1,099 research outputs found

    A Review of Smart Materials in Tactile Actuators for Information Delivery

    Full text link
    As the largest organ in the human body, the skin provides the important sensory channel for humans to receive external stimulations based on touch. By the information perceived through touch, people can feel and guess the properties of objects, like weight, temperature, textures, and motion, etc. In fact, those properties are nerve stimuli to our brain received by different kinds of receptors in the skin. Mechanical, electrical, and thermal stimuli can stimulate these receptors and cause different information to be conveyed through the nerves. Technologies for actuators to provide mechanical, electrical or thermal stimuli have been developed. These include static or vibrational actuation, electrostatic stimulation, focused ultrasound, and more. Smart materials, such as piezoelectric materials, carbon nanotubes, and shape memory alloys, play important roles in providing actuation for tactile sensation. This paper aims to review the background biological knowledge of human tactile sensing, to give an understanding of how we sense and interact with the world through the sense of touch, as well as the conventional and state-of-the-art technologies of tactile actuators for tactile feedback delivery

    Pathological Tremor as a Mechanical System: Modeling and Control of Artificial Muscle-Based Tremor Suppression

    Get PDF
    Central nervous system disorders produce the undesired, approximately rhythmic movement of body parts known as pathological tremor. This undesired motion inhibits the patient\u27s ability to perform tasks of daily living and participate in society. Typical treatments are medications and deep brain stimulation surgery, both of which include risks, side effects, and varying efficacy. Since the pathophysiology of tremor is not well understood, empirical investigation drives tremor treatment development. This dissertation explores tremor from a mechanical systems perspective to work towards theory-driven treatment design. The primary negative outcome of pathological tremor is the undesired movement of body parts: mechanically suppressing this motion provides effective tremor treatment by restoring limb function. Unlike typical treatments, the mechanisms for mechanical tremor suppression are well understood: applying joint torques that oppose tremor-producing muscular torques will reduce tremor irrespective of central nervous system pathophysiology. However, a tremor suppression system must also consider voluntary movements. For example, mechanically constraining the arm in a rigid cast eliminates tremor motion, but also eliminates the ability to produce voluntary motions. Indeed, passive mechanical systems typically reduce tremor and voluntary motions equally due to the close proximity of their frequency content. Thus, mechanical tremor suppression requires active actuation to reduce tremor with minimal influence on voluntary motion. However, typical engineering actuators are rigid and bulky, preventing clinical implementations. This dissertation explores dielectric elastomers as tremor suppression actuators to improve clinical implementation potential of mechanical tremor suppression. Dielectric elastomers are often called artificial muscles due to their similar mechanical properties as human muscle; these similarities may enable relatively soft, low-profile implementations. The primary drawback of dielectric elastomers is their relatively low actuation levels compared to typical actuators. This research develops a tremor-active approach to dielectric elastomer-based tremor suppression. In a tremor-active approach, the actuators only actuate to oppose tremor, while the human motor system must overcome the passive actuator dynamics. This approach leverages the low mechanical impedance of dielectric elastomers to overcome their low actuation levels. Simulations with recorded tremor datasets demonstrate excellent and robust tremor suppression performance. Benchtop experiments validate the control approach on a scaled system. Since dielectric elastomers are not yet commercially available, this research quantifies the necessary dielectric elastomer parameters to enable clinical implementations and evaluates the potential of manufacturing approaches in the literature to achieve these parameters. Overall, tremor-active control using dielectric elastomers represents a promising alternative to medications and surgery. Such a system may achieve comparable tremor reduction as medications and deep brain stimulation with minimal risks and greater efficacy, but at the cost of increased patient effort to produce voluntary motions. Parallel advances in scaled dielectric elastomer manufacturing processes and high-voltage power electronics will enable consumer implementations. In addition to tremor suppression, this dissertation investigates the mechanisms of central nervous system tremor generation from a control systems perspective. This research investigates a delay-based model for parkinsonian tremor. Besides tremor, Parkinson\u27s disease generally inhibits movement, with typical symptoms including rigidity, bradykinesia, and increased reaction times. This fact raises the question as to how the same disease produces excessive movement (tremor) despite characteristically inhibiting movement. One possible answer is that excessive central nervous system inhibition produces unaccounted feedback delays that cause instability. This dissertation develops an optimal control model of human motor control with an unaccounted delay between the state estimator and controller. This delay represents the increased inhibition projected from the basal ganglia to the thalamus, delaying signals traveling from the cerebellum (estimator) to the primary motor cortex (controller). Model simulations show increased delays decrease tremor frequency and increase tremor amplitude, consistent with the evolution of tremor as the disease progresses. Simulations that incorporate tremor resetting and random variation in control saturation produce simulated tremor with similar characteristics as recorded tremor. Delay-induced tremor explains the effectiveness of deep brain stimulation in both the thalamus and basal ganglia since both regions contribute to the presence of feedback delay. Clinical evaluation of mechanical tremor suppression may provide clinical evidence for delay-induced tremor: unlike state-independent tremor, suppression of delay-induced tremor increases tremor frequency. Altogether, establishing the mechanisms for tremor generation will facilitate pathways towards improved treatments and cure development

