25,602 research outputs found
Microfluidic polymerase chain reaction
We implement microfluidic technology to miniaturize a thermal cycling system for amplifying DNA fragments. By using a microfluidic thermal heat exchanger to cool a Peltier junction, we have demonstrated rapid heating and cooling of small volumes of solution. We use a miniature K-type thermocouple to provide a means for in situ sensing of the temperature inside the microrefrigeration system. By combining the thermocouple, two power supplies controlled by a relay system, and computer automation, we reproduce the function of a commercial polymerase chain reaction thermal cycler and demonstrate amplification of a DNA sample of about 1000 base pairs
Recommended from our members
Rapid Optical Cavity PCR.
Recent outbreaks of deadly infectious diseases, such as Ebola and Middle East respiratory syndrome coronavirus, have motivated the research for accurate, rapid diagnostics that can be administered at the point of care. Nucleic acid biomarkers for these diseases can be amplified and quantified via polymerase chain reaction (PCR). In order to solve the problems of conventional PCR--speed, uniform heating and cooling, and massive metal heating blocks--an innovative optofluidic cavity PCR method using light-emitting diodes (LEDs) is accomplished. Using this device, 30 thermal cycles between 94 °C and 68 °C can be accomplished in 4 min for 1.3 μL (10 min for 10 μL). Simulation results show that temperature differences across the 750 μm thick cavity are less than 2 °C and 0.2 °C, respectively, at 94 °C and 68 °C. Nucleic acid concentrations as low as 10(-8) ng μL(-1) (2 DNA copies per μL) can be amplified with 40 PCR thermal cycles. This simple, ultrafast, precise, robust, and low-cost optofluidic cavity PCR is favorable for advanced molecular diagnostics and precision medicine. It is especially important for the development of lightweight, point-of-care devices for use in both developing and developed countries
Multiplex STR amplification sensitivity in a silicon microchip
The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (mu PCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 mu l each. Diluted reference DNA samples (1 ng-31 pg) were amplified on the mu PCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both mu PCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis
Recommended from our members
Design of an innovative polymerase chain reaction device based on buoyancy driven flow
This paper was presented at the 2nd Micro and Nano Flows Conference (MNF2009), which was held at Brunel University, West London, UK. The conference was organised by Brunel University and supported by the Institution of Mechanical Engineers, IPEM, the Italian Union of Thermofluid dynamics, the Process Intensification Network, HEXAG - the Heat Exchange Action Group and the Institute of Mathematics and its Applications.Polymerase Chain Reaction (PCR) plays a central role in the field of molecular biology. The miniaturization of PCR systems is promising as it potentially minimizes costly reagent consumption and time
required for analysis. In PCR microdevices a sample solution is usually handled by external pumps. An alternative solution relies on temperature-induced density difference in the presence of a body force to
induce buoyancy driven flow. This alternative method is easy to be used and does not require expensive setup, but, to date, the thermo-fluid-dynamic field in the micro-channels still needs to be optimized. The present study focuses on the design of micro-channels, having innovative and optimized shapes to obtain proper fluid actuation and DNA sample amplification within buoyancy driven flow PCR devices. A parametric study is carried out by means of computational thermal fluid dynamic modeling: several channel geometry configurations were compared in terms of time required for analysis, temperature distribution and priming volume. The advantages and disadvantages of such configurations are discussed
Recommended from our members
Continuous Flow vs. Static Chamber μPCR Devices on Flexible Polymeric Substrates
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Two types of μPCR devices, a continuous flow and a static chamber device, fabricated on flexible polymeric substrates are compared in the current computational study. Laminar flow, heat transfer in both solid and fluid, mass conservation of species, and reaction kinetics of PCR are coupled using COMSOL. The comparison is performed under same conditions; same material stack (based on flexible polymeric films with integrated microheaters), same species initial concentrations, amplification of the same volume of fluid sample, and implementation of the same PCR protocol. Performance is quantified in terms of DNA amplification, energy consumption, and total operating time. The calculations show that the efficiency of DNA amplification is higher in the continuous flow device. However, the continuous flow device requires (~6 times) greater energy consumption which is justified by the smaller thermal mass of the static chamber device. As regards the speed, the total time required for the static chamber μPCR is comparable to the time for the continuous flow μPCR
Recommended from our members
Precision cancer monitoring using a novel, fully integrated, microfluidic array partitioning digital PCR platform.
