247 research outputs found

    Current and Future Trends in Magnetic Resonance Imaging Assessments of the Response of Breast Tumors to Neoadjuvant Chemotherapy

    Get PDF
    The current state-of-the-art assessment of treatment response in breast cancer is based on the response evaluation criteria in solid tumors (RECIST). RECIST reports on changes in gross morphology and divides response into one of four categories. In this paper we highlight how dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted MRI (DW-MRI) may be able to offer earlier, and more precise, information on treatment response in the neoadjuvant setting than RECIST. We then describe how longitudinal registration of breast images and the incorporation of intelligent bioinformatics approaches with imaging data have the potential to increase the sensitivity of assessing treatment response. We conclude with a discussion of the potential benefits of breast MRI at the higher field strength of 3T. For each of these areas, we provide a review, illustrative examples from clinical trials, and offer insights into future research directions

    A Simple Regularizer for B-spline Nonrigid Image Registration That Encourages Local Invertibility

    Full text link
    Nonrigid image registration is an important task for many medical imaging applications. In particular, for radiation oncology it is desirable to track respiratory motion for thoracic cancer treatment. B-splines are convenient for modeling nonrigid deformations, but ensuring invertibility can be a challenge. This paper describes sufficient conditions for local invertibility of deformations based on B-spline bases. These sufficient conditions can be used with constrained optimization to enforce local invertibility. We also incorporate these conditions into nonrigid image registration methods based on a simple penalty approach that encourages diffeomorphic deformations. Traditional Jacobian penalty methods penalize negative Jacobian determinant values only at grid points. In contrast, our new method enforces a sufficient condition for invertibility directly on the deformation coefficients to encourage invertibility globally over a 3-D continuous domain. The proposed penalty approach requires substantially less compute time than Jacobian penalties per iteration.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85951/1/Fessler21.pd

    A Simple Penalty that Encourages Local Invertibility and Considers Sliding Effects for Respiratory Motion

    Full text link
    Nonrigid image registration is a key tool in medical imaging. Because of high degrees of freedom in nonrigid transforms, there have been many efforts to regularize the deformation based on some reasonable assumptions. Especially, motion invertibility and local tissue rigidity have been investigated as reasonable priors in image registration. There have been several papers on exploiting each constraint separately. These constraints are reasonable in respiratory motion estimation because breathing motion is invertible and there are some rigid structures such as bones. Using both constraints seems very attractive in respiratory motion registration since using invertibility prior alone usually causes bone warping in ribs. Using rigidity prior seems natural and straightforward. However, the “sliding effect” near the interface between rib cage and diaphragm makes problem harder because it is not locally invertible. In this area, invertibility and rigidity priors have opposite forces. Recently, we proposed a simple piecewise quadratic penalty that encourages the local invertibility of motions. In this work we relax this penalty function by using a Geman-type function that allows the deformation to be piecewise smooth instead of globally smooth. This allows the deformation to be discontinuous in the area of the interface between rib cage and diaphragm. With some small sacrifice of regularity, we could achieve more realistic discontinuous motion near diaphragm, better data fitting error as well as less bone warping. We applied this Geman-type function penalty only to the x- and y-direction partial derivatives of the z-direction deformation to address the sliding effect. 192 × 128 × 128 3D CT inhale and exhale images of a real patient were used to show the benefits of this new penalty method.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85922/1/Fessler238.pd