    Optically Driven PH Gradient Generator Based on Self-Assembled Proton Pumps for Activating Hydrogel Microactuators

    Get PDF
    This dissertation presents a new approach for developing a biologically inspired photo-electro-chemo-mechanical microactuator by exploiting the ion pumping characteristics of bacteriorhodopsin (bR) proton pumps and the pH sensitivity of smart hydrogels. The ultimate goal of this project is to prove the viability of integrating bR monolayer into novel actuation applications using molecular level architectures. To accomplish this, the bR proton pumps are molecularly labelled, organized, and directionally immobilized on Au-coated substrate, and then integrated with pH sensitive hydrogel. When responding to an incident light beams, the internal proton pumping mechanism is mathematically modeled for quantifying the processing of the photonic energy into electro-chemical potential. Experimental and theoretical findings indicate that the photo-electric response of the dry bR is attributed to charge displacement and recombination; whereas, the response of the aqueous bR measured is a real proton pumping mechanism. The photo-electric properties, light source conditions all have influence on the observed photo-electric response characteristics. The presented technology is proven both experimentally and analytically through simulation. Experiments are conducted using acrylic acid (AA) monomer linked to 2-hydroxyethyl methacrylate (HEMA) monomer and the developed bR monolayer forming this hybrid microactuator. The light detecting part of the actuator is the bR monolayer. In this part the incident light beams are processed in the bR proton pumps through their photo-cycle to transport protons from the cytoplasmic side to the extracellular side of the bR protein. The bR monolayer is fabricated with molecular level recognition, labelling, and adsorption leading to a novel architecture able to transport protons through a porous substrate. Once protons are transported from one side to the other side of the membrane, the concentration of the hydrogen ions is changed. The change in the hydrogen ions concentration is expected theoretically and has been proved by monitoring pH changes in the ionic solution as pH gives direct indication on the hydrogen ions concentration. The change in the pH is exploited by integrating the light detecting part of the actuator to the pH-sensitive hydrogel which acts as the actuator shell that receives the pH changes and treat it as an input signal and then process it to undergo in an electric phase transition that leads to volume transition and associated mechanical work. The generated mechanical work is exploited in microactuation techniques with interest in microfluidic valves to control the flow in the microchannels. Based on the presented work the bR monolayer shows great potential for becoming a viable biomaterial for use in optical sensing and actuation. Many industrial and biomedical applications may benefit from the presented advances in generating higher performance micro-systems

    Soft Gloves: A Review on Recent Developments in Actuation, Sensing, Control and Applications

    Get PDF
    Interest in soft gloves, both robotic and haptic, has enormously grown over the past decade, due to their inherent compliance, which makes them particularly suitable for direct interaction with the human hand. Robotic soft gloves have been developed for hand rehabilitation, for ADLs assistance, or sometimes for both. Haptic soft gloves may be applied in virtual reality (VR) applications or to give sensory feedback in combination with prostheses or to control robots. This paper presents an updated review of the state of the art of soft gloves, with a particular focus on actuation, sensing, and control, combined with a detailed analysis of the devices according to their application field. The review is organized on two levels: a prospective review allows the highlighting of the main trends in soft gloves development and applications, and an analytical review performs an in-depth analysis of the technical solutions developed and implemented in the revised scientific research. Additional minor evaluations integrate the analysis, such as a synthetic investigation of the main results in the clinical studies and trials referred in literature which involve soft gloves

    MEMS Accelerometers

    Get PDF
    Micro-electro-mechanical system (MEMS) devices are widely used for inertia, pressure, and ultrasound sensing applications. Research on integrated MEMS technology has undergone extensive development driven by the requirements of a compact footprint, low cost, and increased functionality. Accelerometers are among the most widely used sensors implemented in MEMS technology. MEMS accelerometers are showing a growing presence in almost all industries ranging from automotive to medical. A traditional MEMS accelerometer employs a proof mass suspended to springs, which displaces in response to an external acceleration. A single proof mass can be used for one- or multi-axis sensing. A variety of transduction mechanisms have been used to detect the displacement. They include capacitive, piezoelectric, thermal, tunneling, and optical mechanisms. Capacitive accelerometers are widely used due to their DC measurement interface, thermal stability, reliability, and low cost. However, they are sensitive to electromagnetic field interferences and have poor performance for high-end applications (e.g., precise attitude control for the satellite). Over the past three decades, steady progress has been made in the area of optical accelerometers for high-performance and high-sensitivity applications but several challenges are still to be tackled by researchers and engineers to fully realize opto-mechanical accelerometers, such as chip-scale integration, scaling, low bandwidth, etc

