9,076 research outputs found
Fractal Descriptors in the Fourier Domain Applied to Color Texture Analysis
The present work proposes the development of a novel method to provide
descriptors for colored texture images. The method consists in two steps. In
the first, we apply a linear transform in the color space of the image aiming
at highlighting spatial structuring relations among the color of pixels. In a
second moment, we apply a multiscale approach to the calculus of fractal
dimension based on Fourier transform. From this multiscale operation, we
extract the descriptors used to discriminate the texture represented in digital
images. The accuracy of the method is verified in the classification of two
color texture datasets, by comparing the performance of the proposed technique
to other classical and state-of-the-art methods for color texture analysis. The
results showed an advantage of almost 3% of the proposed technique over the
second best approach.Comment: Chaos, Volume 21, Issue 4, 201
Gabor Barcodes for Medical Image Retrieval
In recent years, advances in medical imaging have led to the emergence of
massive databases, containing images from a diverse range of modalities. This
has significantly heightened the need for automated annotation of the images on
one side, and fast and memory-efficient content-based image retrieval systems
on the other side. Binary descriptors have recently gained more attention as a
potential vehicle to achieve these goals. One of the recently introduced binary
descriptors for tagging of medical images are Radon barcodes (RBCs) that are
driven from Radon transform via local thresholding. Gabor transform is also a
powerful transform to extract texture-based information. Gabor features have
exhibited robustness against rotation, scale, and also photometric
disturbances, such as illumination changes and image noise in many
applications. This paper introduces Gabor Barcodes (GBCs), as a novel framework
for the image annotation. To find the most discriminative GBC for a given query
image, the effects of employing Gabor filters with different parameters, i.e.,
different sets of scales and orientations, are investigated, resulting in
different barcode lengths and retrieval performances. The proposed method has
been evaluated on the IRMA dataset with 193 classes comprising of 12,677 x-ray
images for indexing, and 1,733 x-rays images for testing. A total error score
as low as ( accuracy for the first hit) was achieved.Comment: To appear in proceedings of The 2016 IEEE International Conference on
Image Processing (ICIP 2016), Sep 25-28, 2016, Phoenix, Arizona, US
Histopathological image analysis : a review
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches to radiological data. With the recent advent of whole slide digital scanners, tissue histopathology slides can now be digitized and stored in digital image form. Consequently, digitized tissue histopathology has now become amenable to the application of computerized image analysis and machine learning techniques. Analogous to the role of computer-assisted diagnosis (CAD) algorithms in medical imaging to complement the opinion of a radiologist, CAD algorithms have begun to be developed for disease detection, diagnosis, and prognosis prediction to complement the opinion of the pathologist. In this paper, we review the recent state of the art CAD technology for digitized histopathology. This paper also briefly describes the development and application of novel image analysis technology for a few specific histopathology related problems being pursued in the United States and Europe
Computer-Assisted Algorithms for Ultrasound Imaging Systems
Ultrasound imaging works on the principle of transmitting ultrasound waves into the body and
reconstructs the images of internal organs based on the strength of the echoes. Ultrasound imaging
is considered to be safer, economical and can image the organs in real-time, which makes it widely
used diagnostic imaging modality in health-care. Ultrasound imaging covers the broad spectrum
of medical diagnostics; these include diagnosis of kidney, liver, pancreas, fetal monitoring, etc.
Currently, the diagnosis through ultrasound scanning is clinic-centered, and the patients who are
in need of ultrasound scanning has to visit the hospitals for getting the diagnosis. The services of
an ultrasound system are constrained to hospitals and did not translate to its potential in remote
health-care and point-of-care diagnostics due to its high form factor, shortage of sonographers, low
signal to noise ratio, high diagnostic subjectivity, etc. In this thesis, we address these issues with an
objective of making ultrasound imaging more reliable to use in point-of-care and remote health-care
applications. To achieve the goal, we propose (i) computer-assisted algorithms to improve diagnostic
accuracy and assist semi-skilled persons in scanning, (ii) speckle suppression algorithms to improve
the diagnostic quality of ultrasound image, (iii) a reliable telesonography framework to address
the shortage of sonographers, and (iv) a programmable portable ultrasound scanner to operate in
point-of-care and remote health-care applications
Content based retrieval of PET neurological images
Medical image management has posed challenges to many researchers, especially when the images have to be indexed and retrieved using their visual content that is meaningful to clinicians. In this study, an image retrieval system has been developed for 3D brain PET (Position emission tomography) images. It has been found that PET neurological images can be retrieved based upon their diagnostic status using only data pertaining to their content, and predominantly the visual content.