    The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry

    Get PDF
    Objectives: To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry. Methods: The effect of image feature content, image contrast, noise, and BKS on the spatial accuracy of a B-spline DIR was studied. Phantom images were created with varying feature content and varying contrast-to-noise ratio (CNR), and deformed using a known smooth B-spline deformation. Subsequently, the deformed images were repeatedly registered with the original images using different BKSs. The quality of the DIR was expressed as the mean residual displacement (MRD) between the known imposed deformation and the result of the B-spline DIR. Finally, for three patients, head-and-neck planning CT scans were deformed with a realistic deformation field derived from a rescan CT of the same patient, resulting in a simulated deformed image and an a-priori known deformation field. Hence, a B-spline DIR was performed between the simulated image and the planning CT at different BKSs. Similar to the phantom cases, the DIR accuracy was evaluated by means of MRD. Results: In total, 162 phantom registrations were performed with varying CNR and BKSs. MRD-values = +/- 250 HU and noise <+/- 200 HU. Decreasing the image feature content resulted in increased MRD-values at all BKSs. Using BKS = 15 mm for the three clinical cases resulted in an average MRD <1.0 mm. Conclusions: For synthetically generated phantoms and three real CT cases the highest DIR accuracy was obtained for a BKS between 10-20 mm. The accuracy decreased with decreasing image feature content, decreasing image contrast, and higher noise levels. Our results indicate that DIR accuracy in clinical CT images (typical noise levels <+/- 100 HU) will not be effected by the amount of image noise

    Development of Efficient Intensity Based Registration Techniques for Multi-modal Brain Images

    Get PDF
    Recent advances in medical imaging have resulted in the development of many imaging techniques that capture various aspects of the patients anatomy and metabolism. These are accomplished with image registration: the task of transforming images on a common anatomical coordinate space. Image registration is one of the important task for multi-modal brain images, which has paramount importance in clinical diagnosis, leads to treatment of brain diseases. In many other applications, image registration characterizes anatomical variability, to detect changes in disease state over time, and by mapping functional information into anatomical space. This thesis is focused to explore intensity-based registration techniques to accomplish precise information with accurate transformation for multi-modal brain images. In this view, we addressed mainly three important issues of image registration both in the rigid and non-rigid framework, i.e. i) information theoretic based similarity measure for alignment measurement, ii) free form deformation (FFD) based transformation, and iii) evolutionary technique based optimization of the cost function. Mutual information (MI) is a widely used information theoretic similarity measure criterion for multi-modal brain image registration. MI only dense the quantitative aspects of information based on the probability of events. For rustication of the information of events, qualitative aspect i.e. utility or saliency is a necessitate factor for consideration. In this work, a novel similarity measure is proposed, which incorporates the utility information into mutual Information, known as Enhanced Mutual Information(EMI).It is found that the maximum information gain using EMI is higher as compared to that of other state of arts. The utility or saliency employed in EMI is a scale invariant parameter, and hence it may fail to register in case of projective and perspective transformations. To overcome this bottleneck, salient region (SR) based Enhance Mutual Information (SR-EMI)is proposed, a new similarity measure for robust and accurate registration. The proposed SR-EMI based registration technique is robust to register the multi-modal brain images at a faster rate with better alignment

    Automatic motion compensation of free breathing acquired myocardial perfusion data by using independent component analysis

    Full text link
    Images acquired during free breathing using first-pass gadolinium-enhanced myocardial perfusion magnetic resonance imaging (MRI) exhibit a quasiperiodic motion pattern that needs to be compensated for if a further automatic analysis of the perfusion is to be executed. In this work, we present a method to compensate this movement by combining independent component analysis (ICA) and image registration: First, we use ICA and a time?frequency analysis to identify the motion and separate it from the intensity change induced by the contrast agent. Then, synthetic reference images are created by recombining all the independent components but the one related to the motion. Therefore, the resulting image series does not exhibit motion and its images have intensities similar to those of their original counterparts. Motion compensation is then achieved by using a multi-pass image registration procedure. We tested our method on 39 image series acquired from 13 patients, covering the basal, mid and apical areas of the left heart ventricle and consisting of 58 perfusion images each. We validated our method by comparing manually tracked intensity profiles of the myocardial sections to automatically generated ones before and after registration of 13 patient data sets (39 distinct slices). We compared linear, non-linear, and combined ICA based registration approaches and previously published motion compensation schemes. Considering run-time and accuracy, a two-step ICA based motion compensation scheme that first optimizes a translation and then for non-linear transformation performed best and achieves registration of the whole series in 32 ± 12 s on a recent workstation. The proposed scheme improves the Pearsons correlation coefficient between manually and automatically obtained time?intensity curves from .84 ± .19 before registration to .96 ± .06 after registratio
    corecore