    Energy harvesting from body motion using rotational micro-generation

    Get PDF
    Autonomous system applications are typically limited by the power supply operational lifetime when battery replacement is difficult or costly. A trade-off between battery size and battery life is usually calculated to determine the device capability and lifespan. As a result, energy harvesting research has gained importance as society searches for alternative energy sources for power generation. For instance, energy harvesting has been a proven alternative for powering solar-based calculators and self-winding wristwatches. Thus, the use of energy harvesting technology can make it possible to assist or replace batteries for portable, wearable, or surgically-implantable autonomous systems. Applications such as cardiac pacemakers or electrical stimulation applications can benefit from this approach since the number of surgeries for battery replacement can be reduced or eliminated. Research on energy scavenging from body motion has been investigated to evaluate the feasibility of powering wearable or implantable systems. Energy from walking has been previously extracted using generators placed on shoes, backpacks, and knee braces while producing power levels ranging from milliwatts to watts. The research presented in this paper examines the available power from walking and running at several body locations. The ankle, knee, hip, chest, wrist, elbow, upper arm, side of the head, and back of the head were the chosen target localizations. Joints were preferred since they experience the most drastic acceleration changes. For this, a motor-driven treadmill test was performed on 11 healthy individuals at several walking (1-4 mph) and running (2-5 mph) speeds. The treadmill test provided the acceleration magnitudes from the listed body locations. Power can be estimated from the treadmill evaluation since it is proportional to the acceleration and frequency of occurrence. Available power output from walking was determined to be greater than 1mW/cm³ for most body locations while being over 10mW/cm³ at the foot and ankle locations. Available power from running was found to be almost 10 times higher than that from walking. Most energy harvester topologies use linear generator approaches that are well suited to fixed-frequency vibrations with sub-millimeter amplitude oscillations. In contrast, body motion is characterized with a wide frequency spectrum and larger amplitudes. A generator prototype based on self-winding wristwatches is deemed to be appropriate for harvesting body motion since it is not limited to operate at fixed-frequencies or restricted displacements. Electromagnetic generation is typically favored because of its slightly higher power output per unit volume. Then, a nonharmonic oscillating rotational energy scavenger prototype is proposed to harness body motion. The electromagnetic generator follows the approach from small wind turbine designs that overcome the lack of a gearbox by using a larger number of coil and magnets arrangements. The device presented here is composed of a rotor with multiple-pole permanent magnets having an eccentric weight and a stator composed of stacked planar coils. The rotor oscillations induce a voltage on the planar coil due to the eccentric mass unbalance produced by body motion. A meso-scale prototype device was then built and evaluated for energy generation. The meso-scale casing and rotor were constructed on PMMA with the help of a CNC mill machine. Commercially available discrete magnets were encased in a 25mm rotor. Commercial copper-coated polyimide film was employed to manufacture the planar coils using MEMS fabrication processes. Jewel bearings were used to finalize the arrangement. The prototypes were also tested at the listed body locations. A meso-scale generator with a 2-layer coil was capable to extract up to 234 µW of power at the ankle while walking at 3mph with a 2cm³ prototype for a power density of 117 µW/cm³. This dissertation presents the analysis of available power from walking and running at different speeds and the development of an unobtrusive miniature energy harvesting generator for body motion. Power generation indicates the possibility of powering devices by extracting energy from body motion

    A Review of Cooperative Actuator and Sensor Systems Based on Dielectric Elastomer Transducers

    Get PDF
    This paper presents an overview of cooperative actuator and sensor systems based on dielectric elastomer (DE) transducers. A DE consists of a flexible capacitor made of a thin layer of soft dielectric material (e.g., acrylic, silicone) surrounded with a compliant electrode, which is able to work as an actuator or as a sensor. Features such as large deformation, high compliance, flexibility, energy efficiency, lightweight, self-sensing, and low cost make DE technology particularly attractive for the realization of mechatronic systems that are capable of performance not achievable with alternative technologies. If several DEs are arranged in an array-like configuration, new concepts of cooperative actuator/sensor systems can be enabled, in which novel applications and features are made possible by the synergistic operations among nearby elements. The goal of this paper is to review recent advances in the area of cooperative DE systems technology. After summarizing the basic operating principle of DE transducers, several applications of cooperative DE actuators and sensors from the recent literature are discussed, ranging from haptic interfaces and bio-inspired robots to micro-scale devices and tactile sensors. Finally, challenges and perspectives for the future development of cooperative DE systems are discussed
    • …
    corecore