular artifacts (CA and OA, respectively), and the power line noise (PLN). Blind source separation (BSS) has been used to reduce the influence of the artifacts in the data. There is a plethora of BSS-based artifact removal approaches, but few comparative analyses. In this study, MEG background activity from 26 subjects was processed with five widespread BSS (AMUSE, SOBI, JADE, extended Infomax, and FastICA) and one constrained BSS (cBSS) techniques. Then, the ability of several combinations of BSS algorithm, epoch length, and artifact detection metric to automatically reduce the CA, OA, and PLN were quantified with objective criteria. The results pinpointed to cBSS as a very suitable approach to remove the CA. Additionally, a combination of AMUSE or SOBI and artifact detection metrics based on entropy or power criteria decreased the OA. Finally, the PLN was reduced by means of a spectral metric. These findings confirm the utility of BSS to help in the artifact removal for MEG background activity

    Motion Artifact Processing Techniques for Physiological Signals

    Get PDF
    The combination of reducing birth rate and increasing life expectancy continues to drive the demographic shift toward an ageing population and this is placing an ever-increasing burden on our healthcare systems. The urgent need to address this so called healthcare \time bomb" has led to a rapid growth in research into ubiquitous, pervasive and distributed healthcare technologies where recent advances in signal acquisition, data storage and communication are helping such systems become a reality. However, similar to recordings performed in the hospital environment, artifacts continue to be a major issue for these systems. The magnitude and frequency of artifacts can vary signicantly depending on the recording environment with one of the major contributions due to the motion of the subject or the recording transducer. As such, this thesis addresses the challenges of the removal of this motion artifact removal from various physiological signals. The preliminary investigations focus on artifact identication and the tagging of physiological signals streams with measures of signal quality. A new method for quantifying signal quality is developed based on the use of inexpensive accelerometers which facilitates the appropriate use of artifact processing methods as needed. These artifact processing methods are thoroughly examined as part of a comprehensive review of the most commonly applicable methods. This review forms the basis for the comparative studies subsequently presented. Then, a simple but novel experimental methodology for the comparison of artifact processing techniques is proposed, designed and tested for algorithm evaluation. The method is demonstrated to be highly eective for the type of artifact challenges common in a connected health setting, particularly those concerned with brain activity monitoring. This research primarily focuses on applying the techniques to functional near infrared spectroscopy (fNIRS) and electroencephalography (EEG) data due to their high susceptibility to contamination by subject motion related artifact. Using the novel experimental methodology, complemented with simulated data, a comprehensive comparison of a range of artifact processing methods is conducted, allowing the identication of the set of the best performing methods. A novel artifact removal technique is also developed, namely ensemble empirical mode decomposition with canonical correlation analysis (EEMD-CCA), which provides the best results when applied on fNIRS data under particular conditions. Four of the best performing techniques were then tested on real ambulatory EEG data contaminated with movement artifacts comparable to those observed during in-home monitoring. It was determined that when analysing EEG data, the Wiener lter is consistently the best performing artifact removal technique. However, when employing the fNIRS data, the best technique depends on a number of factors including: 1) the availability of a reference signal and 2) whether or not the form of the artifact is known. It is envisaged that the use of physiological signal monitoring for patient healthcare will grow signicantly over the next number of decades and it is hoped that this thesis will aid in the progression and development of artifact removal techniques capable of supporting this growth

    Evaluation Of Automated Eye Blink Artefact Removal Using Stacked Dense Autoencoder

    Get PDF
    The presence of artefacts in Electroencephalograph (EEG) signals can have a considerable impact on the information they portray. In this comparative study, the automated removal of eye blink artefacts using the constrained latent representation of a stacked dense autoencoders (SDAE) and comparing its ability to that of the manual independent component analysis (ICA) approach was evaluated. A comparative evaluation of 5 stacked dense autoencoder architectures lead to a chosen architecture for which the ability to automatically detect and remove eye blink artefacts were both statistically and humanistically evaluated. The ability of the stacked dense autoencoder was statistically evaluated with the manual approach of ICA using the correlation coefficient, a comparative affect on the SNR using both approaches and a humanistic evaluation using visual inspections of the components of the stacked dense autoencoder reconstruction to that of the post ICA reconstruction where an inverse RMSE allowed for a further statistical evaluation of this comparison. It was found that the stacked dense autoencoder was unable to reconstruct random signal segments in any meaningful capacity when compared to that of ICA

    Automatic Artifact Removal from Electroencephalogram Data Based on A Priori Artifact Information

    Get PDF

    Comparative analysis of TMS-EEG signal using different approaches in healthy subjects