A novel digital PCR (dPCR) platform combining off-the-shelf reagents, a micro-molded plastic microfluidic consumable with a fully integrated single dPCR instrument was developed to address the needs for routine clinical diagnostics. This new platform offers a simplified workflow that enables: rapid time-to-answer; low potential for cross contamination; minimal sample waste; all within a single integrated instrument. Here we showcase the capability of this fully integrated platform to detect and quantify non-small cell lung carcinoma (NSCLC) rare genetic mutants (EGFR T790M) with precision cell-free DNA (cfDNA) standards. Next, we validated the platform with an established chronic myeloid leukemia (CML) fusion gene (BCR-ABL1) assay down to 0.01% mutant allele frequency to highlight the platform's utility for precision cancer monitoring. Thirdly, using a juvenile myelomonocytic leukemia (JMML) patient-specific assay we demonstrate the ability to precisely track an individual cancer patient's response to therapy and show the patient's achievement of complete molecular remission. These three applications highlight the flexibility and utility of this novel fully integrated dPCR platform that has the potential to transform personalized medicine for cancer recurrence monitoring
Amplification efficiency and thermal stability of qPCR instrumentation: Current landscape and future perspectives
This is a final draft version of the publication following acceptance by the journal.Quantitative polymerase chain reaction (qPCR) is a method of amplifying and detecting small samples of genetic material in real time and is in routine use across many laboratories. Speed and thermal uniformity, two important factors in a qPCR test, are in direct conflict with one another in conventional peltier‑driven thermal cyclers. To overcome this, companies are developing novel thermal systems for qPCR testing. More recently, qPCR technology has developed to enable its use in point‑of‑care testing (POCT), where the test is administered and results are obtained in a single visit to a health provider, particularly in developing countries. For a system to be suitable for POCT it must be rapid and reliable. In the present study, the speed and thermal uniformity of four qPCR thermal cyclers currently available were compared, two of which use the conventional peltier/block heating method and two of which use novel heating and cooling methods
Recommended from our members
A portable device for nucleic acid quantification powered by sunlight, a flame or electricity.
A decentralized approach to diagnostics can decrease the time to treatment of infectious diseases in resource-limited settings. Yet most modern diagnostic tools require stable electricity and are not portable. Here, we describe a portable device for isothermal nucleic-acid quantification that can operate with power from electricity, sunlight or a flame, and that can store heat from intermittent energy sources, for operation when electrical power is not available or reliable. We deployed the device in two Ugandan health clinics, where it successfully operated through multiple power outages, with equivalent performance when powered via sunlight or electricity. A direct comparison between the portable device and commercial qPCR (quantitative polymerase chain reaction) machines for samples from 71 Ugandan patients (29 of which were tested in Uganda) for the presence of Kaposi's sarcoma-associated herpesvirus DNA showed 94% agreement, with the four discordant samples having the lowest concentration of the herpesvirus DNA. The device's flexibility in power supply provides a needed solution for on-field diagnostics
P53 tumour-suppressor gene mutations are mainly localised on exon 7 in human primary and metastatic prostate cancer.
Mutations in the p53 tumour-suppressor gene are among the most common genetic alterations in human cancers. In the present study we analysed the mutations in the p53 tumor-suppressor gene in 25 primary and 20 metastatic human prostate cancer specimens. DNA extracted from the paraffin-embedded sections was amplified by hot-start polymerase chain reaction, and p53 gene mutations in the conserved mid-region (exons 4-9) were examined using single-strand conformation polymorphism (SSCP) analysis and immunohistochemistry. In the present study, we used a novel hot-start PCR-SSCP technique using DNA Taq polymerase antibody, which eliminates primer-dimers and non-specific products. Because of this new technique, the results of PCR-SSCP showed very high resolution. Polymerase chain reaction products were sequenced directly for point mutations for the p53 gene. Mutations were found in 2 out of 25 primary prostate cancers (8%) and 4 out of 20 metastatic cancers (20%). Mutations were observed exclusively in exon 7 and not in exons 4, 5, 6, 8 or 9. Nuclear accumulation of p53 protein, determined by immunohistochemistry, correlated with the degree of metastasis in prostatic cancer
- …