77 research outputs found

    Computer Aided Detection of Microcalcifications Utilizing Texture Analysis

    Get PDF
    A comparative study of texture measures for the classification of breast tissue is presented. The texture features investigated include Angular Second Moments, Power Spectrum Analysis and a novel feature, Laws Energy Ratios. The texture study was accomplished as part of the development of a Model Based Vision (MBV) system for the automatic detection of microcalcifications. An overview of the Microcalcification Detection System is presented, which applies image differencing techniques, feature selection methods, and neural networks for locating microcalcification clusters in mammograms. The Power Spectrum Analysis feature set had the best overall performance with an 83% Probability of Detection and an average False ROl Rate of 2.17 ROIs per image over 53 mammograms. A combination of Laws Energy Ratio and Power Spectrum Analysis features selected using Ruck Saliency metrics achieved an increased Probability of Detection of 85% with an average 4 false ROIs per image

    Mammography

    Get PDF
    In this volume, the topics are constructed from a variety of contents: the bases of mammography systems, optimization of screening mammography with reference to evidence-based research, new technologies of image acquisition and its surrounding systems, and case reports with reference to up-to-date multimodality images of breast cancer. Mammography has been lagged in the transition to digital imaging systems because of the necessity of high resolution for diagnosis. However, in the past ten years, technical improvement has resolved the difficulties and boosted new diagnostic systems. We hope that the reader will learn the essentials of mammography and will be forward-looking for the new technologies. We want to express our sincere gratitude and appreciation?to all the co-authors who have contributed their work to this volume

    Automatic BIRAD scoring of breast cancer mammograms

    Get PDF
    A computer aided diagnosis system (CAD) is developed to fully characterize and classify mass to benign and malignancy and to predict BIRAD (Breast Imaging Reporting and Data system) scores using mammographic image data. The CAD includes a preprocessing step to de-noise mammograms. This is followed by an active counter segmentation to deforms an initial curve, annotated by a radiologist, to separate and define the boundary of a mass from background. A feature extraction scheme wasthen used to fully characterize a mass by extraction of the most relevant features that have a large impact on the outcome of a patient biopsy. For this thirty-five medical and mathematical features based on intensity, shape and texture associated to the mass were extracted. Several feature selection schemes were then applied to select the most dominant features for use in next step, classification. Finally, a hierarchical classification schemes were applied on those subset of features to firstly classify mass to benign (mass with BIRAD score 2) and malignant mass (mass with BIRAD score over 4), and secondly to sub classify mass with BIRAD score over 4 to three classes (BIRAD with score 4a,4b,4c). Accuracy of segmentation performance were evaluated by calculating the degree of overlapping between the active counter segmentation and the manual segmentation, and the result was 98.5%. Also reproducibility of active counter 3 using different manual initialization of algorithm by three radiologists were assessed and result was 99.5%. Classification performance was evaluated using one hundred sixty masses (80 masses with BRAD score 2 and 80 mass with BIRAD score over4). The best result for classification of data to benign and malignance was found using a combination of sequential forward floating feature (SFFS) selection and a boosted tree hybrid classifier with Ada boost ensemble method, decision tree learner type and 100 learners’ regression tree classifier, achieving 100% sensitivity and specificity in hold out method, 99.4% in cross validation method and 98.62 % average accuracy in cross validation method. For further sub classification of eighty malignance data with BIRAD score of over 4 (30 mass with BIRAD score 4a,30 masses with BIRAD score 4b and 20 masses with BIRAD score 4c), the best result achieved using the boosted tree with ensemble method bag, decision tree learner type with 200 learners Classification, achieving 100% sensitivity and specificity in hold out method, 98.8% accuracy and 98.41% average accuracy for ten times run in cross validation method. Beside those 160 masses (BIRAD score 2 and over 4) 13 masses with BIRAD score 3 were gathered. Which means patient is recommended to be tested in another medical imaging technique and also is recommended to do follow-up in six months. The CAD system was trained with mass with BIRAD score 2 and over 4 also 4 it was further tested using 13 masses with a BIRAD score of 3 and the CAD results are shown to agree with the radiologist’s classification after confirming in six months follow up. The present results demonstrate high sensitivity and specificity of the proposed CAD system compared to prior research. The present research is therefore intended to make contributions to the field by proposing a novel CAD system, consists of series of well-selected image processing algorithms, to firstly classify mass to benign or malignancy, secondly sub classify BIRAD 4 to three groups and finally to interpret BIRAD 3 to BIRAD 2 without a need of follow up study