    Get PDF
    openThe integration of transcranial magnetic stimulation with electroencephalography (TMS-EEG) represents a useful non-invasive approach to assess cortical excitability, plasticity and intra-cortical connectivity in humans in physiological and pathological conditions. However, biological and environmental noise sources can contaminate the TMS-evoked potentials (TEPs). Therefore, signal preprocessing represents a fundamental step in the analysis of these potentials and is critical to remove artefactual components while preserving the physiological brain activity. The objective of the present study is to evaluate the effects of different signal processing pipelines, (namely Leodori et al., Rogasch et al., Mutanen et al.) applied on TEPs recorded in five healthy volunteers after TMS stimulation of the primary motor cortex (M1) of the dominant hemisphere. These pipelines were used and compared to remove artifacts and improve the quality of the recorded signals, laying the foundation for subsequent analyses. Various algorithms, such as Independent Component Analysis (ICA), SOUND, and SSP-SIR, were used in each pipeline. Furthermore, after signal preprocessing, current localization was performed to map the TMS-induced neural activation in the cortex. This methodology provided valuable information on the spatial distribution of activity and further validated the effectiveness of the signal cleaning pipelines. Comparing the effects of the different pipelines on the same dataset, we observed considerable variability in how the pipelines affect various signal characteristics. We observed significant differences in the effects on signal amplitude and in the identification and characterisation of peaks of interest, i.e., P30, N45, P60, N100, P180. The identification and characteristics of these peaks showed variability, especially with regard to the early peaks, which reflect the cortical excitability of the stimulated area and are the more affected by biological and stimulation-related artifacts. Despite these differences, the topographies and source localisation, which are the most informative and useful in reconstructing signal dynamics, were consistent and reliable between the different pipelines considered. The results suggest that the existing methodologies for analysing TEPs produce different effects on the data, but are all capable of reproducing the dynamics of the signal and its components. Future studies evaluating different signal preprocessing methods in larger populations are needed to determine an appropriate workflow that can be shared through the scientific community, in order to make the results obtained in different centres comparable

    Detection and removal of eyeblink artifacts from EEG using wavelet analysis and independent component analysis

    Get PDF
    Electrical signals generated by brain activity that are measured by the electroencephalogram can be distorted by electrical activity originating from eyeblinks and eye movements. This thesis proposes a new technique to identify and remove eyeblink artifacts from EEG data. An algorithm using a combination of wavelet analysis and independent component analysis (ICA) is implemented to detect the temporal location of the eyeblink artifact and eliminate it without compromising the integrity of the primary EEG data. The discrete wavelet transform is performed on 10 second epochs of data to detect the occurrence of ocular artifact. ICA is used to separate out the independent components within the data and the temporal locations of the eyeblink are used to remove the artifact and reconstruct the EEG data without that source of distortion. The results obtained indicate that the technique implemented may be robust enough to effectively process EEG data and is capable of removing eyeblink artifacts successfully when they are prominent and the data does not contain a great deal of movement artifact. The results show an 88.68% detection rate, a false positive rate of 4.03%, and an 87.23% removal rate for all eyeblinks that were accurately detected. The statistics obtained compared favorably with work done by others in this field of investigation

    DEVELOPMENT OF AN ACCURATE SEIZURE DETECTION SYSTEM USING RANDOM FOREST CLASSIFIER WITH ICA BASED ARTIFACT REMOVAL ON EEG DATA

    Get PDF
    Abstract The creation of a reliable artifact removal and precise epileptic seizure identification system using Seina Scalp EEG data and cutting-edge machine learning techniques is presented in this paper. Random Forest classifier used for seizure classification, and independent component analysis (ICA) is used for artifact removal. Various artifacts, such as eye blinks, muscular activity, and environmental noise, are successfully recognized and removed from the EEG signals using ICA-based artifact removal, increasing the accuracy of the analysis that comes after. A precise distinction between seizure and non-seizure segments is made possible by the Random Forest Classifier, which was created expressly to capture the spatial and temporal patterns associated with epileptic seizures. Experimental evaluation of the Seina Scalp EEG Data demonstrates the excellent accuracy of our approach, achieving a 96% seizure identification rate A potential strategy for improving the accuracy and clinical utility of EEG-based epilepsy diagnosis is the merging of modern signal processing methods and deep learning algorithms

    Analysis of Small Muscle Movement Effects on EEG Signals

    Get PDF
    In this thesis, the artefactual effects of the small muscle movements were investigated. Upper frequency bands (30 Hz) of the EEG signal were extracted in order to investigate the artefactual effects of the small muscle movements. When the contamination level is high, the detection of the small muscle artifact can be made with the 92.2% accuracy. If these artifacts are really small such as a single finger movement, the detection accuracy decreases to 64%. But, the detection accuracy increases to 72% after removing the eye blink artifacts. The results of the classification support our hypothesis about the artefactual effects of the small muscle movements

    Pre-processing and Feature Extraction Techniques for EEGBCI Applications- A Review of Recent Research

    Get PDF
    The electrical waveforms generated by brain named electroencephalogram (EEG) signals, require certain special processing for using them as part of applications. EEG signals need special pre-processing to enable brain computer interfaces (BCI) capture essential details of the signal and use them for specific applications, including deriving decisions. In this paper, we focus on some of the recent works reported in the area of EEG pre-processing. Further, we discuss some of the reported works related to feature extraction of EEG signals for application in drowsiness detection and development of assistive technologies for persons with special need.Keywords: EEG signals, signal pre-processing, feature extraction, electroencephalography
    corecore