During the study PET scans are spatially normalized, using existing techniques, and their visual data is quantified. The mid-sagittal-plane of each individual 3D PET scan is found and then utilized in the detection of abnormal asymmetries, such as tumours or physical injuries. All the asymmetries detected are referenced to the Talairarch and Tournoux anatomical atlas. The Cartesian co- ordinates in Talairarch space, of detected lesion, are employed along with the associated anatomical structure(s) as the indices within the content based image retrieval system. The anatomical atlas is then also utilized to isolate distinct anatomical areas that are related to a number of neurodegenerative disorders. After segmentation of the anatomical regions of interest algorithms are applied to characterize the texture of brain intensity using Gabor filters and to elucidate the mean index ratio of activation levels. These measurements are combined to produce a single feature vector that is incorporated into the content based image retrieval system.
Experimental results on images with known diagnoses show that physical lesions such as head injuries and tumours can be, to a certain extent, detected correctly. Images with correctly detected and measured lesion are then retrieved from the database of images when a query pertains to the measured locale. Images with neurodegenerative disorder patterns have been indexed and retrieved via texture-based features. Retrieval accuracy is increased, for images from patients diagnosed with dementia, by combining the texture feature and mean index ratio value
Application of Fractal Dimension for Quantifying Noise Texture in Computed Tomography Images
Purpose
Evaluation of noise texture information in CT images is important for assessing image quality. Noise texture is often quantified by the noise power spectrum (NPS), which requires numerous image realizations to estimate. This study evaluated fractal dimension for quantifying noise texture as a scalar metric that can potentially be estimated using one image realization. Methods
The American College of Radiology CT accreditation phantom (ACR) was scanned on a clinical scanner (Discovery CT750, GE Healthcare) at 120 kV and 25 and 90 mAs. Images were reconstructed using filtered back projection (FBP/ASIR 0%) with varying reconstruction kernels: Soft, Standard, Detail, Chest, Lung, Bone, and Edge. For each kernel, images were also reconstructed using ASIR 50% and ASIR 100% iterative reconstruction (IR) methods. Fractal dimension was estimated using the differential box‐counting algorithm applied to images of the uniform section of ACR phantom. The two‐dimensional Noise Power Spectrum (NPS) and one‐dimensional‐radially averaged NPS were estimated using established techniques. By changing the radiation dose, the effect of noise magnitude on fractal dimension was evaluated. The Spearman correlation between the fractal dimension and the frequency of the NPS peak was calculated. The number of images required to reliably estimate fractal dimension was determined and compared to the number of images required to estimate the NPS‐peak frequency. The effect of Region of Interest (ROI) size on fractal dimension estimation was evaluated. Feasibility of estimating fractal dimension in an anthropomorphic phantom and clinical image was also investigated, with the resulting fractal dimension compared to that estimated within the uniform section of the ACR phantom. Results
Fractal dimension was strongly correlated with the frequency of the peak of the radially averaged NPS curve, having a Spearman rank‐order coefficient of 0.98 (P‐value \u3c 0.01) for ASIR 0%. The mean fractal dimension at ASIR 0% was 2.49 (Soft), 2.51 (Standard), 2.52 (Detail), 2.57 (Chest), 2.61 (Lung), 2.66 (Bone), and 2.7 (Edge). A reduction in fractal dimension was observed with increasing ASIR levels for all investigated reconstruction kernels. Fractal dimension was found to be independent of noise magnitude. Fractal dimension was successfully estimated from four ROIs of size 64 × 64 pixels or one ROI of 128 × 128 pixels. Fractal dimension was found to be sensitive to non‐noise structures in the image, such as ring artifacts and anatomical structure. Fractal dimension estimated within a uniform region of an anthropomorphic phantom and clinical head image matched that estimated within the ACR phantom for filtered back projection reconstruction. Conclusions
Fractal dimension correlated with the NPS‐peak frequency and was independent of noise magnitude, suggesting that the scalar metric of fractal dimension can be used to quantify the change in noise texture across reconstruction approaches. Results demonstrated that fractal dimension can be estimated from four, 64 × 64‐pixel ROIs or one 128 × 128 ROI within a head CT image, which may make it amenable for quantifying noise texture within clinical images
- …