    Computer-aided detection and diagnosis of breast cancer in 2D and 3D medical imaging through multifractal analysis

    Get PDF
    This Thesis describes the research work performed in the scope of a doctoral research program and presents its conclusions and contributions. The research activities were carried on in the industry with Siemens S.A. Healthcare Sector, in integration with a research team. Siemens S.A. Healthcare Sector is one of the world biggest suppliers of products, services and complete solutions in the medical sector. The company offers a wide selection of diagnostic and therapeutic equipment and information systems. Siemens products for medical imaging and in vivo diagnostics include: ultrasound, computer tomography, mammography, digital breast tomosynthesis, magnetic resonance, equipment to angiography and coronary angiography, nuclear imaging, and many others. Siemens has a vast experience in Healthcare and at the beginning of this project it was strategically interested in solutions to improve the detection of Breast Cancer, to increase its competitiveness in the sector. The company owns several patents related with self-similarity analysis, which formed the background of this Thesis. Furthermore, Siemens intended to explore commercially the computer- aided automatic detection and diagnosis eld for portfolio integration. Therefore, with the high knowledge acquired by University of Beira Interior in this area together with this Thesis, will allow Siemens to apply the most recent scienti c progress in the detection of the breast cancer, and it is foreseeable that together we can develop a new technology with high potential. The project resulted in the submission of two invention disclosures for evaluation in Siemens A.G., two articles published in peer-reviewed journals indexed in ISI Science Citation Index, two other articles submitted in peer-reviewed journals, and several international conference papers. This work on computer-aided-diagnosis in breast led to innovative software and novel processes of research and development, for which the project received the Siemens Innovation Award in 2012. It was very rewarding to carry on such technological and innovative project in a socially sensitive area as Breast Cancer.No cancro da mama a deteção precoce e o diagnóstico correto são de extrema importância na prescrição terapêutica e caz e e ciente, que potencie o aumento da taxa de sobrevivência à doença. A teoria multifractal foi inicialmente introduzida no contexto da análise de sinal e a sua utilidade foi demonstrada na descrição de comportamentos siológicos de bio-sinais e até na deteção e predição de patologias. Nesta Tese, três métodos multifractais foram estendidos para imagens bi-dimensionais (2D) e comparados na deteção de microcalci cações em mamogramas. Um destes métodos foi também adaptado para a classi cação de massas da mama, em cortes transversais 2D obtidos por ressonância magnética (RM) de mama, em grupos de massas provavelmente benignas e com suspeição de malignidade. Um novo método de análise multifractal usando a lacunaridade tri-dimensional (3D) foi proposto para classi cação de massas da mama em imagens volumétricas 3D de RM de mama. A análise multifractal revelou diferenças na complexidade subjacente às localizações das microcalci cações em relação aos tecidos normais, permitindo uma boa exatidão da sua deteção em mamogramas. Adicionalmente, foram extraídas por análise multifractal características dos tecidos que permitiram identi car os casos tipicamente recomendados para biópsia em imagens 2D de RM de mama. A análise multifractal 3D foi e caz na classi cação de lesões mamárias benignas e malignas em imagens 3D de RM de mama. Este método foi mais exato para esta classi cação do que o método 2D ou o método padrão de análise de contraste cinético tumoral. Em conclusão, a análise multifractal fornece informação útil para deteção auxiliada por computador em mamogra a e diagnóstico auxiliado por computador em imagens 2D e 3D de RM de mama, tendo o potencial de complementar a interpretação dos radiologistas
    • …
    corecore