1,166 research outputs found

    Multiphase PMSM and PMaSynRM flux map model with space harmonics and multiple plane cross harmonic saturation

    Get PDF
    © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.Multiphase Synchronous Machines vary in rotor construction and winding distribution leading to non-sinusoidal inductances along the rotor periphery. Moreover, saturation and cross-saturation effects make the precise modeling a complex task. This paper proposes a general model of multi-phase magnet-excited synchronous machines considering multi-dimensional space modeling and revealing cross-harmonic saturation. The models can predict multiphase motor behavior in any transient state, including startup. They are based on flux maps obtained from static 2D Finite-Element (FE) analysis. FE validations have been performed to confirm authenticity of the dynamic models of multiphase PMaSynRMs. Very close to FE precision is guaranteed while computation time is incomparably lower.Postprint (author's final draft

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Serangga dan mitos suku kaum jakun, Kampung Peta, Mersing Johor

    Get PDF
    This study focuses on seeing insects from the mythical perspective of the Orang Asli tribe of Jakun, Kampung Peta, Mersing Johor. The existence of insects in the life of every ethnic in Malaysia has brought various elements of myths. Therefore, when combining myths and insects, it could be said that myth is a human way of understanding, expressing and linking insects to him/herself as well as a group/culture. The practice of using insects among ethnic groups in daily life is called etnoentomology. In this study, the insects studied are the butterfly (Lepidoptera), the odonates (Odonata) and the cicadas (Homoptera). This is because these insects are very popular in the community and have their own myths that are brought into the local culture of belief

    Direct Torque Control of Permanent Magnet Synchronous Motor

    Get PDF
    Permanent Magnet Synchronous Motors (PMSM’s) are used in places that require fast torque response and high-performance operation of the machine. The Direct Torque Control (DTC) technique is different from methods which use current controllers in an proper reference frame to control the motor torque and fluxe values. The DTC technique does not any current controllers. DTC controls the Voltage source Inverter states on the basis of difference between the required and obtained torque and flux values. This is done by selecting one out of the six voltage vectors obtained by the Inverter (VSI) to have torque and flux fluctuations in between the limits of 2 hysteresis bands. This thesis obtains the modelling of the Direct Torque Control (DTC) system of PMSM using MATLAB/Simulink®. Speed control of PMSM using Field Oriented Control technique and Direct Torque Space Vector Pulse Width Modulation technique is also analysed and compared with traditional DTC. Simulation results are presented to help analyse the system performance and PI controller parameters influence on the system performance. The analysis is also done with fuzzy logic controller

    Field Oriented Sliding Mode Control of Surface-Mounted Permanent Magnet AC Motors: Theory and Applications to Electrified Vehicles

    Get PDF
    Permanent magnet ac motors have been extensively utilized for adjustable-speed traction motor drives, due to their inherent advantages including higher power density, superior efficiency and reliability, more precise and rapid torque control, larger power factor, longer bearing, and insulation life-time. Without any proportional-and-integral (PI) controllers, this paper introduces novel first- and higher-order field-oriented sliding mode control schemes. Compared with the traditional PI-based vector control techniques, it is shown that the proposed field oriented sliding mode control methods improve the dynamic torque and speed response, and enhance the robustness to parameter variations, modeling uncertainties, and external load perturbations. While both first- and higher-order controllers display excellent performance, computer simulations show that the higher-order field-oriented sliding mode scheme offers better performance by reducing the chattering phenomenon, which is presented in the first-order scheme. The higher-order field-oriented sliding mode controller, based on the hierarchical use of supertwisting algorithm, is then implemented with a Texas Instruments TMS320F28335 DSP hardware platform to prototype the surface-mounted permanent magnet ac motor drive. Last, computer simulation studies demonstrate that the proposed field-oriented sliding mode control approach is able to effectively meet the speed and torque requirements of a heavy-duty electrified vehicle during the EPA urban driving schedule

    Permanent-Magnet Synchronous Machine Drives

    Get PDF
    The permanent-magnet synchronous machine (PMSM) drive is one of best choices for a full range of motion control applications. For example, the PMSM is widely used in robotics, machine tools, actuators, and it is being considered in high-power applications such as industrial drives and vehicular propulsion. It is also used for residential/commercial applications. The PMSM is known for having low torque ripple, superior dynamic performance, high efficiency and high power density. Section 1 deals with the introduction of PMSM and how it is evolved from synchronous motors. Section 2 briefly discusses about the types of PMSM. Section 3 tells about the assumptions in PMSM for modeling of PMSM and it derives the equivalent circuit of PMSM. In Section 4, permanent magnet synchronous motor drive system is briefly discussed with explanation of each blocks in the systems. Section 5 reveals about the control techniques of PMSM like scalar control, vector control and simulation of PMSM driven by field-oriented control using fuzzy logic control with space vector modulation for minimizing torque ripples. PMSM control with and without rotor position sensors along with different control techniques for controlling various parameters of PMSM for different applications is presented in Section 6

    Modeling and analysis of field-oriented control based permanent magnet synchronous motor drive system using fuzzy logic controller with speed response improvement

    Get PDF
    The permanent magnet synchronous motor (PMSM) acts as an electrical motor mainly used in many diverse applications. The controlling of the PMSM drive is necessary due to frequent usage in various systems. The conventional proportional-integral-derivative (PID) controller’s drawbacks are overcome with fuzzy logic controller (FLC) and adopted in the PMSM drive system. In this manuscript, an efficient field-oriented control (FOC) based PMSM drive system using a fuzzy logic controller (FLC) is modeled to improve the speed and torque response of the PMSM. The PMSM drive system is modeled using abc to αβ and αβ to abc transformation, 2-level space vector pulse width modulation (SVPWM), AC to DC rectifier with an inverter, followed by PMSM drive, proportional integral (PI) controller along with FLC. The FLC’s improved fuzzy rule set is adopted to provide faster speed response, less % overshoot time, and minimal steady-state error of the PMSM drive system. The simulation results of speed response, torque response, speed error, and phase currents are analyzed. The FLC-based PMSM drive is compared with the conventional PID-based PMSM drive system with better improvements in performance metrics
    corecore